Davide Gamba

Davide Gamba

Auto-generated profile, based on publicly available information

Davide Gamba

CERN Meyrin Switzerland

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025
Verified
Conference Paper
Open access
PDF file
GBGonçalo Baptista
Gonçalo Baptista
SRShikha Rathi
Shikha Rathi
MRMichael Roosa
Michael Roosa
QSQuentin Senetaire
Quentin Senetaire
JSJonas Sommerfeldt
Jonas Sommerfeldt
NPNancy Paul
Nancy Paul
PAX (antiProtonic Atom X-ray spectroscopy) is a new experiment with the aim to test strong-field quantum electrodynamics (QED) effects by performing high-precision x-ray spectroscopy of antiprotonic atoms. By utilizing advanced microcalorimeter detection techniques and a low-energy antiproton beam provided by the ELENA ring at CERN, gaseous targets will be used for the creation of antiprotonic atoms, and the measurement of transitions between circular Rydberg states will be conducted with up to two orders of magnitude improved accuracy over previous studies using high-purity germanium detectors. %\cite{Gotta2008, Ullom2015} Our approach eliminates the longstanding issue of nuclear uncertainties that have hindered prior studies using highly charged ions, thus enabling direct and purely QED-focused measurements. %\cite{Paul2021} By precisely probing atomic systems with electric fields up to two orders of magnitude above the Schwinger limit, PAX will test vacuum polarization and second-order QED corrections, opening new frontiers in fundamental physics and uncovering potential pathways to physics beyond the Standard Model.

28 June 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MSM. Schaumann
M. Schaumann
DGD. Gamba
D. Gamba
HMH. Garcia Morales
H. Garcia Morales
RCR. Corsini
R. Corsini
MGM. Guinchard
M. Guinchard
JWJ. Wenninger
J. Wenninger

2 January 2020 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
JVJaime Maria Coello De Portugal - Martinez Vazquez
Jaime Maria Coello De Portugal - Martinez Vazquez
RTR. Tomás
R. Tomás
LFL. Fiscarelli
L. Fiscarelli
DGD. Gamba
D. Gamba
MMM. Martino
M. Martino
Type-II superconductors, like the Nb3Sn used in the new HL–LHC quadrupole triplet and 11 T dipoles or FCC dipoles, are known to show an unstable behavior during magnetic-field ramps. This paper presents an analysis of the possible effects on the beam dynamics of this behavior of the magnets, with a focus on emittance blow-up.

9 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
SYS. Yammine
S. Yammine
MBMarta Bajkó
Marta Bajkó
ABA. Ballarino
A. Ballarino
MBM. J. Bednarek
M. J. Bednarek
DBD. Bozzini
D. Bozzini
MZM. Zerlauth
M. Zerlauth
This contribution describes the experimental program already undergoing and to be completed on the High Luminosity Large Hadron Collider (HL-LHC) Inner Triplet (IT) String, an important intermediate milestone of the HL-LHC project at CERN. First, it describes the magnet circuits of the HL-LHC IT String. Afterwards, the different systems installed to perform the experimental program are detailed. The proposed tests are defined for the validation of the cryogenic system, the full remote alignment system, the powering system, and the protection schemes of all magnets working in unison. This strategy will allow for a verification of the integrated powering system before the final installation and commissioning in the HL-LHC's underground areas.

1 March 2021 in Physics Letters A
Verified
Journal Article
Closed access
ACAlessandro Curcio
Alessandro Curcio
MBM. Bergamaschi
M. Bergamaschi
RCR. Corsini
R. Corsini
DGD. Gamba
D. Gamba
WFW. Farabolini
W. Farabolini
APA. Potylitsyn
A. Potylitsyn

9 March 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
KMKelsey Morgan
Kelsey Morgan
TAToshiyuki Azuma
Toshiyuki Azuma
GBGonc¸alo Baptista
Gonc¸alo Baptista
DBDaniel Becker
Daniel Becker
DBDouglas Bennett
Douglas Bennett
DSDaniel Swetz
Daniel Swetz
PAX (antiProtonic Atom X-ray spectroscopy) is an experiment that aims to test strong-field quantum elec trodynamics (QED) effects by performing high-precision X ray spectroscopy of antiprotonic atoms. PAX will use a low energy antiproton beam provided by the Extra Low Energy Antiproton (ELENA) ring at the European Organization for Nuclear Research (CERN) to create antiprotonic atoms. A superconducting transition-edge sensor (TES) spectrometer will be used to measure the energy of transitions between circular Rydberg states in these atoms. The energy range of interest for the experiment spans 50 keV to 250 keV, and the desired precision for measuring the centroids of the emission lines is 10−5. The spectrometer for PAX is intended to have four 96-pixel TES arrays and will be read out with a microwave superconducting quantum interference device (SQUID) multiplexer. As a step towards building the full instrument, we built a scaled-down version of the spectrometer that was installed at the TEst Line for Machine And Antimatter eXperiments (TELMAX) facility at ELENA in April 2025. The purpose of this deployment was to make an observation of X-ray emission by antiprotonic atoms and to better understand the effect of the pionic charged particle background due to antiproton annihilation on the per formance of the TES array. This pilot spectrometer had an array of 60 TES pixels in a compact adiabatic demagnetization refrigerator (ADR) cryostat. The sensors were read out with a microwave SQUID multiplexer. Each pixel consisted of a molybdenum/gold bilayer TES with a co-planar gold “landing pad” for a bulk tin absorber that was attached by an epoxy joint. We discuss the design of the TES pixels, the microwave SQUID readout, and the cryogenic platform. Finally, we present calibration data obtained at TELMAX using radioactive sources to assess the performance of the spectrometer in the antiproton beam-off condition.