28 March 2025 in Magnetic Resonance in Medicine
Purpose: To compare 0.55 T and 3 T MRI for imaging patients with titanium total hip arthroplasty (THA). Patients with orthopedic metallic implants often require diagnostic imaging to evaluate adjacent tissues. MRI performance measures, including artifact levels and SNR, vary with field strength. Methods: Six patients with titanium THA were scanned with similar protocols at 0.55 T and 3 T, including proton density (PD) weighted turbo spin echo (TSE), PD TSE with view‐angle tilting (TSE + VAT), PD slice encoding for metal artifact correction (SEMAC), and short tau inversion recovery with SEMAC (STIR‐SEMAC). Images from both field strengths were scored by two readers and qualitatively and quantitatively compared. Results: Diagnostic confidence was significantly higher at 0.55 T compared to 3 T. Perceived metal artifact was substantially reduced at 0.55 T compared to 3 T. At 0.55 T, diagnostic imaging was achieved both without and with multi spectral imaging (MSI) for PD weighted images. Conclusion: Compared to 3 T, 0.55 T MRI offers substantially reduced metal artifacts and higher diagnostic confidence when imaging titanium THA. Advanced multi‐spectral techniques may not be required when the metallic components are entirely titanium.
5 August 2021 in IEEE Transactions on Medical Imaging
Balanced steady-state free precession (bSSFP) imaging enables high scan efficiency in MRI, but differs from conventional sequences in terms of elevated sensitivity to main field inhomogeneity and nonstandard ${\text {T}}_{{2}}/{\text {T}}_{{1}}$ -weighted tissue contrast. To address these limitations, multiple bSSFP images of the same anatomy are commonly acquired with a set of different RF phase-cycling increments. Joint processing of phase-cycled acquisitions serves to mitigate sensitivity to field inhomogeneity. Recently phase-cycled bSSFP acquisitions were also leveraged to estimate relaxation parameters based on explicit signal models. While effective, these model-based methods often involve a large number of acquisitions (N ≈ 10-16), degrading scan efficiency. Here, we propose a new constrained ellipse fitting method (CELF) for parameter estimation with improved efficiency and accuracy in phase-cycled bSSFP MRI. CELF is based on the elliptical signal model framework for complex bSSFP signals; and it introduces geometrical constraints on ellipse properties to improve estimation efficiency, and dictionary-based identification to improve estimation accuracy. CELF generates maps of ${\text {T}}_{{1}}$ , ${\text {T}}_{{2}}$ , off-resonance and on-resonant bSSFP signal by employing a separate $\text {B}_{{1}}$ map to mitigate sensitivity to flip angle variations. Our results indicate that CELF can produce accurate off-resonance and banding-free bSSFP maps with as few as N = 4 acquisitions, while estimation accuracy for relaxation parameters is notably limited by biases from microstructural sensitivity of bSSFP imaging.
2 October 2025 in Magnetic Resonance in Medicine
Purpose: To evaluate a hexagonal sampling approach for accelerated slice encoding for metal artifact correction (SEMAC) at 0.55 T. Contemporary mid‐field systems (0.1 T–1.0 T) show tremendous potential for imaging near metal implants. However, the limited parallel‐imaging options necessitate alternative methods for scan time reduction. Methods: We apply retrospective hexagonal undersampling to current state‐of‐the‐art SEMAC with 2‐fold generalized autocalibrating partially parallel acquisitions–based parallel imaging at 0.55 T. The hexagonal sampling approach results in an additional 50% scan time reduction. Feasibility is evaluated with phantom experiments involving spinal fixation and total hip arthroplasty hardware, and in vivo experiments involving patients with spinal fusions with varying compositions and 1 volunteer with a total hip arthroplasty. Results: Hexagonal sampling provides an additional 50% scan time reduction with compatible image quality. The two tradeoffs are (i) a small increase in signal void due to the loss of signal from one SEMAC spectral bin during post‐acquisition filtering and (ii) position‐dependent signal‐to‐noise‐ratio reduction at locations close to the edge of the field of view in the phase‐encoding direction. Conclusion: We demonstrate that hexagonal sampling can provide 50% scan time reduction in addition to generalized autocalibrating partially parallel acquisitions/parallel imaging for SEMAC at 0.55 T without introducing substantial artifacts. This may be a valuable mechanism for reducing scan time at 0.55 T and other midfield strengths, where parallel‐imaging acceleration is limited.
3 November 2025 in Magnetic Resonance in Medicine
Purpose: The increasing prevalence of orthopedic metallic implants necessitates optimization of MRI methods to monitor surrounding tissues and identify complications. The emergence of contemporary mid‐ and low‐field systems as promising platforms for imaging around metal requires development of new protocols optimized for these field strengths. Motivated by these, we develop a simulation framework that predicts MRI performance near metallic implants, considering B0 field strength and multi‐spectral imaging (MSI) parameters. Methods: A simulation framework for imaging near metal incorporating 3D implant and 3D human anatomical models, and imaging and sequence parameters is developed. MSI acquisitions are simulated based on susceptibility‐induced field shifts. Validation is performed using phantom and in vivo experiments at 0.55 and 3 T, comparing simulated and experimental images for artifact shape and SNR. Performance is demonstrated by evaluating impacts of field strength, spectral bins, RF and readout bandwidths, and implant materials. Results: Simulations accurately reproduced experimental imaging performance, with extent and patterns of metal artifacts closely matching experimental observations at both 0.55 and 3 T, while correctly predicting increased SNR and artifact size with increasing field strength. The framework demonstrated the impact of field strength, spectral bins, RF and readout bandwidths, and implant material on metal artifacts and image quality. Conclusion: This open‐source simulation framework effectively predicts MRI performance near metallic implants. This can facilitate protocol optimization and exploration of imaging parameters without extensive/costly in vivo experiments. This tool can enable researchers to predict imaging performance for various implants across different field strengths, potentially accelerating development of optimized protocols for clinical use.
20 June 2026 in Journal of Magnetic Resonance Imaging