Bochao Li

Dr. Bochao Li

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MBMathieu Boudreau
Mathieu Boudreau
AKAgah Karakuzu
Agah Karakuzu
JCJulien Cohen‐Adad
Julien Cohen‐Adad
EBEcem Bozkurt
Ecem Bozkurt
MCMadeline Carr
Madeline Carr
TGthe ISMRM Reproducible Research Study Group and the ISMRM Quantitative MR Study Group
the ISMRM Reproducible Research Study Group and the ISMRM Quantitative MR Study Group
Purpose: T1 mapping is a widely used quantitative MRI technique, but its tissue‐specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well‐established inversion‐recovery T1 mapping technique, using acquisition details from a seminal T1 mapping paper on a standardized phantom and in human brains.Methods: The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open‐source platforms. Intersubmission and intrasubmission comparisons were performed.Results: Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also developed: https://rrsg2020.dashboards.neurolibre.org.Conclusion: The T1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T1 variations in vivo.

20 November 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BLBochao Li
Bochao Li
NLNam G. Lee
Nam G. Lee
SCSophia X. Cui
Sophia X. Cui
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To determine R2 and transverse relaxation rates in healthy lung parenchyma at 0.55 T. This is important in that it informs the design and optimization of new imaging methods for 0.55T lung MRI.Methods: Experiments were performed in 3 healthy adult volunteers on a prototype whole‐body 0.55T MRI, using a custom free‐breathing electrocardiogram‐triggered, single‐slice echo‐shifted multi‐echo spin echo (ES‐MCSE) pulse sequence with respiratory navigation. Transverse relaxation rates R2 and and off‐resonance ∆f were jointly estimated using nonlinear least‐squares estimation. These measurements were compared against R2 estimates from T2‐prepared balanced SSFP (T2‐Prep bSSFP) and estimates from multi‐echo gradient echo, which are used widely but prone to error due to different subvoxel weighting.Results: The mean R2 and values of lung parenchyma obtained from ES‐MCSE were 17.3 ± 0.7 Hz and 127.5 ± 16.4 Hz (T2 = 61.6 ± 1.7 ms; = 9.5 ms ± 1.6 ms), respectively. The off‐resonance estimates ranged from −60 to 30 Hz. The R2 from T2‐Prep bSSFP was 15.7 ± 1.7 Hz (T2 = 68.6 ± 8.6 ms) and from multi‐echo gradient echo was 131.2 ± 30.4 Hz ( = 8.0 ± 2.5 ms). Paired t‐test indicated that there is a significant difference between the proposed and reference methods (p < 0.05). The mean R2 estimate from T2‐Prep bSSFP was slightly smaller than that from ES‐MCSE, whereas the mean and estimates from ES‐MCSE and multi‐echo gradient echo were similar to each other across all subjects.Conclusions: Joint estimation of transverse relaxation rates and off‐resonance is feasible at 0.55 T with a free‐breathing electrocardiogram‐gated and navigator‐gated ES‐MCSE sequence. At 0.55 T, the mean R2 of 17.3 Hz is similar to the reported mean R2 of 16.7 Hz at 1.5 T, but the mean of 127.5 Hz is about 5–10 times smaller than that reported at 1.5 T.

28 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
KKKübra Keskin
Kübra Keskin
SCSophia X. Cui
Sophia X. Cui
BLBochao Li
Bochao Li
JGJordan S. Gross
Jordan S. Gross
JAJay Acharya
Jay Acharya
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To compare 0.55 T and 3 T MRI for imaging patients with titanium total hip arthroplasty (THA). Patients with orthopedic metallic implants often require diagnostic imaging to evaluate adjacent tissues. MRI performance measures, including artifact levels and SNR, vary with field strength. Methods: Six patients with titanium THA were scanned with similar protocols at 0.55 T and 3 T, including proton density (PD) weighted turbo spin echo (TSE), PD TSE with view‐angle tilting (TSE + VAT), PD slice encoding for metal artifact correction (SEMAC), and short tau inversion recovery with SEMAC (STIR‐SEMAC). Images from both field strengths were scored by two readers and qualitatively and quantitatively compared. Results: Diagnostic confidence was significantly higher at 0.55 T compared to 3 T. Perceived metal artifact was substantially reduced at 0.55 T compared to 3 T. At 0.55 T, diagnostic imaging was achieved both without and with multi spectral imaging (MSI) for PD weighted images. Conclusion: Compared to 3 T, 0.55 T MRI offers substantially reduced metal artifacts and higher diagnostic confidence when imaging titanium THA. Advanced multi‐spectral techniques may not be required when the metallic components are entirely titanium.


