Christian Richter

Christian Richter

Auto-generated profile, based on publicly available information

Christian Richter

Institute for Organic Chemistry and Chemical Biology Goethe University Frankfurt Max-von-Laue-Strasse 7 60438 Frankfurt am Main Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2021 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
SSSridhar Sreeramulu
Sridhar Sreeramulu
CRChristian Richter
Christian Richter
HBHannes Berg
Hannes Berg
MMMaria A. Wirtz Martin
Maria A. Wirtz Martin
BCBetül Ceylan
Betül Ceylan
HSHarald Schwalbe
Harald Schwalbe
SARS‐CoV‐2 contains a positive single‐stranded RNA genome of approximately 30 000 nucleotides. Within this genome, 15 RNA elements were identified as conserved between SARS‐CoV and SARS‐CoV‐2. By nuclear magnetic resonance (NMR) spectroscopy, we previously determined that these elements fold independently, in line with data from in vivo and ex‐vivo structural probing experiments. These elements contain non‐base‐paired regions that potentially harbor ligand‐binding pockets. Here, we performed an NMR‐based screening of a poised fragment library of 768 compounds for binding to these RNAs, employing three different 1H‐based 1D NMR binding assays. The screening identified common as well as RNA‐element specific hits. The results allow selection of the most promising of the 15 RNA elements as putative drug targets. Based on the identified hits, we derive key functional units and groups in ligands for effective targeting of the RNA of SARS‐CoV‐2.

14 August 2020 in ChemBioChem
Verified
Journal Article
Open access
PDF file
OBOliver Binas
Oliver Binas
VJVanessa de Jesus
Vanessa de Jesus
TLTom Landgraf
Tom Landgraf
AVAlbrecht Eduard Völklein
Albrecht Eduard Völklein
JMJason Martins
Jason Martins
HSHarald Schwalbe
Harald Schwalbe
We report here the nuclear magnetic resonance 19F screening of 14 RNA targets with different secondary and tertiary structure to systematically assess the druggability of RNAs. Our RNA targets include representative bacterial riboswitches that naturally bind with nanomolar affinity and high specificity to cellular metabolites of low molecular weight. Based on counter‐screens against five DNAs and five proteins, we can show that RNA can be specifically targeted. To demonstrate the quality of the initial fragment library that has been designed for easy follow‐up chemistry, we further show how to increase binding affinity from an initial fragment hit by chemistry that links the identified fragment to the intercalator acridine. Thus, we achieve low‐micromolar binding affinity without losing binding specificity between two different terminator structures.

3 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
RTRobert Tannenberg
Robert Tannenberg
MPMartin Paul
Martin Paul
BRBettina Röder
Bettina Röder
SGSantosh Lakshmi Gande
Santosh Lakshmi Gande
SSSridhar Sreeramulu
Sridhar Sreeramulu
Michael G. WellerMichael G. Weller
Michael G. Weller
Cardiac vascular diseases, especially acute myocardial infarction (AMI), are one of the leading causes of death worldwide. Therefore cardio-specific biomarkers such as cardiac troponin I (cTnI) play an essential role in the field of diagnostics. In order to enable rapid and accurate measurement of cTnI with the potential of online measurements, a chemiluminescence-based immunosensor is presented as a proof of concept. A flow cell was designed and combined with a sensitive CMOS camera allowing sensitive optical readout. In addition, a microfluidic setup was established, which achieved selective and quasi-online cTnI determination within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer and demonstrated cTnI measurements in the concentration range of 2–25 µg/L. With the optimized system, a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) was achieved. Furthermore, the selectivity of the immunosensor was investigated with other recombinant proteins, such as cTnT, and cTnC, at a level of 16 µg/L. No cross-reactivity could be observed. Measurements with diluted blood plasma and serum resulted in an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively.

17 March 2014 in Nano Letters
Verified
Journal Article
Closed access
DLDomenik Liße
Domenik Liße
CRChristian P. Richter
Christian P. Richter
CDChristoph Drees
Christoph Drees
OBOliver Birkholz
Oliver Birkholz
CYChangjiang You
Changjiang You
JPJacob Piehler
Jacob Piehler

2 June 2015 in Angewandte Chemie
Verified
Journal Article
Closed access
PDF file
IBIrene Bessi
Irene Bessi
HJHendrik R. A. Jonker
Hendrik R. A. Jonker
CRChristian Richter
Christian Richter
HSHarald Schwalbe
Harald Schwalbe

6 December 2012 in ACS Chemical Biology
Verified
Journal Article
Closed access
CYChangjiang You
Changjiang You
SWStephan Wilmes
Stephan Wilmes
CRChristian P. Richter
Christian P. Richter
OBOliver Beutel
Oliver Beutel
DLDomenik Liße
Domenik Liße
JPJacob Piehler
Jacob Piehler