Yuying Zhang

Yuying Zhang

Auto-generated profile, based on publicly available information

Yuying Zhang

Electric Power Research Institute of State Grid Xinjiang Electric Power Co., Ltd., Urumqi, Xinjiang 830011, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 March 2012 in The Astrophysical Journal
Verified
Journal Article
Open access
DWDaniel R. Wik
Daniel R. Wik
CSCraig L. Sarazin
Craig L. Sarazin
YZYu-Ying Zhang
Yu-Ying Zhang
WBWayne H. Baumgartner
Wayne H. Baumgartner
RMRichard F. Mushotzky
Richard F. Mushotzky
TCTracy E. Clarke
Tracy E. Clarke

7 November 2024 in European Journal of Operational Research
Verified
Journal Article
Closed access
WWWanpeng Wang
Wanpeng Wang
SDShiming Deng
Shiming Deng
YZYuying Zhang
Yuying Zhang

23 December 2025 in Omega
Verified
Journal Article
Closed access
YZYuying Zhang
Yuying Zhang
SDShiming Deng
Shiming Deng
WWWanpeng Wang
Wanpeng Wang

27 September 2020
Verified
Conference Paper
Closed access
HQHanbing Qu
Hanbing Qu
PZPu Zhao
Pu Zhao
Bo WangBo Wang
Bo Wang
YJYujian Jia
Yujian Jia
YZYuying Zhang
Yuying Zhang
XWXiaowei Wang
Xiaowei Wang
Based on the boundary characteristic and frequency characteristic of cable, a protection method for VSC-HVDC cable is proposed in this paper, which only uses the single-end transient current signal. First, the frequency components of the currents at the DC-side and AC-side of the DC boundary are extracted by means of S transform, and the magnitude of the high frequency components of DC-side current is employed to detect the fault. Then, the ratio of the magnitude of the high frequency components of the DC- and AC-side currents is calculated to identify the internal fault from the close-up external fault. Finally, the ratio of the high and low frequency components of the DC-side current is calculated to identify the internal fault from the opposite external fault. This protection method is verified on basis of a two-terminal VSC-HVDC model with EMTDC/PSCAD. Various types of faults are simulated, and the simulation results show that this method can identify the internal faults under different conditions rapidly, while can ignore the external faults reliably.

1 January 2013
Verified
Conference Paper
Closed access
BZBo Zeng
Bo Zeng
XYXu Yuang
Xu Yuang
YZYuying Zhang
Yuying Zhang
Jianhua ZhangJianhua Zhang
Jianhua Zhang
WLWenxia Liu
Wenxia Liu
JDJun Dong
Jun Dong
Coordinating electricity sales with DSM implementation at planning stage after the integration of commercial energy services have become a significant issue for the decision-makers of utilities. Under this background, a novel Grid-side Integrated Resource Planning (GIRP) paradigm is proposed in this paper. Through the identification of key elements induced by the energy service and the interdependence of decision-making of the main grid and its affiliated energy service companies (ESCOs), a bilevel coordinated planning model is developed to achieve globally optimal investment by making use of the synergetic effect. A bee colony complementary hybrid algorithm (BCCA) is also proposed by introducing nonlinear complementarity function to tackle the inefficiency of solving bilevel optimization problems. The results of case study indicate the superiority of GIRP in terms of its better economic benefits and environmental effects and also the improved efficiency of the proposed algorithm.