2 October 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BBBahadır Alp Barlas
Bahadır Alp Barlas
KKKübra Keskin
Kübra Keskin
BLBochao Li
Bochao Li
BHBrian A. Hargreaves
Brian A. Hargreaves
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To evaluate a hexagonal sampling approach for accelerated slice encoding for metal artifact correction (SEMAC) at 0.55 T. Contemporary mid‐field systems (0.1 T–1.0 T) show tremendous potential for imaging near metal implants. However, the limited parallel‐imaging options necessitate alternative methods for scan time reduction. Methods: We apply retrospective hexagonal undersampling to current state‐of‐the‐art SEMAC with 2‐fold generalized autocalibrating partially parallel acquisitions–based parallel imaging at 0.55 T. The hexagonal sampling approach results in an additional 50% scan time reduction. Feasibility is evaluated with phantom experiments involving spinal fixation and total hip arthroplasty hardware, and in vivo experiments involving patients with spinal fusions with varying compositions and 1 volunteer with a total hip arthroplasty. Results: Hexagonal sampling provides an additional 50% scan time reduction with compatible image quality. The two tradeoffs are (i) a small increase in signal void due to the loss of signal from one SEMAC spectral bin during post‐acquisition filtering and (ii) position‐dependent signal‐to‐noise‐ratio reduction at locations close to the edge of the field of view in the phase‐encoding direction. Conclusion: We demonstrate that hexagonal sampling can provide 50% scan time reduction in addition to generalized autocalibrating partially parallel acquisitions/parallel imaging for SEMAC at 0.55 T without introducing substantial artifacts. This may be a valuable mechanism for reducing scan time at 0.55 T and other midfield strengths, where parallel‐imaging acceleration is limited.

17 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ZZZiwei Zhao
Ziwei Zhao
NLNam G. Lee
Nam G. Lee
BTBilal Tasdelen
Bilal Tasdelen
XMXin Miao
Xin Miao
YTYe Tian
Ye Tian
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To develop a free‐breathing pulmonary imaging technique that provides three‐dimensional ( 3D) structural images and regional ventilation maps, and to evaluate its repeatability and accuracy compared with two‐dimensional phase‐resolved functional lung ( PREFUL ) and global tidal volume. Methods: A free‐breathing 3D stack‐of‐spiral out‐in ( SOS out‐in) balanced steady‐state free precession (bSSFP) sequence with self‐navigators was designed to achieve 2‐mm isotropic resolution in 5 min. Respiratory‐resolved images were reconstructed using spatial L1 wavelet and temporal finite‐difference constraints. The 3D ventilation maps were generated based on Jacobian determinant of the estimated nonrigid deformations. Six healthy volunteers were scanned in supine and prone positions. Ventilation maps were compared with two‐dimensional PREFUL from two matched slices. Test–retest repeatability was assessed using Bland–Altman analysis. Correlations among the proposed method, PREFUL, and global tidal volume were evaluated. Results: In healthy volunteers, the SOS out‐in lung images provided sufficient vessel‐parenchyma contrast and boundary sharpness to support accurate ventilation estimation. Regional ventilation measurements from 3D SOS out‐in demonstrated good repeatability (relative differences < 10%). Ventilation maps from 3D SOS out‐in strongly correlated with PREFUL on a slice‐matched basis as well as with global tidal volume ( R 2 > 0.7, p < 0.001). Conclusion: The proposed method provides high‐quality respiratory‐resolved structural images and 3D ventilation mapping in a single 5‐min scan at 0. 55 T . Ventilation measurements are sensitive, consistent, and in good agreement with PREFUL and spirometry.