This paper presents a novel pilot protection scheme of DC cable line in voltage-source-converter (VSC) based multi-terminal DC (MTDC) grids, which utilizes a novel phase-mode transformation to decouple the bipolar DC cable current into six mode and it uses the stationary wavelet transform to extract the modulus maxima of fault initial traveling waves current (FITWC). With accurate amplitude and polarities of the FITWC being collected from the fault-detection devices located at each terminal, the proposed scheme can correctly determine the faulty segment and the faulty pole. In this paper, the ratio of amplitudes between sixth mode forward and backward travelling wave currents is used to judge the faulty segment and the polarity of fifth mode forward travelling wave current is used to identify the faulty pole. A four-terminal VSC-based MTDC grid was built in PSCAD/EMTDC to evaluate the performance of the fault-protection scheme. Simulation results for different cases demonstrate that the proposed protection scheme is robust against noise, and has been tested successfully for fault resistance of up to 400 Ω. Since the scheme merely needs the characteristics of FITWCs, the practical difficulties of detecting subsequent travelling waves are avoided. Moreover, only the state signal is needed to send to the other side in proposed scheme, so low communication speed can satisfy the requirement of relay protection and it does not need the data synchronization seriously.
The increasing use of modern measuring devices, such as Feeder Terminal Units (FTUs), on power networks can provide multiple types of information for fault location on distribution systems. Using these devices, in this paper, a novel automatic matrix-based algorithm for the identification and isolation of faulted feeder sections on distribution systems is proposed. The algorithm works in two stages: the first stage automatically identifies the radial feeders that make up the whole system and represents the feeders’ topology in matrix form; and the second stage automatically identifies the faulted section of the identified feeder and opens the relevant switches to isolate it. The algorithm can be applied to single and multiple faults, as it operates using measuring device information and detecting the status of switch devices. It does not require any electrical parameters and it is not affected by the fault type or fault resistance. The algorithm was thoroughly tested using a large distribution system and was found to efficiently identify and isolate the faulted feeder section in each case.
This paper proposes a fault-location method for voltage-source converter (VSC)-based high-voltage direct current (VSC-HVDC) systems. This method relies on the current frequency components generated by faults in the cable, and requires the arrival time of the frequency components at two terminals. The S transform is a time–frequency analysis tool that is superior to the wavelet transform in some respects. Therefore, the S transform was employed to determine the arrival time in this paper. To obtain a reliable criterion, a novel phase-mode transform method for bipolar cables was developed, and the propagation characteristics of the current frequency components through out the cable were analyzed. A two-terminal VSC-HVDC system was modeled in power system computer aided design/electromagnetic transients including DC (PSCAD/EMTDC). Various faults under different conditions were simulated on the basis of this model, and the simulation results verified a high accuracy, robustness against fault-resistance, and noise immunity of the proposed method.
We have demonstrated a compact, 4.7 W green laser based on an electrically pumped vertical external-cavity surface emitting laser through intracavity frequency doubling. The overall wall-plug efficiency (electrical to green) was 18.3%. The power fluctuations were measured to be over a 2 h time period.
Based on the boundary characteristic and frequency characteristic of cable, a protection method for VSC-HVDC cable is proposed in this paper, which only uses the single-end transient current signal. First, the frequency components of the currents at the DC-side and AC-side of the DC boundary are extracted by means of S transform, and the magnitude of the high frequency components of DC-side current is employed to detect the fault. Then, the ratio of the magnitude of the high frequency components of the DC- and AC-side currents is calculated to identify the internal fault from the close-up external fault. Finally, the ratio of the high and low frequency components of the DC-side current is calculated to identify the internal fault from the opposite external fault. This protection method is verified on basis of a two-terminal VSC-HVDC model with EMTDC/PSCAD. Various types of faults are simulated, and the simulation results show that this method can identify the internal faults under different conditions rapidly, while can ignore the external faults reliably.
With the rapid development of integrated energy systems (IES) towards integration and marketization, the collaborative planning of multi-energy entities has become a research hotspot. However, in real-world market environments, various energy entities often face information asymmetry and competitive interests, posing significant challenges to the optimal scheduling of the system. To address the incomplete information and competitive constraints among multiple energy hubs (EH) within IES, this paper constructs a multi-entity game planning model that accounts for environmental costs and carbon trading mechanisms. The model employs Bayesian game methods to handle the incomplete information among EH and analyzes the dynamic interactive behaviors of market entities under different strategies through multilateral incomplete information evolutionary game theory. Meanwhile, this paper incorporates carbon trading mechanisms along with the coupling technologies of power-to-gas (P2G) and carbon capture systems (CCS) to balance the economic efficiency and environmental protection. Additionally, in response to investment uncertainty, the real options theory is utilized for evaluation, and then a multi-entity incomplete information planning model is constructed, which is solved by using a nested algorithm proposed in this paper. This approach balances the interests of various entities and enhances the comprehensive long-term investment returns considering options. Simulation results demonstrate that the model effectively reflects the game behaviors among multi-energy entities under incomplete information, yielding optimized scheduling solutions that closely align with real-world scenarios. It improves economic benefits while reducing environmental pollution, providing theoretical foundations and methodological support for the planning of integrated energy systems involving multiple entities in electricity market environments.