The induced polarization effects magnetic field measurement method based on the superconductive quantum interfere device (SQUID) and transient electromagnetic (TEM) system can improve the exploration accuracy of metal minerals. As the core component of the SQUID-TEM system based on magnetic source, the current transmitter should reach consensus in three key aspects: high power, controllable turn-off time and combined current waveforms. In order to solve the problem of single transmitting current waveform and uncontrollable turn-off time in traditional current transmitter, a topology structure of current transmitter with multiple waveform combinations in time domain is proposed in this paper. By using the passive multi-group clamp technology and RLC series resonance technology, the falling edge turn-off time of trapezoidal and triangular transmitting current can be controlled, and the pulse width of semi-sinusoidal transmitting current can be adjusted. The laboratory and field experiments are implemented to test the performance of the current transmitter. Compared with the commercial PROTEM67 transmitter, the test results show that it can successfully transmit three current waveforms and their combination waveforms, the current amplitude is more than 100A, and the transmitting current turn-off time is controllable. The field measurement response results show that the combined multi-waveform transmit system can effectively measure the induction field and the polarization field generated by the Cole-Cole polarization ring, which provides technical support for the high-precision detection of induction-polarization effects based on the SQUID-TEM system.
31 May 2023 in IEEE Transactions on Geoscience and Remote Sensing
With the improvement in the accuracy of time-domain electromagnetic method (TDEM) observations for geophysical exploration, abnormal diffusion phenomena have become a more salient focus of research. In particular, the induced polarization (IP) effect and magnetic viscosity (MV) effect are often observed in the exploration of polymetallic ore, with IP effect leading to a negative TDEM response, and MV effect generating a power-law decay of -0.6 to 1.4 in the late stage response. Ignoring these effects can lead to incorrect data interpretation. Therefore, to model and analyze both IP effect and MV effect accurately, a three-dimensional (3D) numerical modeling method for induced polarization and magnetic viscosity (IP-MV) effect is proposed. The Cole-Cole conductivity and Cole-Cole susceptibility models are approximated in the time domain using the Multiple-Zero-Pole (MZP) method. Then the diffusion equations for the electric and magnetization intensity fields are derived as control equations, while the 3D modeling of the IP-MV effect with full-waveform is realized based on the improved recursive convolution technique and finite-difference time-domain (FDTD) method. The effectiveness is verified by comparing with the one-dimensional (1D) numerical integration solutions. The response characteristics of IP effect and MV effect are analyzed with full trapezoidal waveform, and a complex model including IP-MV effect is discussed. It is demonstrated that IP-MV effect can be better observed at the on-time stage. The proposed method can effectively model the diffusion process of IP-MV effect with the full-waveform, which can be helpful for improving the inversion accuracy and detection precision for complex geological formations.
5 September 2022 in IEEE Transactions on Geoscience and Remote Sensing
Electromagnetic (EM) sounding methods in the time and frequency domains are widely used in polymetallic ore exploration and can measure both EM induction and induced polarization (IP) responses simultaneously. Depth inversion is a crucial factor affecting the accuracy of data interpretation. The effect of IP on EM wave propagation has been ignored in traditional studies of diffusion depth and skin depth. This article is based on the generalized effective-medium theory of the IP effect (GEMTIP) model to represent the IP effect. The frequency domain solution based on GEMTIP is obtained. To address the problem whereby the time-domain solution cannot be solved by inverse Laplace transform, rational approximation and linear programming methods are used to simulate the variation of pulse field source with time and distance. We analyze the influences of geometrical parameters and physical properties of rocks and ores with the IP effect on the depth. Finally, we consider the influence of intrinsic chargeability and improve the classic diffusion depth formula. The formulae for estimating the time-domain diffusion depth of the IP effect under certain conditions are given and verified. These methods are of great significance to better understand the relationship between the subsurface dispersive media and the propagation of EM waves.
27 March 2025 in IEEE Transactions on Power Electronics
In the context of the increasing global demand for renewable energy and the rapid development of large-scale photovoltaic (PV) power generation, efficient grid connection of PV energy has become crucial. However, existing grid-connected inverters (GCI) face issues such as high-power losses issue of inductive GCI (IGCI) or limited operating ranges issue of capacitive GCI (CGCI). This article introduces a multiple energy conversion channels fusion GCI (MC-FGCI) for large-scale PV power injection. First, MC-FGCI is proposed based on a new topology circuit configuration. Second, an equivalent circuit model of IGCI and CGCI is introduced to calculate the critical point for channel switching. The IGCI and CGCI efficient operating boundaries are determined based on the critical point. Third, based on the efficient operating boundaries, a finite state machine based method is proposed to choose the optimal VSI for high-efficiency grid connection. Finally, experimental results show that compared to previous multiple parallel IGCI (MP-IGCI), the proposed MC-FGCI saves around 11% power loss by eliminating the lossy dc/dc link. Compared to MP-CGCI, the proposed MC-FGCI expands the active power injection range under low maximum power point (MPP) voltage.
20 November 2024 in IEEE Transactions on Geoscience and Remote Sensing
The induced polarization (IP) and superparamagnetic (SPM) multi-effect fields are generated due to complex physical characteristics and parameter information of polymetallic particles in grounded-wire source time-domain electromagnetic (TDEM) detection. Recent studies show that the accurate observation of IP characteristics and elimination of SPM interference can improve TDEM interpretation accuracy effectively. However, it is difficult to realize the accurate recognition and effective observation of the multi-effect responses in the large range of non-uniform grounded-wire source signals. Therefore, in this study, the three-dimensional (3-D) modeling of IP and SPM effects in grounded-wire source TDEM is realized by introducing the fractional Cole-Cole conductivity and susceptibility models and establishing the double-curl electric field convolution matrices. The response characteristics of IP and SPM effects are analyzed and a three-component observational method of multi-effect is proposed. The effectiveness of the proposed method is verified by carrying out observation experiments of IP and SPM equivalent circuits. The results show that observing the magnetic field component parallel to the grounded-wire source can obtain IP and SPM response characteristics earlier, and observing the vertical component can reduce the interference of SPM effect while obtaining more obvious IP responses. Through the comprehensive analysis of three-component responses, the IP and SPM characteristics can be better determined. This study has a guiding role in receiving the information of multi-effect responses and improving the accuracy of polymetallic ore detection.
25 December 2025 in IEEE Transactions on Instrumentation and Measurement
The superposition of the primary field in time-domain electromagnetic (TDEM) surveys can severely degrade data quality, especially during the early stage after the transmitting current is turned off, resulting in shallow detection blind spots. To address this problem, this paper proposes a cm-level coil–based method for equivalent measurement and removal of the primary field. By driving the cm-level coil with a proportionally reduced current, an equivalent primary field is generated while the induced secondary field remains negligible. The receiving system directly measures this equivalent primary field, enabling its subtraction from the observational data. The method was validated through field experiments using 4 m × 4 m and 50 m × 50 m transmitting coils, where residual primary fields from the bucking device and the complete primary field of the large loop were effectively removed. Consequently, the effective observation window was extended by 150 μs and 278 μs, respectively. The method significantly enhances shallow detection capability and exhibits broad applicability across TDEM system scales.