Geoffrey William Rodgers

Geoffrey William Rodgers

Auto-generated profile, based on publicly available information

Geoffrey William Rodgers

Department of Mechanical Engineering University of Canterbury Christchurch New Zealand

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2008 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
GRGeoffrey W. Rodgers
Geoffrey W. Rodgers
KSKevin M. Solberg
Kevin M. Solberg
JCJ. Geoffrey Chase
J. Geoffrey Chase
JMJohn B. Mander
John B. Mander
BBBrendon A. Bradley
Brendon A. Bradley
LLLuoman Li
Luoman Li

6 July 2021 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
RHRichard S. Henry
Richard S. Henry
YZYing Zhou
Ying Zhou
YLYiqiu Lu
Yiqiu Lu
GRGeoffrey W. Rodgers
Geoffrey W. Rodgers
AGAnqi Gu
Anqi Gu
Tony YangTony Yang
Tony Yang

1 January 2016 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JBJ. Borzouie
J. Borzouie
GMG. A. MacRae
G. A. MacRae
JCJ. G. Chase
J. G. Chase
GRG. W. Rodgers
G. W. Rodgers
GCG. Charles Clifton
G. Charles Clifton
This paper describes experimental testing of an asymmetric friction connection (AFC) at the base of a steel column such as may be used in a moment-frame. Friction/sliding surfaces were parallel to the column-strong axis. In-plane, out-of-plane and 2D clover leaf–cyclic tests were conducted of columns both with and without applied axial force. Tests were conducted both with and without bolts passing through the plates to provide compression on the sliding/friction interface. It was found that this type of rocking base–friction connection can tolerate high levels of drift without significant strength degradation, although some stiffness degradation occurred, especially after the cycles in the weak-axis direction. A simple procedure proposed to estimate the moment resistance is verified. The friction-base connections, having similar cost to conventional connections and exhibiting low-damage performance, have the potential to become widely used in aseismic construction.

1 March 2012 in Journal of Structural Engineering
Verified
Journal Article
Closed access
GRGeoffrey W. Rodgers
Geoffrey W. Rodgers
KSKevin M. Solberg
Kevin M. Solberg
John B ManderJohn B Mander
John B Mander
JCJ. Geoffrey Chase
J. Geoffrey Chase
BBBrendon A. Bradley
Brendon A. Bradley
RDRajesh P. Dhakal
Rajesh P. Dhakal
An experimental and computational study of an 80-percent scale precast concrete 3D beam-column joint subassembly designed with high force-to-volume (HF2V) dampers and damage-protected rocking connections is presented. A prestress system is implemented using high-alloy high-strength unbonded thread-bars through the beams and columns. The thread-bars are posttensioned and supplemental energy dissipation is provided by internally mounted lead-extrusion dampers. A multilevel seismic performance assessment (MSPA) is conducted considering three performance objectives related to occupant protection and collapse prevention. First, bidirectional quasi-static cyclic tests characterise the specimen’s performance. Results are used in a 3D nonlinear incremental dynamic analysis (IDA), to select critical earthquakes for further bidirectional experimental tests. Thus, quasi-earthquake displacement tests are performed by using the computationally predicted seismic demands corresponding to these ground motions. Resulting damage to the specimen is negligible, and the specimen satisfies all performance objectives related to serviceability, life-safety, and collapse prevention.

1 November 2009 in Journal of Structural Engineering
Verified
Journal Article
Closed access
TMThomas J. Mander
Thomas J. Mander
GRGeoffrey W. Rodgers
Geoffrey W. Rodgers
JCJ. Geoffrey Chase
J. Geoffrey Chase
John B ManderJohn B Mander
John B Mander
GMGregory A. MacRae
Gregory A. MacRae
RDRajesh P. Dhakal
Rajesh P. Dhakal
Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beam-column joint region consists of a top flange-hung beam connected to the column by an angle bracket. High-force-to-volume (HF2V) devices are attached from the column to the beam to provide joint rigidity and energy dissipation as the joint opens and closes. The HF2V devices are connected either below the beam flange or concealed above the beam’s lower flange. Reversed cyclic lateral load tests are conducted with drift amplitudes up to 4%. No damage is observed in the principal beam and column structural elements. The need for stiff device connections to achieve optimal device performance is demonstrated, and potential design solutions presented. Stable hysteresis and repeatable energy dissipation for a large number of cycles up to the 4% drift level is observed. It is concluded that superior and repeatable energy dissipation without damage can be achieved for every dynamic motion cycle, in contrast to conventional sacrificially designed welded moment frame connections.

1 September 2015 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
JBJ. Borzouie
J. Borzouie
GMG.A. MacRae
G.A. MacRae
JCJ.G. Chase
J.G. Chase
GRG.W. Rodgers
G.W. Rodgers
GCG. Charles Clifton
G. Charles Clifton