Although the impact of therapeutic thoracentesis on lung function and blood gases has been evaluated in several studies, some physiological aspects of pleural fluid withdrawal remain unknown. The aim of the study was to assess the changes in pleural pressure amplitude (Pplampl) during the respiratory cycle and respiratory rate (RR) in patients undergoing pleural fluid withdrawal. The study included 23 patients with symptomatic pleural effusion. Baseline pleural pressure curves were registered with a digital electronic manometer. Then, the registrations were repeated after the withdrawal of consecutive portions of pleural fluid (200 ml up to 1000 ml and 100 ml above 1000 ml). In all patients the pleural pressure curves were analyzed in five points, at 0, 25%, 50%, 75% and 100% of the relative volume of pleural effusion withdrawn in particular patients. There were 11 and 12 patients with right sided and left sided pleural effusion, respectively (14 M, 9F, median age 68, range 46–85 years). The most common cause of pleural effusion were malignancies (20 pts., 87%). The median total volume of withdrawn pleural fluid was 1800 (IQR 1500–2400) ml. After termination of pleural fluid withdrawal Pplampl increased in 22/23 patients compared to baseline. The median Pplampl increased from 3.4 (2.4–5.9) cmH2O to 10.7 (8.1–15.6) cmH2O (p < 0.0001). Three patterns of Pplampl changes were identified. Although the patterns of RR changes were more diversified, a significant increase between RR at baseline and the last measurement point was found (p = 0.0097). In conclusion, therapeutic thoracentesis is associated with significant changes in Pplampl during the respiratory cycle. In the vast majority of patients Pplampl increased steadily during pleural fluid withdrawal. There was also an increase in RR. The significance of these changes should be elucidated in further studies. ClinicalTrial.gov, registration number: NCT02192138 , registration date: July 1st, 2014.
Independent lung ventilation (ILV) is a life-saving procedure in unilateral pulmonary pathologies. ILV is underused in clinical practice, mostly due to the technically demanding placement of a double lumen endotracheal tube (ETT). Moreover, the determination of ventilation parameters for each lung in vivo is limited. In recent years, the development of 3D printing techniques enabled the production of highly accurate physical models of anatomical structures used for in vitro research, considering the high risk of in vivo studies. The purpose of this study was to assess the influence of double-lumen ETT on the gas transport and mixing in the anatomically accurate 3D-printed model of the bronchial tree, with lung lobes of different compliances, using various ventilation modes. The bronchial tree was obtained from Respiratory Drug Delivery (RDD Online, Richmond, VA, USA), processed and printed by a dual extruder FFF 3D printer. The test system was also composed of left side double-lumen endotracheal tube, Siemens Test Lung 190 and anesthetic breathing bag (as lobes). Pressure and flow measurements were taken at the outlets of the secondary bronchus. The measured resistance increased six times in the presence of double-lumen ETT. Differences between the flow distribution to the less and more compliant lobe were more significant for the airways with double-lumen ETT. The ability to predict the actual flow distribution in model airways is necessary to conduct effective ILV in clinical conditions.
1 April 2022 in Journal of Aerosol Medicine and Pulmonary Drug Delivery
Background: The severity of airway obstruction may affect patient's ability to perform an effective drug inhalation from a dry powder inhaler (DPI). Also, an incorrect inhalation technique may negatively affect the efficacy of asthma treatment. The aims of the study were (1) to analyze and compare inhalation profiles recorded with the use of different inhalation techniques, and thus, (2) to establish model inhalation profiles representative for healthy subjects and subjects with mild and moderate-to-severe asthma. Methods: This study was performed in healthy volunteers, patients with mild and moderate-to-severe asthma. A modified flow-volume test to define two different expiratory levels (to residual volume and half-way to residual volume) was performed. Inspiratory flow parameters were extracted: peak inspiratory flow rate (PIFinh), time at which peak inspiratory flow rate occurs (tPIFinh), total inhalation time (T), and inhaled volume (V). Test of frequency for tPIFinh100% and tPIFinh50% by asthma severity was performed, to provide information about initial flow accelerations. The impact of two different expiratory levels preceding inhalation (with severity of asthma as a categorical factor) on inspiratory flow parameters was examined. Results: PIFinh was dependent upon asthma severity (p = 0.046). Type of exhalation before inhalation had no effect on PIFinh values. V value was significantly affected both by asthma severity (p = 0.024) and type of exhalation before inhalation (p < 0.0001). Mean T value was influenced by type of exhalation before inhalation (p = 0.0003), but not by asthma severity. Mean tPIFinh value was affected by the type of exhalation before inhalation only in healthy subjects (p = 0.01). Conclusions: Both asthma severity and type of exhalation before inhalation have little impact on the dynamics of inhalation through a DPI. An alternative form of equation describing inhalation profiles demonstrating a relationship between lung mechanics and dynamics of inspiratory profile has been proposed.
To study the effect of therapeutic intervention on the improvement of the rhythmicity of non-nutritive and nutritive sucking in premature newborns and on the suck central pattern generator. Stimulation of the breast zone was performed in two premature newborns by means of the Vojta method. Intraoral pressure was measured during non-nutritive and nutritive sucking before and after this therapeutic intervention. The maximum negative pressures generated during individual sucks and the intervals between sucks were analysed. The stimulation of the breast zone using the Vojta method seems to have no impact on the duration of individual sucking episodes. However, a significant improvement in the rhythmicity and regularity of sucking was observed in both newborns: the coefficient of quartile deviation for the intervals decreased from 15% and 11% to 13% and 6%, respectively, and for the maximum negative pressures it decreased from 24% and 27% to 9% and 19%, respectively. Additionally, the median value of the maximum negative pressure decreased in both newborns: from -39 and -37 mmHg to -45 and -60 mmHg, respectively. The stimulation of the breast zone using the Vojta method seems to have a direct impact on the central pattern generator, which improves the rhythmicity as well as the regularity of both non-nutritive and nutritive sucking.
30 July 2024 in Biocybernetics and Biomedical Engineering
Pleural manometry enables the assessment of physiological abnormalities of lung mechanics associated with pleural effusion. Applying pleural manometry, we found small pleural pressure curve oscillations resembling the pulse tracing line. The aim of our study was to characterize the oscillations of pleural pressure curve (termed here as the pleural pressure pulse, PPP) and to establish their origin and potential significance. This was an observational cross-sectional study in adult patients with pleural effusion who underwent thoracentesis with pleural manometry. The pleural pressure curves recorded prior to and during fluid withdrawal were analyzed. The presence of PPP was assessed in relation to the withdrawn pleural fluid volume, lung expandability, vital and echocardiographic parameters, and pulmonary function testing. A dedicated device was developed to compare the PPP to the pulse rate. Fifty-four patients (32 women) median age 66.5 (IQR 58.5–78.7) years were included. Well visible and poorly visible pressure waves were detected in 48% and 35% of the patients, respectively. The frequency of PPP was fully concordant with the pulse rate and the peaks of the oscillations reflected the period of heart diastole. PPP was more visible in patients with a slower respiratory rate (p = 0.008), a larger amount of pleural effusion, and was associated with a better heart systolic function assessed by echocardiography (p < 0.05). This study describes a PPP, a new pleural phenomenon related to the cyclic changes in the heart chambers volume. Although the importance of PPP remains largely unknown, we hypothesize that it could be related to lung atelectasis or lower lung and visceral pleura compliance.