Yongjae Park

Yongjae Park

Auto-generated profile, based on publicly available information

Yongjae Park

Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YPYongjae Park
Yongjae Park
SHSu-Hyun Han
Su-Hyun Han
WBWooseok Byun
Wooseok Byun
JKJi-Hoon Kim
Ji-Hoon Kim
HLHyung-Chul Lee
Hyung-Chul Lee
SKSeong-Jin Kim
Seong-Jin Kim
We present a real-time electroencephalogram (EEG) based depth of anesthesia (DoA) monitoring system in conjunction with a deep learning framework, AnesNET. An EEG analog front-end (AFE) that can compensate ±380-mV electrode DC offset using a coarse digital DC servo loop is implemented in the proposed system. The EEG-based MAC, EEGMAC, is introduced as a novel index to accurately predict the DoA, which is designed for applying to patients anesthetized by both volatile and intravenous agents. The proposed deep learning protocol consists of four layers of convolutional neural network and two dense layers. In addition, we optimize the complexity of the deep neural network (DNN) to operate on a microcomputer such as the Raspberry Pi 3, realizing a cost-effective small-size DoA monitoring system. Fabricated in 110-nm CMOS, the prototype AFE consumes 4.33 μW per channel and has the input-referred noise of 0.29 μVrms from 0.5 to 100 Hz with the noise efficiency factor of 2.2. The proposed DNN was evaluated with pre-recorded EEG data from 374 subjects administrated by inhalational anesthetics under surgery, achieving an average squared and absolute errors of 0.048 and 0.05, respectively. The EEGMAC with subjects anesthetized by an intravenous agent also showed a good agreement with the bispectral index value, confirming the proposed DoA index is applicable to both anesthetics. The implemented monitoring system with the Raspberry Pi 3 estimates the EEGMAC within 20 ms, which is about thousand-fold faster than the BIS estimation in literature.

6 January 2022 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
YPYongjae Park
Yongjae Park
JCJi-Hyoung Cha
Ji-Hyoung Cha
SHSu-Hyun Han
Su-Hyun Han
JPJee-Ho Park
Jee-Ho Park
SKSeong-Jin Kim
Seong-Jin Kim
A capacitively-coupled chopper instrument amplifier (CCIA) for bio-potential monitoring analog front-end (AFE) with auto-calibrated dual positive feedback loops (DPFLs) is presented in this article. The proposed AFE with the DPFL does not only prevent total input impedance degradation by unexpected external and internal parasitic capacitances but also achieves excellent noise efficiency simultaneously. The DPFL consists of a conventional internal positive feedback loop with an attenuator for enhancing calibration resolution and an external positive feedback loop outside of the input chopper to compensate for a large external parasitic capacitance ( $C_{P-EXT}$ ), boosting total input impedance significantly. To precisely determine the feedback factor of the DPFL with respect to parasitic capacitors, an on-chip foreground calibration is also implemented in this work. Fabricated in a 110-nm CMOS process, the prototype AFE consumes 3.83 $\mu \text{W}$ per channel at 1 and 1.5-V supplies and has the input-referred noise of 0.36 $\mu \text{V}_{rms}$ from 0.5 to 300 Hz with the noise efficiency factor of 1.54. The proposed AFE achieves high-input impedances of 15 $\text{G}\Omega $ at 10 Hz and 2 $\text{G}\Omega $ at 50 Hz, even with an additional $C_{P-EXT}$ of 82 pF.

3 October 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
JCJi-Hyoung Cha
Ji-Hyoung Cha
JPJee-Ho Park
Jee-Ho Park
YPYongjae Park
Yongjae Park
HSHyogeun Shin
Hyogeun Shin
KHKyeong Seob Hwang
Kyeong Seob Hwang
SKSeong-Jin Kim
Seong-Jin Kim
This article presents a CMOS microelectrode array (MEA) system with a reconfigurable sub-array multiplexing architecture using the time-division multiplexing (TDM) technique. The system consists of 24,320 TiN electrodes with 17.7 µm-pitch pixels and 380 column-parallel readout channels including a low-noise amplifier, a programmable gain amplifier, and a 10-b successive approximation register analog to digital converter. Readout channels are placed outside the pixel for high spatial resolution, and a flexible structure to acquire neural signals from electrodes selected by configuring in-pixel memory is realized. In this structure, a single channel can handle 8 to 32 electrodes, guaranteeing a temporal resolution from 5kS/s to 20kS/s for each electrode. A 128 × 190 MEA system was fabricated in a 110-nm CMOS process, and each readout channel consumes 81 µW at 1.5-V supply voltage featuring input-referred noise of 1.48 µV rms without multiplexing and 5.4 µV rms with multiplexing at the action-potential band (300 Hz – 10 kHz).

