21 August 2023 in IEEE Transactions on Biomedical Engineering
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump
11 April 2025 in IEEE Transactions on Biomedical Engineering
Objective: Operating conditions significantly influence hemolysis generation in rotodynamic blood pumps (RBPs). Previous experiments conducted under constant operating conditions have demonstrated that lower flow rates are associated with a higher normalized index of hemolysis (NIH). However, in clinical scenarios, the pump flow rate fluctuates in response to the residual cardiac function. This study aims to investigate the effects of various pulsatile operating conditions on hemolysis generation and von Willebrand Factor (vWF) degradation of RBP. Methods: To investigate these conditions, pulsatile flow experiments were conducted for 12 hours using HeartMate 3 (HM3, Abbott Inc, USA) in a hybrid mock circulatory loop with citrated human blood from hemochromatosis patients. Three operating conditions (high, low, and no residual cardiac function) were examined under two pump speed settings: normal (5400 rpm, 4.3 L/min) and low (4800 rpm, 2.5 L/min). Hemolysis was assessed by measuring delta free hemoglobin every 30 minutes (dfHb30 min) and calculating NIH. High molecular weight (HMW) vWF multimer degradation was assessed using immunoblotting. Results: There was no significant difference in dfHb30 min (p>0.388), NIH (p > 0.382), and HMW vWF multimers degradation (p > 0.364) between the three operating conditions, but differences in these parameters were observed between the normal and low speed settings. Meanwhile, a consistent trend in the hemolysis outcomes was observed with slightly elevated hemolysis in no and high pulsatility conditions of both speed settings. Conclusion: Hemocompatibility of the HM3 is not significantly affected by periodic high/low flow or backflows through the pump in in-vitro evaluation but rather by the pump operating condition: flow rate and pump speed.
21 March 2025 in IEEE Transactions on Biomedical Engineering
Objective: Implantable ventricular assist devices to support pediatric patients with left ventricular failure remain an unmet medical need. The aim of this work was to assess the feasibility of a miniaturized two-stage pump concept as a left ventricular assist device (LVAD) intended for small pediatric patients. Methods: The pump leverages a two-stage design with a back-to-back impeller configuration. Computational fluid dynamics (CFD) alongside finite element method (FEM) analysis were utilized to design the pump and its actuation. The magnetic and hydrodynamic properties of the axial and radial bearing were designed and analyzed considering the motor characteristics. The hydraulic performance was validated in a flow loop, and hemocompatibility parameters were numerically assessed and compared to the HeartMate 3. Results: At design condition of 1.5 L/min and 6400 rpm, the Two-Stage Pump builds up a pressure of 58 mmHg. The dynamic analysis of the radial hydrodynamic journal bearing demonstrated that an impeller equilibrium position can be achieved by introducing an additional radial load to balance the forces. The axial reluctance force of the motor is shown to be sufficient to balance the axial forces. The motor losses of 0.18 W result in a local temperature increase of 0.4 K. Compared to the HeartMate 3, the Two-Stage Pump demonstrates similar or even superior hemocompatibility results for pediatric use at a reduced circumferential velocity of 3.7 m/s. Conclusion and significance: The concept of the Two-Stage Pump demonstrates feasibility and presents compelling results to address the medical challenge of an implantable LVAD for pediatric patients.
8 April 2024 in IEEE Open Journal of the Industrial Electronics Society
A novel implantable total artificial heart, hereinafter referred to as the ShuttlePump , is currently under development in a research collaboration between the Medical University of Vienna, the Power Electronic Systems Laboratory of ETH Zurich and Charite Berlin. Its novel, low-complexity, pulsatile pumping principle requires a specially shaped piston performing a controlled, synchronized linear-rotary motion while providing the necessary hydraulic force and torque. The machine design of the Permanent Magnet Synchronous Machine (PMSM)-based linear-rotary actuator was conducted in previous work of the authors, leading to the construction of a hardware prototype satisfying the application requirements in terms of electromechanical force, torque, power losses, and volume. This article provides the details of the closed-loop linear-rotary position control system required to operate the ShuttlePump . The design of the position control system targets tight reference tracking ( $\pm$ 8 mm linear stroke and continuous rotation) up to an operational frequency of 5 Hz, under the heavy disturbance introduced by the axial hydraulic load force, as high as 45 N. The experimental measurements show successful linear-rotary position tracking under the specified axial load, with a maximum error of 1 mm and 5 $^{\circ }$ .
16 August 2023 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
The shuttle pump is a novel implantable total artificial heart (TAH) concept based on a Linear-Rotary Actuator (LiRA) and currently under development at the Power Electronic Systems Laboratory, ETH Zurich in close partnership with Charité Berlin and the Medical University of Vienna. This paper presents the analysis, design and realization of the ShuttlePump Linear Actuator (LA) part, which is necessary to provide about 45 N of axial actuation force. Design criteria are minimization of volume and generated power losses in the winding, which could result in excess heating and/or blood damage, i.e. protein denaturation and aggregation. The LA is implemented as a Tubular LA (TLA) to maximize the active area for linear/axial force generation. After a preliminary analysis based on first principles, the TLA is optimized in detail with the aid of FEM simulations. The experimental measurements conducted on the realized TLA prototype verify the FEM simulation results and confirm the suitability for the realization of the ShuttlePump TAH.
6 December 2023 in IEEE Open Journal of the Industrial Electronics Society
In the context of a collaboration between the Medical University of Vienna , the Power Electronic Systems Laboratory of ETH Zurich , and Charité Berlin , the novel implantable total artificial heart (TAH) ShuttlePump is currently being developed. Its novel, low-complexity pumping concept requires a compact Linear-Rotary Actuator (LiRA). The Linear Actuator (LA) part was designed, realized, and experimentally verified in previous work, and it can provide a peak axial force of about 45 N with about 8 W of continuous power dissipation. This paper presents the details of the Rotary Actuator (RA) part. This has considerably lower output power requirements (about 100 mW) due to the low operating torque and angular speed (3.1 mNm and up to 300 rpm, respectively). However, the RA is highly constrained spatially, as it needs to be integrated very close to the previously realized LA. This forces a permanent magnet synchronous machine (PMSM) design with a rotor only partially equipped with PMs and stators covering only half of the total circumference, which introduces a considerable cogging component to the total torque. The proposed PMSM is hence optimized using Finite Element Methods (FEM) simulations to select a final design with low power losses and low cogging-induced angular speed ripple. The machine is realized as a hardware prototype, and the experimental measurements confirm that the proposed RA can meet the continuous torque requirement with 324 mW of power losses. The successful implementation of the RA (and LA) finally verifies the practical feasibility of the integrated LiRA and provides the basis for a comprehensive test of the complete ShuttlePump in a hydraulic test rig in the course of further research.