François Laurent Emilien Usseglio-Viretta

François Laurent Emilien Usseglio-Viretta

Auto-generated profile, based on publicly available information

François Laurent Emilien Usseglio-Viretta

Center for Energy Conversion & Storage Systems, National Renewable Energy Laboratory, Golden, Colorado 80401, United States of America

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
FUFrancois L. E. Usseglio-Viretta
Francois L. E. Usseglio-Viretta
Andrew M. ColclasureAndrew M. Colclasure
Andrew M. Colclasure
AMAashutosh N. Mistry
Aashutosh N. Mistry
KCKoffi Pierre Yao Claver
Koffi Pierre Yao Claver
FPFezzeh Pouraghajan
Fezzeh Pouraghajan
KSKandler Smith
Kandler Smith
Battery performance is strongly correlated with electrode microstructural properties. Of the relevant properties, the tortuosity factor of the electrolyte transport paths through microstructure pores is important as it limits battery maximum charge/discharge rate, particularly for energy-dense thick electrodes. Tortuosity factor however, is difficult to precisely measure, and thus its estimation has been debated frequently in the literature. Herein, three independent approaches have been applied to quantify the tortuosity factor of lithium-ion battery electrodes. The first approach is a microstructure model based on three-dimensional geometries from X-ray computed tomography (CT) and stochastic reconstructions enhanced with computationally generated carbon/binder domain (CBD), as CT is often unable to resolve the CBD. The second approach uses a macro-homogeneous model to fit electrochemical data at several rates, providing a separate estimation of the tortuosity factor. The third approach experimentally measures tortuosity factor via symmetric cells employing a blocking electrolyte. Comparisons have been made across the three approaches for 14 graphite and nickel-manganese-cobalt oxide electrodes. Analysis suggests that if the tortuosity factor were characterized based on the active material skeleton only, the actual tortuosities would be 1.35–1.81 times higher for calendered electrodes. Correlations are provided for varying porosity, CBD phase interfacial arrangement and solid particle morphology.

1 December 2013 in Journal of Power Sources
Verified
Journal Article
Closed access
JVJulie Villanova
Julie Villanova
JLJérôme Laurencin
Jérôme Laurencin
PCPeter Cloetens
Peter Cloetens
PBPierre Bleuet
Pierre Bleuet
GDGérard Delette
Gérard Delette
FUFrançois Usseglio-Viretta
François Usseglio-Viretta

7 January 2020 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
AMAashutosh N Mistry
Aashutosh N Mistry
FUFrançois Laurent Emilien Usseglio-Viretta
François Laurent Emilien Usseglio-Viretta
Andrew M. ColclasureAndrew M. Colclasure
Andrew M. Colclasure
KSKandler Smith
Kandler Smith
PMPartha P. Mukherjee
Partha P. Mukherjee
Conventionally, battery electrodes are rationalized as homogeneous reactors. It proves to be an erroneous interpretation for fast transients, where mass transport limitations amplify underlying heterogeneities. Given the lack of observability of associated fast spatiotemporal dynamics, redox activity in inhomogeneous electrodes is superficially explored. We resort to a physics-based description to examine the extreme fast charging of lithium-ion battery electrodes. Representative inhomogeneity information is extracted from electrode tomograms. We discover such electrodes to undergo preferential intercalation, localized lithium plating and nonuniform heat generation as a result of distributed long- and short-range interactions. The spatial correlations of these events with the underlying inhomogeneity are found to be nonidentical. Investigation of multiple inhomogeneity fields reveals an exponential scaling of plating severity and early onset in contrast to the homogeneous limit. Anode and cathode inhomogeneities couple nonlinearly to grow peculiar electrodeposition patterns. These mechanistic insights annotate the complex functioning of spatially nonuniform electrodes.

1 May 2020 in Electrochimica Acta
Verified
Journal Article
Closed access
FUF.L.E. Usseglio-Viretta
F.L.E. Usseglio-Viretta
WMW. Mai
W. Mai
Andrew M. ColclasureAndrew M. Colclasure
Andrew M. Colclasure
MDM. Doeff
M. Doeff
EYEongyu Yi
Eongyu Yi
KSK. Smith
K. Smith

1 June 2020 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
FUFrançois Laurent Emilien Usseglio-Viretta
François Laurent Emilien Usseglio-Viretta
DFDonal Finegan
Donal Finegan
Andrew M. ColclasureAndrew M. Colclasure
Andrew M. Colclasure
Thomas M.M. HeenanThomas M.M. Heenan
Thomas M.M. Heenan
DADaniel P Abraham
Daniel P Abraham
KSKandler Smith
Kandler Smith
To sustain the continuous high-rate charge current required for fast charging of electric vehicle batteries, the ionic effective diffusion coefficient of the electrodes must be high enough to avoid the electrode being transport limited. Tortuosity factor and porosity are the two microstructure parameters that control this effective diffusion coefficient. While different methods exist to experimentally measure or calculate the tortuosity factor, no generic relationship between tortuosity and microstructure presently exists that is applicable across a large variety of electrode microstructures and porosities. Indeed, most relationships are microstructure specific. In this work, generic relationships are established using only geometrically defined metrics that can thus be used to design thick electrodes suitable for fast charging. To achieve this objective, an original, discrete particle-size algorithm is introduced and used to identify and segment particles across a set of 19 various electrode microstructures (nickel-manganese-cobalt [NMC] and graphite) obtained from X-ray computed tomography (CT) to quantify parameters such as porosity, particle elongation, sinuosity, and constriction, which influence the effective diffusion coefficient. Compared to the widely used watershed method, the new algorithm shows less over-segmentation. Particle size obtained with different numerical methods is also compared. Lastly, microstructure-tortuosity relationship and particle size and morphology analysis methods are reviewed.

1 June 2014 in Journal of Power Sources
Verified
Journal Article
Closed access
FUF. Usseglio-Viretta
F. Usseglio-Viretta
JLJ. Laurencin
J. Laurencin
GDGerard DELETTE
Gerard DELETTE
JVJ. Villanova
J. Villanova
PCP. Cloetens
P. Cloetens
DLD. Leguillon
D. Leguillon