Wenpeng Li

Wenpeng Li

Auto-generated profile, based on publicly available information

Wenpeng Li

State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
LCLiang Cao
Liang Cao
LZLisheng Zhong
Lisheng Zhong
YLYinge Li
Yinge Li
WLWenpeng Li
Wenpeng Li
Jinghui GaoJinghui Gao
Jinghui Gao
GCGeorge Chen
George Chen
Low direct-current (DC) conductivity is one of the most desired characteristics for crosslinked polyethylene (XLPE) as a high-voltage DC cable insulation material. In this Letter, a correlation between the DC conductivity and cross-linking characteristics of XLPE-polystyrene (PS) composites at 50 °C was studied. Experimental results show that by adjusting the cross-linking structure, different trap distribution characteristics for XLPE-PS composites were realized. With the increase in the cross-linking agent content, DC conductivities of XLPE-PS composites tend to decrease, and the introduced average trap depth increases correspondingly. An increase of 0.07 eV for average charge trap depth in XLPE-PS composites could be acquired in the test range. It is considered that the increase in the average trap depth reduces the carrier mobility, contributing to the reduction of DC conductivity for XLPE-PS composites. Thus, the DC conductivity and average trap depth of XLPE composites show a strong relevance. The results suggest that the interaction between PS particles and the matrix introduced by cross-linking plays a dominant role in determining the charge conduction for XLPE-PS composites.

11 August 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
XSXin Shen
Xin Shen
JWJiandong Wu
Jiandong Wu
WLWeikang Li
Weikang Li
WLWenpeng Li
Wenpeng Li
YYYi Yin
Yi Yin
The threshold electric field and temperature sensitivity associated with charge transport in an LDPE/SiO 2 nanocomposite were investigated based on space charge and conductivity characteristics. The electric field ranged from 1 kV/mm to 200 kV/mm, and the temperature was from 30 °C to 70 °C. A three-stage variation trend for space charge accumulation and conductance was observed with the rising of the electric field. Correspondingly, the threshold fields increased and decreased with the increase in filling concentration and temperature, respectively. The temperature self-sensitivity coefficient of space charge and conductance showed a single-peak trend, and the peak position was related to the maximum and minimum of the threshold electric field, respectively. The maximum temperature self-sensitivity coefficient of conductance and space charge increased after filling the nanoparticles, whereas the relative temperature sensitivity of conductance decreased considerably. The two threshold electric fields of space charge were lower than those of conductance, and the field difference between them increased with the increase in filling concentration and temperature. This phenomenon may be related to the modulation of various carrier transport processes by traps introduced by nano-filling.

30 December 2024 in High Voltage
Verified
Journal Article
Open access
Muneeb AhmedMuneeb Ahmed
Muneeb Ahmed
LZLisheng Zhong
Lisheng Zhong
Jinghui GaoJinghui Gao
Jinghui Gao
FLFei Li
Fei Li
NXNuo Xu
Nuo Xu
LCLiang Cao
Liang Cao
Developing a stable insulation material stands as a crucial challenge for high‐voltage direct current (HVDC) cable insulation. This work proposes an alloying strategy to significantly enhance the breakdown strength and high‐temperature resistivity of cross‐linked polyethylene (XLPE). The strategy involves blending low‐density polyethylene (LDPE) with polystyrene (PS), resulting in a polymeric alloy. Confirmation of PS alloying within XLPE is supported by observed shifts in polyethylene miller indices (110) and (200) planes. The dicumyl peroxide used as a crosslinking agent demonstrates an ideal 1.41% enhancement in LDPE‐PS crosslinking. The integration of aromatic ethers in the cross‐linked network enhances temperature stability. Alloying PS at 220°C in XLPE leads to improved inter‐molecular interactions and increased interfacial area, creating a sea–island morphology that resolves voids and limits defect or crack propagation by forming additional trapping sites. The enhanced breakdown strength and reduced conductivity of XLPE‐PS are attributed to increased deep trapping sites and reduced carrier mobility resulting from alloying. The reduced conductivity at 70°C and 90°C demonstrates stability under electric fields. Remarkable breakdown strength improvements of 27.5% and 23.6% are observed at 30°C and 50°C. The proposed alloying strategy suggests replacing XLPE with advanced XLPE‐PS, offering promising prospects for HVDC insulation.

30 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
WLWenpeng Li
Wenpeng Li
KLKanghong Liu
Kanghong Liu
FLFei Li
Fei Li
Jinghui GaoJinghui Gao
Jinghui Gao
XLXinsheng Lu
Xinsheng Lu
LZLisheng Zhong
Lisheng Zhong
The cross-linking byproducts affecting the conductivity of cross-linked polyethylene (XLPE) determine the electric field distribution and temperature stability of cable insulation, and thus the detection of residual cross-linking byproducts plays an important role on the reliability of High Voltage Direct Current (HVDC) cable system. This paper employs the time-dependent polarization current measurement to investigate the dielectric relaxation in XLPE with different contents of cross-linking byproduct at extra-low frequency (ELF). The results show that two Debye-type dielectric relaxations appear at the frequency range of 10 -4 ~10 -3 Hz (defined as α relaxation) and 10 -3 ~10 -2 Hz (defined as β relaxation) respectively, in which the associated static permittivity and the peak losses are proportional to the byproduct contents for the specimens with different degassing time. Further pulsed electro-acoustic measurement (PEA) shows that β relaxation time coincides with time length for accumulation of hetero-charge near electrodes caused by the ionization of byproducts. And the time-dependency of weight loss for the specimen suggests α relaxation might be responsible for the dissipation of cross-linking byproduct during degassing. Our work may shed light on a promising non-destructive approach to detecting the level of residual cross-linking byproducts through dielectric relaxation measurement at extra-low frequency.

16 December 2025 in High Voltage
Verified
Journal Article
Open access
WLWenpeng Li
Wenpeng Li
SBShuxin Bi
Shuxin Bi
CZChong Zhang
Chong Zhang
ZGZhiyi Gao
Zhiyi Gao
YZYang Zhou
Yang Zhou
LZLisheng Zhong
Lisheng Zhong
Cross‐linking byproducts in the cross‐linked polyethylene (XLPE) cable insulation material significantly affect the insulation properties of XLPE, and the non‐destructive detection method for cross‐linking byproducts during cable degassing process still faces great challenges. This work develops an extra‐low frequency (ELF) dielectric analysis method based on time‐dependent polarisation current for non‐destructive detection of byproducts in XLPE. The effects of single byproduct of acetophenone and cumyl alcohol on the ELF dielectric properties of XLPE are studied separately. The ELF associated static permittivity and the dielectric loss of XLPE rise as the content of the single byproduct increases, and the α relaxation (10 −4 –10 −3 Hz) and β relaxation (10 −3 –10 −2 Hz) of XLPE are observed. Ionisation of acetophenone occurs above electric field strength of 20 kV, whereas ionisation tends to saturate above 50 kV. The optimal field strength for ELF dielectric testing of XLPE is determined to be 20–50 kV. Furthermore, the degassing factor is proposed to accurately determine the removal of byproducts. Based on these, the non‐destructive detection of degassing of XLPE cable is achieved. The proposed ELF dielectric analysis method enables the non‐destructive detection of byproducts in cables, opening a new avenue for cable degassing effect evaluation.