James Bland

James Bland

Auto-generated profile, based on publicly available information

James Bland

Tokamak Energy Ltd, 173 Brook Drive, Milton Park, Abingdon, OX14 4SA, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2017 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJames Bland
James Bland
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CMColm J. McGinnity
Colm J. McGinnity
ARAndrew J. Reader
Andrew J. Reader
Positron emission tomography (PET) image reconstruction is highly susceptible to the impact of Poisson noise, and if shorter acquisition times or reduced injected doses are used, the noisy PET data become even more limiting. The recent development of kernel expectation maximization is a simple way to reduce noise in PET images, and we show in this paper that impressive dose reduction can be achieved when the kernel method is used with MR-derived kernels. The kernel method is shown to surpass maximum likelihood expectation maximization (MLEM) for the reconstruction of low-count datasets (corresponding to those obtained at reduced injected doses) producing visibly clearer reconstructions for unsmoothed and smoothed images, at all count levels. The kernel EM reconstruction of 10% of the data had comparable whole brain voxel-level error measures to the MLEM reconstruction of 100% of the data (for simulated data, at 100 iterations). For regional metrics, the kernel method at reduced dose levels attained a reduced coefficient of variation and more accurate mean values compared to MLEM. However, the advances provided by the kernel method are at the expense of possible over-smoothing of features unique to the PET data. Further assessment on clinical data is required to determine the level of dose reduction that can be routinely achieved using the kernel method, whilst maintaining the diagnostic utility of the scan.

17 March 2023 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
SMSteven McNamara
Steven McNamara
OAOtto Asunta
Otto Asunta
JBJames Robert Bland
James Robert Bland
PBPeter Francis Buxton
Peter Francis Buxton
CCCary Colgan
Cary Colgan
Oleksandr MarchukOleksandr Marchuk
Oleksandr Marchuk
Ion temperatures of over 100 million degrees Kelvin (8.6 keV) have been produced in the ST40 compact high-field spherical tokamak (ST). Ion temperatures in excess of 5 keV have not previously been reached in any ST and have only been obtained in much larger devices with substantially more plasma heating power. The corresponding fusion triple product is calculated to be n i 0 T i 0 τ E ≈ 6 ± 2 × 10 18 m − 3 keVs . These results demonstrate for the first time that ion temperatures relevant for commercial magnetic confinement fusion can be obtained in a compact high-field ST and bode well for fusion power plants based on the high-field ST.

29 August 2024 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
SMSteven McNamara
Steven McNamara
AAAleksandra Alieva
Aleksandra Alieva
MTM.S. Anastopoulos Tzanis
M.S. Anastopoulos Tzanis
OAOtto Vihtori Asunta
Otto Vihtori Asunta
JBJames Robert Bland
James Robert Bland
Oleksandr MarchukOleksandr Marchuk
Oleksandr Marchuk
ST40 is a compact, high-field ( B T 0 ⩽ 2.1 T ) spherical tokamak (ST) with a mission to expand the physics and technology basis for the ST route to commercial fusion. The ST40 research programme covers confinement and stability; solenoid-free start-up; high-performance operating scenarios; and plasma exhaust. In 2022, ST40 obtained central deuterium ion temperatures of 9.6 ± 0.4   keV , demonstrating for the first time that pilot plant relevant ion temperatures can be reached in a compact, high-field ST. Analysis of these high-ion temperature plasmas is presented, including a summary of confinement, transport and microstability characteristics, and energetic particle instabilities. Recent scenario development activities have focused on establishing diverted H-mode plasmas across a range of toroidal fields and plasma currents, along with scenarios with high non-inductive current fractions. In future operations, beginning in 2025, a 1 MW dual frequency (104/137 GHz) electron cyclotron (EC) system will be installed to enable the study of EC and electron Bernstein wave plasma start-up and current drive. Predictive modelling of the potential performance of these systems is presented.

