Larysa Shylkova

Larysa Shylkova

Auto-generated profile, based on publicly available information

Larysa Shylkova

Associate Professor of the "Electrical Machines" Department of National Technical University "Kharkiv Polytechnic Institute

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
SSSergii Shevchenko
Sergii Shevchenko
EOEniola Olubakinde
Eniola Olubakinde
DDDmytro Danylchenko
Dmytro Danylchenko
INIhor Nazarenko
Ihor Nazarenko
NSNatalia Savchenko
Natalia Savchenko
LSLarysa Shylkova
Larysa Shylkova
This paper reports a study into the influence of the main design parameters of power transmission lines on energy losses associated with the corona discharge; a method has been devised to reduce them. The structure of the split-phase wire, the distance to the ground, and between the centers of the phases of the line are determined at the design stage. Based on these structural parameters, the value of specific energy losses associated with the corona discharge is calculated. Studying the impact exerted on the amount of losses by each structural parameter makes it possible at the design stage to determine the structure of a power transmission line (PTL) with low energy losses. Reducing energy loss when transporting it along the line is one of the most important issues in the strategy for the development of the energy industry at the stage of the "green transition". It has been established that most structural parameters have a weak effect on the values of corona losses, and, if there is a significant impact, the implementation of such solutions leads to a large increase in the cost of constructing an overhead transmission line. Based on the analysis of the results of calculations of corona losses in power transmission lines, it was determined that the corona losses in the middle phase of the transmission line are much greater than in the extreme phases. That has made it possible to devise a method for reducing power corona losses associated with the alignment of the capacities of all phases of PTL. This effect is achieved by calculating, based on the developed method, the splitting step of the middle phase of PTL. The calculation of the splitting step is based on the preliminary determination of the capacity of the extreme phases and the substitution of calculated values in the resulting expression for the splitting step. The possibility of such a reduction in corona losses should significantly increase the energy efficiency of AC power transmission lines, especially in areas with large periods of different weather that provoke the occurrence of a corona discharge on the wires of their phases. This circumstance causes an increase in this type of power loss.

8 September 2025 in Proceedings of the European Wave and Tidal Energy Conference
Verified
Journal Article
Closed access
PDF file
ODOleksii Duniev
Oleksii Duniev
AYAndrii Yehorov
Andrii Yehorov
AMAndrii Masliennikov
Andrii Masliennikov
LSLarysa Shylkova
Larysa Shylkova
MSMario Stamann
Mario Stamann
ODOleksandr Dobzhanskyi
Oleksandr Dobzhanskyi
This study explores new designs of linear generators intended for wave energy conversion systems based on transverse magnetic flux machines (TFM) with permanent magnets. The main focus is on developing new, highly efficient designs of linear generators for wave energy, operating at low speeds. The developed wave energy converters function as direct-drive machines, where the generator's translator is directly connected to the buoy. The working element performs a reciprocating motion, converting wave energy into mechanical energy, which is then transferred to the generator. As a result, the multi-pole TFM generator demonstrates high energy conversion efficiency even at low speeds. This eliminates the need for complex and unreliable hydraulic systems with compressors, simplifying the wave energy conversion system's design and improving its overall reliability. Based on previous research on cylindrical transverse magnetic flux machines with a disk structure, conducted in close collaboration with Germany's Otto-von-Guericke University, a theoretical analysis was performed and successfully validated through laboratory experiments. The experimental data confirmed the efficiency of the proposed generator concept. The findings from previous research were applied to linear types of electric machines, which were proposed and improved in the current study for use in wave energy conversion systems. One of the key achievements of this study was the introduction of a generator design that replaced the I-shaped core (the stator magnetic shunt) with an additional E-shaped core. This allowed the use of a double translator, located both inside and outside the stator core. This double translator and stator core design makes the generator more compact and increases the machine's power. The study also determined the optimal number, size and shape of stator cores to achieve the best magnetic field saturation, which further increased the generator's specific power. As a result, a new, promising design for a three-phase linear direct-drive generator with a nominal power of 2.3 kW and a translator speed of 1 m/s was designed. The generator's magnetic system has an outer diameter of 220 mm and a stator core length of 1 meter. At this translator speed, the system efficiency reached approximately 80%, which is a significant improvement compared to traditional high-speed hydraulic systems. The study's results also confirmed the scalability of the proposed generator design for use in high-power wave energy conversion systems. Such systems can be decentralized and operate in parallel along the shoreline, creating a network for converting ocean wave energy. Moreover, this research significantly contributes to the development of sustainable energy systems, offering an efficient, scalable, and innovative approach to harnessing wave energy. The new linear direct-drive generator designs not only reduce energy conversion losses compared to high-speed hydraulic indirect-drive systems but also promote decentralized production and the advancement of renewable energy sources. The research project results described above have received funding through the EURIZON project, which is funded by the European Union under grant agreement No.871072.

30 March 2026 in Electrical Engineering and Power Engineering
Verified
Journal Article
Open access
LSL.V. Shylkova
L.V. Shylkova
OMO.S. Mykhailychenko
O.S. Mykhailychenko
Purpose. The aim of the work is to conduct theoretical research and develop a methodology for determining the optimal operating slip value to minimize electrical losses under varying load conditions on the induction motor rotor shaft. Methodology. The research was conducted using the fundamentals of mathematical modeling theory for a generalized AC electrical machine, classical optimization methods, the basics of automated control theory, loss minimization techniques in induction motor drives, and methods for the interpolation and approximation of calculated data. Findings. A methodology has been developed for determining the optimal operating slip value to minimize electrical losses under varying rotor shaft load conditions in a quasi-steady-state mode of induction motor operation. A universal objective function for minimizing electrical losses in the induction motor as a function of slip frequency has been obtained. In the process of solving the optimization problem using classical single-variable optimization methods, an expression for the optimal slip frequency was derived, as well as the relationships between current magnitudes and the parameters of the induction motor stator and rotor winding phases. These were obtained based on the conventional mathematical description of a generalized AC electrical machine for its steady-state operation. The effectiveness of the proposed methodology has been proven using the example of an AIR225M2 induction motor with a power rating of 55 kW, for which the electrical loss dependence in a quasi-steady-state mode under a static load of Mc = 0.5Mnom was obtained. It was established that the optimal slip value for this induction motor is s = 0.038. Originality. For induction motors of various power ratings, a universal objective function has been derived to minimize electrical losses as a function of slip frequency. This function enables the determination of a performance characteristic representing the dependence of the maximum attainable efficiency on the load torque on the shaft for induction motors of any power range. Practical value. The research findings can be implemented in induction motor drive systems equipped with rotor speed sensors to enable automated self-regulation of the motor speed. This ensures the rotor operates at the optimal slip value across the entire load range of the driven mechanism.