Ming Xu

Ming Xu

Auto-generated profile, based on publicly available information

Ming Xu

Advanced Technology Institute University of Surrey Guildford Surrey UK

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2023 in Exploration
Verified
Journal Article
Open access
MXMing Xu
Ming Xu
YLYuheng Liu
Yuheng Liu
Kai YangKai Yang
Kai Yang
SLShaoyin Li
Shaoyin Li
MWManman Wang
Manman Wang
YZYunlong Zhao
Yunlong Zhao
As implantable medical electronics (IMEs) developed for healthcare monitoring and biomedical therapy are extensively explored and deployed clinically, the demand for non‐invasive implantable biomedical electronics is rapidly surging. Current rigid and bulky implantable microelectronic power sources are prone to immune rejection and incision, or cannot provide enough energy for long‐term use, which greatly limits the development of miniaturized implantable medical devices. Herein, a comprehensive review of the historical development of IMEs and the applicable miniaturized power sources along with their advantages and limitations is given. Despite recent advances in microfabrication techniques, biocompatible materials have facilitated the development of IMEs system toward non‐invasive, ultra‐flexible, bioresorbable, wireless and multifunctional, progress in the development of minimally invasive power sources in implantable systems has remained limited. Here three promising minimally invasive power sources summarized, including energy storage devices (biodegradable primary batteries, rechargeable batteries and supercapacitors), human body energy harvesters (nanogenerators and biofuel cells) and wireless power transfer (far‐field radiofrequency radiation, near‐field wireless power transfer, ultrasonic and photovoltaic power transfer). The energy storage and energy harvesting mechanism, configurational design, material selection, output power and in vivo applications are also discussed. It is expected to give a comprehensive understanding of the minimally invasive power sources driven IMEs system for painless health monitoring and biomedical therapy with long‐term stable functions.

1 April 2021 in Journal of Power Sources
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
RLRong Liu
Rong Liu
XLXiaolong Li
Xiaolong Li
YWYuanming Wang
Yuanming Wang
YLYang Liu
Yang Liu
GYGuohui Yuan
Guohui Yuan

26 July 2022
Verified
Conference Paper
Closed access
PDF file
XFXinghu Fu
Xinghu Fu
JZJiahao Zhou
Jiahao Zhou
MXMing Xu
Ming Xu
YWYufan Wang
Yufan Wang
WJWa Jin
Wa Jin
WBWeihong Bi
Weihong Bi
In this paper, a FMF sensor with double gourd structure is prepared. The transmission spectrum and mode changes of double gourd structure with different lengths are studied, the temperature sensitivity and linearity of the sensor are analyzed. Five sensors with different FMF lengths are prepared. The waist-enlarged spacing are 0.7cm, 1.0cm, 1.3cm, 1.6cm and 1.9cm, respectively. The FMF length are 4.1cm, 5cm, 5.9cm, 6.8cm and 7.7cm, respectively. The experimental results show that the highest temperature sensitivity of FMF sensor is 86.95pm/℃. There is no one-to-one correspondence between the temperature sensitivity and the length of the sensor.