Emily Enlow

Emily Enlow

Auto-generated profile, based on publicly available information

Emily Enlow

Department of Electrical and Computer Engineering, University of California at Santa Cruz, Santa Cruz, CA, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2023 in Frontiers in Physics
Verified
Journal Article
Open access
EEEmily Enlow
Emily Enlow
SAShiva Abbaszadeh
Shiva Abbaszadeh
Single photon emission computed tomography (SPECT) and positron emission tomography (PET) are established medical imaging modalities that have been implemented for decades, but improvements in detector design and camera electronics are needed for advancement of both imaging technologies. Detectors are arguably the most important aspect of the systems. Similar to SPECT, PET typically relies on indirect conversion of gamma radiation via scintillators coupled with photosensors used to convert optical photons produced by the scintillator into an electrical signal. PET detectors are defined by their energy resolution, timing resolution, and spatial resolution, all of which affect and determine the image quality. Improvements in energy resolution have been shown by increasing the brightness of the scintillator utilizing materials like cerium bromide (CeBr3) or switching to a direct conversion detector, such as cadmium zinc telluride (CZT) or thallium bromide (TlBr). Timing resolution for PET is a focal point of the current research. Improving the timing resolution improves the signal-to-noise of the PET system and is integral to the implementation of time-of-flight PET. By utilizing novel configurations, such as side readouts on scintillators, timing resolution has been improved dramatically. Similarly, metascintillators, which use complex combinations for the scintillator material, have also shown improvements to the timing resolution. Additional research has focused on using Cherenkov light emission in scintillators to further improve the timing resolution. Other research is focused on using convolutional neural networks and other signal processing to enhance timing resolution. Lastly, aside from acollinearity and positron range, spatial resolution is impacted by the PET detector, therefore improving the intrinsic spatial resolution of the detector will allow for smaller features to be imaged. One method for improving the spatial resolution is to use unique configurations with layered scintillators. Additionally, monolithic scintillators have also been shown to have reduced spatial resolution. The future for both SPECT and PET image system advancement will depend on continued development of the detectors via many different pathways including materials, signal processing, physics, and novel configurations. In this review article, we will discuss challenges and emerging technologies for state-of-the-art radiation detectors utilized in PET and SPECT.

22 March 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
EEEmily Enlow
Emily Enlow
MDMilad Diba
Milad Diba
JCJames Clayton
James Clayton
BHBrian Harris
Brian Harris
SAShiva Abbaszadeh
Shiva Abbaszadeh
Cadmium zinc telluride (CZT) detectors enable high spatial resolution and high detection efficiency and are utilized for many gamma-ray and X-ray spectroscopy applications. In this article, we describe a stable bonding process and report on the characterization of cross-strip CZT detectors before and after bonding to flexible circuit. The bonding process utilizes gold stud bonding and polymer epoxy technique to bond the flexible circuits to two CZT crystals and form a detector module in an anode-cathode-cathode-anode (ACCA) configuration. The readout electronics is optimized in terms of shaper setting and steering electrode voltage. The average full-width half maximum (FWHM) energy resolution at 662 KeV of 110 CZT crystals tested individually was 3.5% ± 0.59% and 4.75% ± 0.48% prebonded and post-bonded, respectively. No depth correction was performed in this study. The average FWHM energy resolution at 662 KeV of the scaled-up system with 80 CZT crystals was 4.40% ± 0.53%, indicating the scaled-up readout electronics and stacking of the modules does not deteriorate performance. The proper shielding and grounding of the scaled-up system slightly improved the system-wide performance. The FWHM energy resolution at 511 KeV of the scaled-up system was 5.85% ± 0.73%.

