9 May 2023 in International Journal of Modelling and Simulation
Total hip arthroplasty (THA) is a common procedure that is performed for elderly people who suffer from hip pain and other hip-related problems. THA is an operation where an artificial joint is implanted in the femur and acts as the hip joint. THA has seen advancement to a greater extent in the 20th century. In this work, a novel hip implant design is proposed based on the existing literature data. The hip implants were provided with radial clearance between the head and stem junction. This implant design is analyzed by applying a walking gait that has been clinically prerecorded. Linear and volumetric wear rates are estimated at the head-stem junction, head-liner, and liner to acetabulum using Archard’s wear law. Total deformation, von Mises stress, contact stress, linear and volumetric wear rates were reported. The volumetric wear rate was found to be less than the existing literature, achieving the goal of increasing the life expectancy of the total hip prosthesis. The maximum wear rate is found at the head-stem junction for press-fit. It is observed that when the acetabular cup and femoral head are made of CoCr (Cobalt-Chromium) alloy, the liner with Ultra high molecular weight polyethylene (UHMWPE) and the stem with titanium alloy have a lesser wear rate when compared to other material combinations. Further, it is also found that the fatigue life of Ti (Titanium) alloy is higher than that of CoCr alloy and Ti alloy material combinations have the maximum factor of safety.
17 December 2019 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
The structural vibration in conventional machine tools which are generally made of cast iron may lead to poor surface finish of the machined components. This has led to the investigations on alternative materials for machine tool structures such as concrete, polymer concrete and epoxy granite which have higher damping properties but lesser Young's modulus. However, higher static stiffness with higher damping is essential for improving the static and dynamic characteristics of machine tool structures. Hence, this work focuses on replacing the vertical machining centre base made of cast iron with steel reinforced epoxy granite to improve the structural static stiffness. A finite element model of the above base is developed and validated against the experimental data obtained using modal analysis. The validated numerical approach is applied for investigating the seven progressive design configurations of base reinforced with steel. It is found that the epoxy granite base of Design configuration-7 with L-channels has significantly reduced the deformation by 56 and 36% considering milling and drilling operations, respectively, in comparison to cast iron base. Further, the natural frequencies of the above configuration are higher in all the modes (by more than 50%) under consideration than those of the existing cast iron structure. Therefore, the proposed configuration of base is a viable alternative for the existing base in order to achieve higher structural damping. The novelty of the present work is the design of epoxy granite vertical machining centre base using steel reinforcements to improve structural rigidity with ease of manufacturing.
5 July 2024 in Journal of Materials Engineering and Performance
28 November 2023 in Environmental Science and Pollution Research
31 July 2024 in Journal of Mechanics in Medicine and Biology
9 October 2023 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
AAArun Thiyagarajan Arunachalam
Arun Thiyagarajan Arunachalam
The structural vibrations experienced by traditional machine tools made up of cast iron (CI) or cast steel material lead to premature failure of the cutting tool and poor surface finish on the manufactured components. Steel-reinforced epoxy granite (SREG), an alternate material to CI, improves the static and dynamic characteristics of the machine tool structure. However, the addition of steel reinforcement in SREG affects the damping characteristics of epoxy granite (EG). The present work focuses on optimizing both EG and steel reinforcement of the vertical machining centre column to achieve favourable damping characteristics. Initially, parametric analysis is performed to arrive at an optimum configuration of only the EG column. Then, steel reinforcement is integrated into the EG column, and topology optimization is carried out with the objective of maximizing the stiffness and natural frequencies of the SREG column while minimizing the mass of the reinforcement. The multiple design configurations for steel reinforcement evolved from topology optimization are numerically investigated using finite element analysis. The scaled-down prototype of the finalized model was fabricated, after which the dynamic characteristics of the proposed SREG column are measured and compared with that of existing CI and SREG columns. The results revealed six-fold and three-fold improvements in dynamic stiffness along X - and Y -directions, respectively, and a 33% reduction in the mass of steel reinforcement than the existing SREG column.