26 February 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
JWJiajia Wu
Jiajia Wu
AAAbraham Akinin
Abraham Akinin
JSJonathan Somayajulu
Jonathan Somayajulu
MLMin S. Lee
Min S. Lee
APAkshay Paul
Akshay Paul
GCGert Cauwenberghs
Gert Cauwenberghs
Advances in brain-machine interfaces and wearable biomedical sensors for healthcare and human-computer interactions call for precision electrophysiology to resolve a variety of biopotential signals across the body that cover a wide range of frequencies, from the mHz-range electrogastrogram (EGG) to the kHz-range electroneurogram (ENG). Existing integrated wearable solutions for minimally invasive biopotential recordings are limited in detection range and accuracy due to trade-offs in bandwidth, noise, input impedance, and power consumption. This article presents a 16-channel wide-band ultra-low-noise neural recording system-on-chip (SoC) fabricated in 65nm CMOS for chronic use in mobile healthcare settings that spans a bandwidth of 0.001 Hz to 1 kHz through a featured sample-level duty-cycling (SLDC) mode. Each recording channel is implemented by a delta-sigma analog-to-digital converter (ADC) achieving 1.0 μ V rms input-referred noise over 1Hz–1kHz bandwidth with a Noise Efficiency Factor (NEF) of 2.93 in continuous operation mode. In SLDC mode, the power supply is duty-cycled while maintaining consistently low input-referred noise levels at ultra-low frequencies (1.1 μ V rms over 0.001Hz–1Hz) and 435 MΩ input impedance. The functionalities of the proposed SoC are validated with two human electrophysiology applications: recording low-amplitude electroencephalogram (EEG) through electrodes fixated on the forehead to monitor brain waves, and ultra-slow-wave electrogastrogram (EGG) through electrodes fixated on the abdomen to monitor digestion.

30 November 2022 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
JKJubin Kang
Jubin Kang
YPYongjae Park
Yongjae Park
JHJung-Hye Hwang
Jung-Hye Hwang
KHKieop Hong
Kieop Hong
ISInsang Son
Insang Son
SKSeong-Jin Kim
Seong-Jin Kim
This letter presents an indirect time-of-flight (iToF) sensor with a tetra pixel architecture to calibrate tap mismatch in a single frame. The proposed tetra pixel architecture is incorporated with four different tap configurations in 2 by 2 pixels to capture eight essential phase data simultaneously and compensate for the tap mismatch by interpolation. The prototype iToF sensor with a VGA pixel array was fabricated in a 110-nm CIS process and fully characterized. The measured non-linearity is less than 1.23% at the tetra configuration, achieving about 59% improvement compared with the conventional 2-tap architecture. The motion artifact is also greatly suppressed thanks to the single frame capturing.

5 April 2023 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
JPJee-Ho Park
Jee-Ho Park
JCJi-Hyoung Cha
Ji-Hyoung Cha
YPYongjae Park
Yongjae Park
SKSeong-Jin Kim
Seong-Jin Kim
In this letter, a 2nd-order 2 -Σ modulator consisting of a voltage-controlled-oscillator-based quantizer (VCOQ) and a current digital-to-analog converter (DAC) with a pulse width modulator (PWM) is presented for the precise acquisition of a wide range photocurrent in an area-and energy-efficient form factor. The proposed 2-modulation realized by the 2nd-order infinite impulse response (IIR) filter on the feedback significantly attenuates the magnitude of input signals, enhancing the DR and linearity. Moreover, an additional differentiator followed by the VCOQ features the negative feedback loop in the 2nd-order Σ modulator, improving noise shaping with no additional current DAC noise. In addition, a 1-bit PWM current DAC substituting the multi-bit current DAC is devised to mitigate the noise from the current DAC, realizing the high resolution of 1 pA with 500 Hz bandwidth. The prototype chip fabricated in a 110-nm CMOS occupies 0.0308 mm2 and achieves Walden FoM of 4.15 pJ/conv.