Kalayarasan M

Dr. Kalayarasan M


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2023 in International Journal of Modelling and Simulation
Verified
Journal Article
Open access
JRJonathan Reginald
Jonathan Reginald
KMKalayarasan M
Kalayarasan M
Chethan K NChethan K N
Chethan K N
DPDhanabal P
Dhanabal P
Total hip arthroplasty (THA) is a common procedure that is performed for elderly people who suffer from hip pain and other hip-related problems. THA is an operation where an artificial joint is implanted in the femur and acts as the hip joint. THA has seen advancement to a greater extent in the 20th century. In this work, a novel hip implant design is proposed based on the existing literature data. The hip implants were provided with radial clearance between the head and stem junction. This implant design is analyzed by applying a walking gait that has been clinically prerecorded. Linear and volumetric wear rates are estimated at the head-stem junction, head-liner, and liner to acetabulum using Archard’s wear law. Total deformation, von Mises stress, contact stress, linear and volumetric wear rates were reported. The volumetric wear rate was found to be less than the existing literature, achieving the goal of increasing the life expectancy of the total hip prosthesis. The maximum wear rate is found at the head-stem junction for press-fit. It is observed that when the acetabular cup and femoral head are made of CoCr (Cobalt-Chromium) alloy, the liner with Ultra high molecular weight polyethylene (UHMWPE) and the stem with titanium alloy have a lesser wear rate when compared to other material combinations. Further, it is also found that the fatigue life of Ti (Titanium) alloy is higher than that of CoCr alloy and Ti alloy material combinations have the maximum factor of safety.

16 April 2019 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
PDF file
PVPrabhu Raja Venugopal
Prabhu Raja Venugopal
KMKalayarasan M
Kalayarasan M
PTPr Thyla
Pr Thyla
PMPv Mohanram
Pv Mohanram
MNMahendrakumar Nataraj
Mahendrakumar Nataraj
HSHarshad Sonawane
Harshad Sonawane
Higher damping with higher static stiffness is essential for improving the static and dynamic characteristics of machine tool structures. The structural vibration in conventional machine tools, which are generally made up of cast iron and cast steel, may lead to poor surface finish and the dimensional inaccuracy in the machined products. It leads to the investigation of alternative machine tool structural materials such as concrete, polymer concrete, and epoxy granite. Although epoxy granite has a better damping capacity, its structural stiffness (Young's modulus) is one-third as compared to cast iron. Therefore, the present work represents optimization of the structural design of the vertical machining center column by introducing various designs of steel reinforcement in the epoxy granite structure to improve its static and dynamic characteristics using experimental and numerical approaches. A finite element model of the existing cast iron vertical machining center column has been developed and validated against the experimental data obtained using modal analysis. Furthermore, finite element models for various epoxy granite column designs have been developed and compared with the static and dynamic characteristics of cast iron column. A total of nine design configurations for epoxy granite column with steel reinforcement are evolved and numerical investigations are carried out by finite element analysis. The proposed final configuration with standard steel sections has been modeled using finite element analysis for an equivalent static stiffness and natural frequencies of about 12–20% higher than cast iron structure. Therefore, the proposed finite element model of epoxy-granite-made vertical machining center column can be used as a viable alternative for the existing column in order to achieve higher structural damping, equivalent or higher static stiffness and, easy and environmental-friendly manufacturing process.

30 November 2023 in Cogent Engineering
Verified
Journal Article
Open access
KMKalayarasan M
Kalayarasan M
JRJonathan Reginald
Jonathan Reginald
JCJohn Valerian Corda
John Valerian Corda
PDP. Dhanbal
P. Dhanbal
PJPrathik S Jain
Prathik S Jain
Chethan K NChethan K N
Chethan K N

5 June 2024 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
AAAdhiyamaan Arivazhagan
Adhiyamaan Arivazhagan
KMKalayarasan M
Kalayarasan M
BKBanu Pradheepa Kamarajan
Banu Pradheepa Kamarajan
AVAthul Menon V
Athul Menon V
AGAshish Paul G
Ashish Paul G
NVNeo Tarun Venugopal
Neo Tarun Venugopal

28 November 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
DPDhanabal Palanisamy
Dhanabal Palanisamy
KMKalayarasan M
Kalayarasan M
KTKavin Thangaraju
Kavin Thangaraju
VCVenkatesh Chenrayan
Venkatesh Chenrayan
Kiran ShahapurkarKiran Shahapurkar
Kiran Shahapurkar
CMCHANDRU MANIVANNAN
CHANDRU MANIVANNAN

31 July 2024 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
KMKalayarasan M
Kalayarasan M
PDP. Dhanabal
P. Dhanabal
Shankar SubramaniamShankar Subramaniam
Shankar Subramaniam
Chethan K NChethan K N
Chethan K N
MMM. Manikandan
M. Manikandan