21 August 2023 in IEEE Transactions on Biomedical Engineering
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump
2 November 2025 in Journal of Dentistry
Aerosol-generating treatments in dental practice carry the risk of releasing potentially infectious body fluids (PIBF), resulting in possible disease transmission from one patient to others and to the dental staff. The SARS-CoV-2 pandemic has revealed the urgent need to provide precise and comprehensible safety measures for all kinds of diseases. Dentists and dental staff are more exposed to potentially infectious aerosols than the general population. However, there is no established method to quantify the infectivity of aerosols and splatter as encountered by dentists. This study presents a proof-of-principle setup to differentiate PIBF and drill coolant within dental aerosols and splatter. In the presented model a saliva substitute with a saline tracer dripped into the artificial oral cavity of a dental phantom head. A water-cooled contra-angle handpiece was used to generate aerosol and splatter during a standard dental procedure. Throughout the process, the aerosol enriched air in front of the artificial cavity was absorbed and analysed by measurement devices. Larger droplets were collected by a splatter plate in front of the oral cavity for quantification. The study showed that saliva in the dental aerosol had a release rate of 19.6 μg/min and in splatter 444.8μg/min. Due to the measuring accuracy of 2.4nL for aerosol and 7.7nL for splatter, even small amounts of saliva substitute fluid can be detected. The experimental setup presented and tested here is suitable for detecting and quantifying the various components of dental aerosols and splatter. The setup is highly sensitive, enables the collection of reproducible data, and exhibits a good SNR across all boundary conditions. The ability to quantify these fractions allows realistic risk assessment of airborne- and contact infections in dentistry and supports the development of effective protective strategies for dental staff and patients.