15 April 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
In this article, we investigate quantum entanglement (QE) filtering to address the challenges in multi-isotope positron emission tomography (PET) or in PET studies utilizing radiotracers with dual-positron and prompt gamma emissions. Via GATE simulation, we demonstrate the efficacy of QE filtering using a one-of-a-kind cadmium zinc telluride (CZT) PET system. establishing its viability as a multimodal scanner and ability to perform QE filtering. We show the high Compton scattering probability in this CZT-based scanner with 44.2% of gammas undergoing a single scatter prior to absorption. Additionally, the overall system sensitivity as a standard PET scanner (11.29%), QE-PET scanner (6.81%), and Compton Camera (11.29%) is quantified. Further, we find a 23% decrease in the double Compton scatter (DCSc) frequency needed for QE filtering for each mm decrease in crystal resolution and an increase in mean absolute error (MAE) of their δθs from 6.8∘ for 1 mm resolution to 9.5∘, 12.2∘, and 15.3∘ for 2, 4, and 8 mm resolution, respectively. These results reinforce the potential of CZT detectors to lead next generation PET systems taking full advantage of the QE information of positron annihilation photons.
17 December 2024 in Bio-Algorithms and Med-Systems
Objective: We assess the viability of using quantum entanglement (QE) information for improving event classification in a combined PET-Compton Camera (PET-CC) system, particularly in the potential for distinguishing true positron annihilation events from Random events due to prompt gamma contamination for β+ and γ emitting isotopes. Methods: Monte Carlo GATE simulations were performed to evaluate the sensitivity and accuracy of event classification in various scenarios using ground truth data, including standard PET events and Compton Camera interactions. QE-sensitive data subsets were identified and filtered based on either polar scattering angles (θ) or the energy of the initial Compton scatter (EC). The enhancement ratio – ratio of the difference of azimuthal scattering at Δφ = 90 and 0 – and fraction of post-filter Trues were used as metrics. Results: The simulations showed that QE information could assist in resolving energy ambiguities, particularly in cases where prompt gamma emissions complicate event pairing. Filtering based on EC provided a higher enhancement ratio (R ≈ 1.8) compared to θ-based filtering (R ≈ 1.4), indicating better discrimination between True and Random events. The ratio of Trues to Total events passing the EC filter (0.837) greatly improved upon that of the θ-based filter (0.541). Conclusions: Our results suggest that energy-based filtering is more effective in leveraging QE information, but further refinement of filtering algorithms is needed to fully realize its benefits. While QE has the potential to improve event classification in PET-CC systems for a few coincidence cases, further studies are needed to utilize this paradigm in image formation.
14 June 2024 in Advances in Radiotherapy & Nuclear Medicine
The key metrics for positron emission tomography (PET) imaging devices include the capability to capture the maximum available amount of annihilation photon information while generating high-quality images of the radiation distribution. This capability carries clinical implications by reducing scanning time for imaging, thus reducing radiation exposure for patients. However, imaging quality is degraded by positron range effects and the non-collinearity of positron annihilation photons. Utilizing an edge-on configuration of cadmium zinc telluride (CZT) detector crystals offers a potential solution to increase PET sensitivity. The high cross-section of CZT and its capacity to detect both 511 keV annihilation gammas and high-energy prompt gammas, along with multiple photon interaction events, contribute to this increased sensitivity. In this study, we propose a dual-panel edge-on CZT detector system comprised of 4 × 4 × 0.5 cm3 CZT detectors, with panel dimensions of 20 × 15 cm2 and a thickness of 4 cm. In this study, we demonstrate the increased sensitivity of our imaging system due to the detection of the Compton kinematics of high-energy gammas originating from prompt-gamma-emitting isotopes. This was achieved using Monte Carlo simulations of a prompt-gamma-emitting isotope,72As, with mean positron ranges >3 mm. Our system’s dynamic energy range, capable of detecting gammas up to 1.2 MeV, allows it to operate in a dual-mode fashion as both a Compton camera (CC) and standard PET. By presenting reconstructions of 72As, we highlight the absence of positron range effects in CC reconstructions compared to PET reconstructions. In addition, we evaluate the system’s increased sensitivity resulting from its ability to detect high-energy prompt gammas.
1 July 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
In a detector system where the number of channels exceeds the number of channels available on an application-specific integrated circuit (ASIC), there is a need to configure channels among multiple ASICs to achieve the lowest electronic noise and highest count rate. In this work, two board configurations were designed to experimentally assess which one provides the more favorable performance. In the half-half configuration, contiguous channels from one edge to the center of CZT detector are read by one ASIC, and the other half are read by the other ASIC. In the alternate configuration, the CZT channels are read by alternating ASICs. A lower electronic noise level, better FWHM energy resolution performance ( 5.35% ± 1.08% compared to 7.84% ± 0.98%), and higher count rate was found for the anode electrode strips with half-half configuration. Cross-talk between ASICs and deadtime play a role in the different performances, and the total count rate of the half-half configuration has a count rate 18.1% higher than that of the alternate configuration.