Rahul Bhat

Rahul Bhat

Auto-generated profile, based on publicly available information

Rahul Bhat

IIT Bombay, Mumbai, India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RRRishabh Raj
Rishabh Raj
BRBoggavarapu Sai Ram
Boggavarapu Sai Ram
RBRahul Bhat
Rahul Bhat
GUGreeshma Mohan Unniachanparambil
Greeshma Mohan Unniachanparambil
SKShrikrishna V. Kulkarni
Shrikrishna V. Kulkarni
Energy losses during the magnetization process of soft magnetic laminations depend on the excitation waveform. Manufacturers of magnetic materials may not provide losses for different excitation waveforms. This may affect the accuracy of the predicted losses which are used to estimate the performance of electrical equipment during the predesign stage. Thus, a characterization tool which is capable of measuring hysteresis loops under controlled magnetization is required. Digital characterization systems available in literature use expensive commercial power amplifiers. In this work, a cost-effective power amplifier circuit is developed and interfaced with a LabVIEW program to characterize soft magnetic materials. The measurements for a sinusoidal excitation from the proposed setup are validated with those from a standard commercial measuring setup. The system is also used to measure hysteresis loops for arbitrary magnetization conditions (magnetic flux density ( B) with harmonics). The proposed setup can operate over a frequency range 35-500 Hz. A small Epstein frame is also designed for measurements at higher frequencies (>200 and <; 500 Hz). A provision is also made to predict three components of dynamic hysteresis losses at any frequency in the above range using the loss separation approach. This capability of the setup enables the user to predict the losses at frequencies beyond the capability of the tool. The predicted losses using this algorithm are validated with measured losses. The proposed setup is cost-effective and can be developed easily using basic electronic components.

18 May 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RBRahul Krishna Bhat
Rahul Krishna Bhat
SKS. V. Kulkarni
S. V. Kulkarni
The Axial Magnetic Field (AMF) type contact is utilized in Vacuum Interrupters (VIs) due to its effectiveness in current interruption. This paper deals with the study of eddy current phenomenon occurring in the AMF VIs. The residual AMF beyond current zero is directly the result of eddy currents in the contact plate and thus is dependent on the contact plate geometry. Considering that the contact plate is analogous to a disk winding, an analytical formulation is developed to compute the eddy current decay constant as a function of contact plate parameters. The analytical predictions are verified using FEM simulations of the step response of a circular plate placed in uniform magnetic field. A linear relationship is established between the contact plate parameters and the eddy current decay constant. The analytical formulation is then used to predict the residual flux decay constant in the context of AMF contact model simulations. A coil-type AMF contact is analyzed using Finite Element Method (FEM) simulations and parametric studies are carried out to study the effect of the contact opening velocity and radial slots on distribution of the contact gap AMF. The results in this work can enable quicker assessment of contact parameters.

1 December 2019 in Chemical Data Collections
Verified
Journal Article
Closed access
KPKiran N. Patil
Kiran N. Patil
RBRahul K. Bhat
Rahul K. Bhat
CBChandrakant D. Bhenki
Chandrakant D. Bhenki
VHVasant Baburao Helavi
Vasant Baburao Helavi

19 March 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RBRahul Bhat
Rahul Bhat
HBHimanshu J. Bahirat
Himanshu J. Bahirat
SKS. V. Kulkarni
S. V. Kulkarni
This article deals with the effects of homopolar magnetic fields on the lifetime of low-current dc vacuum arcs. A homopolar magnetic field is a distribution with the axially symmetric radially oriented field in the contact gap. It is produced when two dipole magnets are kept with the same poles facing each other. Switching experiments are conducted using an off-the-shelf ac vacuum contactor, and the ring magnets are used to set up a homopolar magnetic field in the contact gap. The arcing times are measured for currents varying from 1 to 30 A with voltages up to 100 V and magnetic surface strengths from 0.34 to 0.43 T. The tests are performed with the fixed contact of the vacuum contactor connected to positive as well as negative polarity. It is observed that the arcing time values are lesser in the presence of magnetic field with the fixed contact at the negative polarity due to asymmetry in the placement of the ring magnets. Finite element method (FEM) simulations are performed to examine the magnetic field distribution in the contact gap. The ratio of radial-to-axial magnetic field components in the contact gap decreases with increasing strength of magnets in the present experimental arrangement. It correlates well with the observed arcing time trends against the variation in the strength of magnets and the polarity of the fixed contact. The present article shows the potential of homopolar magnetic field in the development of dc vacuum contactors and interrupters without the need to create an artificial current zero using forced commutation.

18 May 2018 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
RBRahul Bhat
Rahul Bhat
SKShrikrishna V. Kulkarni
Shrikrishna V. Kulkarni
The SWASTIK type radial magnetic field (RMF) contact design is widely used in vacuum interrupters. The mutually perpendicular petal limbs are a unique feature of this contact design. The focus of this work is to relate the Lorentz force acting on the arc with petal dimensions through closed‐form expressions. Considering the petal limbs as equivalent to finite current carrying conductors, analytical equations are derived to compute the magnetic flux density at any point in space. The results are verified by using finite‐element method (FEM) simulations of rail electrodes. The expressions are then used to compute the Lorentz force on the arc in SWASTIK contacts. The analytical predictions are compared with three‐dimensional FEM simulations of a CAD model of the contacts. Applicability of the analytical results is investigated in the context of parametric variation of the radius, length and position of the arc and temporal variation of the contact current. The present work can be used in the first iteration of contact petal design. It is also applicable for the design of rail gun geometries.