Several experiments are conducted to investigate the seismic behavior of composite shear walls because of their advantages compared to traditional reinforced concrete (RC) walls. However, the numerical studies are limited due to the complexities for the steel and concrete behaviors and their interaction. This paper presents a numerical study of composite shear walls with stiffened steel plates and infilled concrete (CWSC) using ABAQUS. The mechanical mechanisms of the web plate and concrete are studied. FE models are used to conduct parametric analysis to study the law of parameters on the seismic behaviour. The finite element (FE) model shows good agreement with the test results, including the hysteresis curves, failure phenomenon, ultimate strength, initial stiffness, and ductility. The web plate and concrete are the main components to resist lateral force. The web plate is found to contribute between 55% and 85% of the lateral force of wall. The corner of web plate mainly resists the vertical force, and the rest of web plate resists shear force. The concrete is separated into several columns by stiffened plates, each of which is independent and resisted vertical force. The wall thickness, steel ratio, and shear span ratio have the greatest influence on ultimate bearing capacity and elastic stiffness. The shear span ratio and axial compression ratio have the greatest influence on ductility. The test and analytical results are used to propose formulas to evaluate the ultimate strength capacity and stiffness of the composite shear wall under cyclic loading. The formulas could well predict the ultimate strength capacity reported in the literature.
Wind tunnel test results can be influenced by various factors such as the blockage ratio and scaling ratio. These factors may introduce errors in the experimental outcomes, impacting the accuracy and reliability of the data obtained. This study quantitatively assesses consistency and identifies uncertainty sources to enhance result uniformity across various wind tunnel laboratories. This study conducted a systematic comparison between different wind tunnels in terms of rigid model pressure measurement wind tunnel experiments on the same Commonwealth Advisory Aeronautical Research Council (CAARC) standard tall building model. The study analyzes and discusses the results of mean and root-mean-square (RMS) wind pressure coefficients, peak factors, extreme wind pressure coefficients, probability density distributions, and base overturning force coefficients. The results indicated that in the open-circuit wind tunnel laboratory, the mean wind pressure coefficient is underestimated in the positive pressure region and overestimated in the negative pressure region. This is due to the static pressure which significantly decreases the streamwise direction within the test section, and the difference in static pressure is logarithmically proportional to the mean wind speed. Additionally, dynamic pressure is uniformly distributed along the test section axis. The inaccurate measurement of static pressure leads to these results. To address this issue, an indirect measurement method was employed to correct the static pressure results and reduce the error in the mean wind pressure coefficient to within 10%. Furthermore, differences in turbulence integral scale result in an error of up to 16% in the RMS wind pressure coefficient. Therefore, when conducting rigid model pressure measurement wind tunnel experiments, especially in open-circuit wind tunnel laboratories, careful consideration should be given to the influence of static pressure drop and integral length scale of turbulence.