15 April 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
GRGregory Romanchek
Gregory Romanchek
GSGreyson Shoop
Greyson Shoop
Kimia GholamiKimia Gholami
Kimia Gholami
EEEmily Enlow
Emily Enlow
SAShiva Abbaszadeh
Shiva Abbaszadeh
In this article, we investigate quantum entanglement (QE) filtering to address the challenges in multi-isotope positron emission tomography (PET) or in PET studies utilizing radiotracers with dual-positron and prompt gamma emissions. Via GATE simulation, we demonstrate the efficacy of QE filtering using a one-of-a-kind cadmium zinc telluride (CZT) PET system. establishing its viability as a multimodal scanner and ability to perform QE filtering. We show the high Compton scattering probability in this CZT-based scanner with 44.2% of gammas undergoing a single scatter prior to absorption. Additionally, the overall system sensitivity as a standard PET scanner (11.29%), QE-PET scanner (6.81%), and Compton Camera (11.29%) is quantified. Further, we find a 23% decrease in the double Compton scatter (DCSc) frequency needed for QE filtering for each mm decrease in crystal resolution and an increase in mean absolute error (MAE) of their δθs from 6.8∘ for 1 mm resolution to 9.5∘, 12.2∘, and 15.3∘ for 2, 4, and 8 mm resolution, respectively. These results reinforce the potential of CZT detectors to lead next generation PET systems taking full advantage of the QE information of positron annihilation photons.

1 July 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
EEEmily Enlow
Emily Enlow
YWYuli Wang
Yuli Wang
GSGreyson Shoop
Greyson Shoop
SAShiva Abbaszadeh
Shiva Abbaszadeh
In a detector system where the number of channels exceeds the number of channels available on an application-specific integrated circuit (ASIC), there is a need to configure channels among multiple ASICs to achieve the lowest electronic noise and highest count rate. In this work, two board configurations were designed to experimentally assess which one provides the more favorable performance. In the half-half configuration, contiguous channels from one edge to the center of CZT detector are read by one ASIC, and the other half are read by the other ASIC. In the alternate configuration, the CZT channels are read by alternating ASICs. A lower electronic noise level, better FWHM energy resolution performance ( 5.35% ± 1.08% compared to 7.84% ± 0.98%), and higher count rate was found for the anode electrode strips with half-half configuration. Cross-talk between ASICs and deadtime play a role in the different performances, and the total count rate of the half-half configuration has a count rate 18.1% higher than that of the alternate configuration.

8 July 2024 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
KHKaitlin Hellier
Kaitlin Hellier
EEEmily Enlow
Emily Enlow
SMSeyedehnajmeh Montazeri
Seyedehnajmeh Montazeri
MEMina Esmaeelpour
Mina Esmaeelpour
SAShiva Abbaszadeh
Shiva Abbaszadeh
Amorphous selenium (a-Se) is a promising semiconductor for a variety of photoconductive applications, predominantly in X-ray detection. In addition, material properties introduce several other potential applications in nonlinear optics. Photodarkening (PD) presents an interesting area of study; when exposed to band-region light, metastable structural changes induce a shift in the band edge and increase tail absorption. In this work, we investigate these effects utilizing a near-infrared (NIR) probe to avoid generating any darkening during beam transmission. We observe an unexpected result; here, we present the effects of band region exposure in NIR transmission (1570 nm). We observe a shift from darkening to lightening as the angle of incidence changes and compare PD with a red probe (633 nm), which does not exhibit this same phenomenon. We discuss the possible mechanisms and the next steps in delving into the physics underlying this behavior. These effects have strong implications for applications in nonlinear optics, memory, and sensing in the NIR.

3 April 2023 in Proceedings of SPIE
Verified
Conference Paper
Open access
ENEmmanouil Nikolakakis
Emmanouil Nikolakakis
GRGregory Romanchek
Gregory Romanchek
EEEmily Enlow
Emily Enlow
SAShiva Abbaszadeh
Shiva Abbaszadeh
Quantum entanglement provides an innovative approach to subtracting noise from the reconstructed image. We are studying the presence of correlated back-to-back gamma rays on a dual panel detector which utilizes the cadmium zinc telluride (CZT) cross strip configuration. This is performed by plotting the relative azimuthal angle of DCSc events and identifying regions that correspond to the entangled pairs of gammas. Our goal is to obtain a profile for scatter and random background and subtract it from the true image.