8 September 2019 in Medical Physics
Verified
Journal Article
Open access
PDF file
JBJames Bland
James Bland
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CCCasper da Costa‐Luis
Casper da Costa‐Luis
ARAndrew J. Reader
Andrew J. Reader
Purpose: Numerous image reconstruction methodologies for positron emission tomography (PET) have been developed that incorporate magnetic resonance (MR) imaging structural information, producing reconstructed images with improved suppression of noise and reduced partial volume effects. However, the influence of MR structural information also increases the possibility of suppression or bias of structures present only in the PET data (PET‐unique regions). To address this, further developments for MR‐informed methods have been proposed, for example, through inclusion of the current reconstructed PET image, alongside the MR image, in the iterative reconstruction process. In this present work, a number of kernel and maximuma posteriori(MAP) methodologies are compared, with the aim of identifying methods that enable a favorable trade‐off between the suppression of noise and the retention of unique features present in the PET data.Methods: The reconstruction methods investigated were: the MR‐informed conventional and spatially compact kernel methods, referred to as KEM and KEM largest value sparsification (LVS) respectively; the MR‐informed Bowsher and Gaussian MR‐guided MAP methods; and the PET‐MR‐informed hybrid kernel and anato‐functional MAP methods. The trade‐off between improving the reconstruction of the whole brain region and the PET‐unique regions was investigated for all methods in comparison with postsmoothed maximum likelihood expectation maximization (MLEM), evaluated in terms of structural similarity index (SSIM), normalized root mean square error (NRMSE), bias, and standard deviation. Both simulated BrainWeb (10 noise realizations) and real [18F] fluorodeoxyglucose (FDG) three‐dimensional datasets were used. The real [18F]FDG dataset was augmented with simulated tumors to allow comparison of the reconstruction methodologies for the case of known regions of PET‐MR discrepancy and evaluated at full counts (100%) and at a reduced (10%) count level.Results: For the high‐count simulated and real data studies, the anato‐functional MAP method performed better than the other methods under investigation (MR‐informed, PET‐MR‐informed and postsmoothed MLEM), in terms of achieving the best trade‐off for the reconstruction of the whole brain and PET‐unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation. The inclusion of PET information in the anato‐functional MAP method enables the reconstruction of PET‐unique regions to attain similarly low levels of bias as unsmoothed MLEM, while moderately improving the whole brain image quality for low levels of regularization. However, for low count simulated datasets the anato‐functional MAP method performs poorly, due to the inclusion of noisy PET information in the regularization term. For the low counts simulated dataset, KEM LVS and to a lesser extent, HKEM performed better than the other methods under investigation in terms of achieving the best trade‐off for the reconstruction of the whole brain and PET‐unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation.Conclusion: For the reconstruction of noisy data, multiple MR‐informed methods produce favorable whole brain vs PET‐unique region trade‐off in terms of the image quality metrics of SSIM and NRMSE, comfortably outperforming the whole image denoising of postsmoothed MLEM.

6 June 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJames Bland
James Bland
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CMColm J. McGinnity
Colm J. McGinnity
AHAlexander Hammers
Alexander Hammers
ARAndrew J. Reader
Andrew J. Reader
Positron emission tomography (PET) is a highly sensitive functional and molecular imaging modality which can measure picomolar concentrations of an injected radionuclide. However, the physical sensitivity of PET is limited, and reducing the injected dose leads to low count data and noisy reconstructed images. A highly effective way of reducing noise is to reparameterize the reconstruction in terms of MR-derived spatial basis functions. Spatial basis functions derived using the kernel method have demonstrated excellent noise reduction properties and maintain shared PET-MR detailed structures. However, as previously shown in the literature, the MR-guided kernel method may lead to excessive smoothing of structures that are only present in the PET data. This paper makes two main contributions in order to address this problem: first, we exploit the potential of the MR-guided kernel method to form more spatially compact basis functions which are able to preserve PET-unique structures, and second, we consider reconstruction at the native MR resolution. The former contribution notably improves the recovery of structures which are unique to the PET data. These adaptations of the kernel method were compared to the conventional implementation of the MR-guided kernel method and also to maximum likelihood expectation maximization, in terms of ability to recover PET unique structures for both simulated and real data. The spatially compact kernel method showed clear visual and quantitative improvements in the reconstruction of the PET unique structures, relative to the conventional kernel method for all sizes of PET unique structures investigated, whilst maintaining to a large extent the impressive noise mitigating and detail preserving properties of the conventional MR-guided kernel method. We therefore conclude that a spatially compact parameterization of the MR-guided kernel method, should be the preferred implementation strategy in order to obviate unnecessary losses in PET-unique details.

14 December 2022 in Nuclear Fusion
Verified
Journal Article
Open access
JBJ. Bland
J. Bland
JVJ. Varje
J. Varje
NGN.N. Gorelenkov
N.N. Gorelenkov
MGM.P. Gryaznevich
M.P. Gryaznevich
SSS.E. Sharapov
S.E. Sharapov
TSTeam The ST40
Team The ST40
Experiments on the high field spherical tokamak ST40 have led to the recent observation of interplay between beam-driven modes of sweeping frequency (chirping modes) and transitions to the enhanced global confinement regime (H-mode) and back to the low confinement regime (L-mode). The H-modes of plasma confinement are identified from decreased intensity of Dα signal and from clear distinctions in the edge gradients of the visible plasma boundary (observed as a sharp plasma edge in camera images). The beam-driven chirping modes, identified as ideal magnetohydrodynamics beta-induced Alfvén acoustic eigenmodes modes, are observed in Mirnov coil signals, interferometry, and soft x-ray diagnostics. A moderate amplitude ‘primer’ chirping mode usually precedes an H–L transition. This is followed by a ‘dominant’ chirping mode with higher amplitude during the L-mode. The L–H transition back to the improved confinement occurs on a longer time scale of tens of ms, consistent with the slowing down time scale of fast beam ions. A dramatic decrease in toroidal plasma rotation is systematically observed associated with chirping modes sweeping down to zero frequency. Resonance maps built for the beam-driven chirping modes with the ASCOT (accelerated simulation of charged particle orbits in torodoial devices) code show that the resonant beam ions have orbits near the trapped-passing boundary. The ASCOT modelling assesses how losses of the resonant fast ions caused by the chirping modes with high enough amplitude modify the torque, potentially affecting the plasma rotation.