Tim Rese

Tim Rese

Auto-generated profile, based on publicly available information

Tim Rese

Institute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany; Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt - Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
TBTim Bierewirtz
Tim Bierewirtz
KNKrishnaraj Narayanaswamy
Krishnaraj Narayanaswamy
RGRosario Giuffrida
Rosario Giuffrida
TRTim Rese
Tim Rese
DBDominik Bortis
Dominik Bortis
Marcus GraneggerMarcus Granegger
Marcus Granegger
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump

27 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ISIsabell Schulz
Isabell Schulz
FHFelix Hehnen
Felix Hehnen
KLKevin Harry Lausch
Kevin Harry Lausch
SGSophia Mareike Geisler
Sophia Mareike Geisler
ÜHÜmit Hasirci
Ümit Hasirci
UKUlrich Kertzscher
Ulrich Kertzscher
The COVID-19 pandemic has focused attention on the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the naturally ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in variously sized and shaped indoor environments, with or without an audience.

20 June 2023 in medRxiv
Verified
Preprint
Open access
PDF file
ISIsabell Schulz
Isabell Schulz
FHFelix Hehnen
Felix Hehnen
KLKevin Harry Lausch
Kevin Harry Lausch
SGSophia Mareike Geisler
Sophia Mareike Geisler
UHUemit Hasirci
Uemit Hasirci
UKUlrich Kertzscher
Ulrich Kertzscher
The COVID-19 pandemic has focused attention to the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the natural ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in various sized and shaped indoor environments, with or without an audience.

11 December 2024
Verified
Conference Paper
Closed access
ISIsabell Schulz
Isabell Schulz
TBTim Bierewirtz
Tim Bierewirtz
VFVera Froese
Vera Froese
TRTim Rese
Tim Rese
MLMichael Lommel
Michael Lommel
UKUlrich Kertzscher
Ulrich Kertzscher
This paper presents the design and functional evaluation of a novel pulsatile mock-loop system designed to accommodate whole natural heart samples of various sizes, replicating both systemic and pulmonary circulation. Unlike existing models in the literature, this mock-loop uses an external pressurisation principle that preserves the integrity of native atrial and ventricular tissue, eliminating the need for penetration or damage during the experimental process. The flow and pressure profiles indicate a moderate functionality of the heart. Comparative analysis with other mock-loop designs highlights the advantages of this approach in maintaining tissue viability and providing a more realistic simulation of the natural environment of the heart.

2 November 2025 in Journal of Dentistry
Verified
Journal Article
Open access
TRTim Rese
Tim Rese
FMFlorentina Sophie Melzow
Florentina Sophie Melzow
ISIsabell Schulz
Isabell Schulz
MLMichael Lommel
Michael Lommel
KMKira Sophia Martinus
Kira Sophia Martinus
SPSebastian Paris
Sebastian Paris
Aerosol-generating treatments in dental practice carry the risk of releasing potentially infectious body fluids (PIBF), resulting in possible disease transmission from one patient to others and to the dental staff. The SARS-CoV-2 pandemic has revealed the urgent need to provide precise and comprehensible safety measures for all kinds of diseases. Dentists and dental staff are more exposed to potentially infectious aerosols than the general population. However, there is no established method to quantify the infectivity of aerosols and splatter as encountered by dentists. This study presents a proof-of-principle setup to differentiate PIBF and drill coolant within dental aerosols and splatter. In the presented model a saliva substitute with a saline tracer dripped into the artificial oral cavity of a dental phantom head. A water-cooled contra-angle handpiece was used to generate aerosol and splatter during a standard dental procedure. Throughout the process, the aerosol enriched air in front of the artificial cavity was absorbed and analysed by measurement devices. Larger droplets were collected by a splatter plate in front of the oral cavity for quantification. The study showed that saliva in the dental aerosol had a release rate of 19.6 μg/min and in splatter 444.8μg/min. Due to the measuring accuracy of 2.4nL for aerosol and 7.7nL for splatter, even small amounts of saliva substitute fluid can be detected. The experimental setup presented and tested here is suitable for detecting and quantifying the various components of dental aerosols and splatter. The setup is highly sensitive, enables the collection of reproducible data, and exhibits a good SNR across all boundary conditions. The ability to quantify these fractions allows realistic risk assessment of airborne- and contact infections in dentistry and supports the development of effective protective strategies for dental staff and patients.