Evelyn Wenkel

Evelyn Wenkel

Auto-generated profile, based on publicly available information

Evelyn Wenkel

Radiology, Radiology München, München, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
MDMatthias Dietzel
Matthias Dietzel
EWEvelyn Wenkel
Evelyn Wenkel
MHMatthias Hammon
Matthias Hammon
PCPaola Clauser
Paola Clauser
MUMichael Uder
Michael Uder
PBPascal A.T. Baltzer
Pascal A.T. Baltzer

13 November 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
MWMatthias Wetzl
Matthias Wetzl
MDMatthias Dietzel
Matthias Dietzel
SOSabine Ohlmeyer
Sabine Ohlmeyer
MUMichael Uder
Michael Uder
EWEvelyn Wenkel
Evelyn Wenkel

2 February 2024 in European Journal of Radiology
Verified
Journal Article
Closed access
MDMatthias Dietzel
Matthias Dietzel
FLFrederik Bernd Laun
Frederik Bernd Laun
RHRafael Heiss
Rafael Heiss
EWEvelyn Wenkel
Evelyn Wenkel
SBSebastian Bickelhaupt
Sebastian Bickelhaupt
SOSabine Ohlmeyer
Sabine Ohlmeyer

22 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
PPPatrik Pöschke
Patrik Pöschke
EWEvelyn Wenkel
Evelyn Wenkel
CHCarolin C. Hack
Carolin C. Hack
MBMatthias W. Beckmann
Matthias W. Beckmann
MUMichael Uder
Michael Uder
SOSabine Ohlmeyer
Sabine Ohlmeyer
Background: In the German Mammography Screening Program, 62% of ductal carcinoma in situ (DCIS) and 38% of invasive breast cancers are associated with microcalcifications (MCs). Vacuum-assisted stereotactic breast biopsies are necessary to distinguish precancerous lesions from benign calcifications because mammographic discrimination is not possible. The aim of this study was to investigate if breast magnetic resonance imaging (MRM) could assist the evaluation of MCs and thus help reduce biopsy rates. Methods: In this IRB-approved study, 58 women (mean age 58 +/− 24 years) with 59 suspicious MC clusters in the MG were eligible for this prospective single-center trial. Additional breast magnetic resonance imaging (MRI) was conducted before biopsy. Results: The breast MRI showed a sensitivity of 86%, a specificity of 84%, a positive predictive value (PPV) of 75% and a negative predictive value (NPV) of 91% for the differentiation between benign and malignant in these 59 MCs found with MG. Breast MRI in addition to MG could increase the PPV from 36% to 75% compared to MG alone. The MRI examination led to nine additional suspicious classified lesions in the study cohort. A total of 55% (5/9) of them turned out to be malignant. A total of 32 of 59 (54 %) women with suspicious MCs and benign histology were classified as non-suspicious by MRI. Conclusion: An additionally performed breast MRI could have increased the diagnostic reliability in the assessment of MCs. Further, in our small cohort, a considerable number of malignant lesions without mammographically visible MCs were revealed.

6 May 2024 in medRxiv
Verified
Preprint
Open access
PDF file
ALAndrzej Liebert
Andrzej Liebert
HSHannes Schreiter
Hannes Schreiter
LKLorenz A. Kapsner
Lorenz A. Kapsner
JEJessica Eberle
Jessica Eberle
CEChris Ehring
Chris Ehring
SBSebastian Bickelhaupt
Sebastian Bickelhaupt
Background: Virtual contrast-enhanced (vCE) imaging techniques are an emerging topic of research in breast MRI. Purpose: To investigate how different combinations of T1-weighted (T1w), T2-weighted (T2w), and diffusion-weighted imaging (DWI) impact the performance of vCE breast MRI. Materials and Methods: The IRB-approved, retrospective study included 1064 multiparametric breast MRI scans (age:52±12 years) obtained from 2017-2020 (single site, two 3T MRI). Eleven independent neural networks were trained to derive vCE images from varying input combinations of T1w, T2w, and multi-b-value DWI sequences (b-value=50–1500s/mm 2 ). Three readers evaluated the vCE images with regards to qualitative scores of diagnostic image quality, image sharpness, satisfaction with contrast/signal-to-noise-ratio, and lesion/non-mass enhancement conspicuity. Quantitative metrics (SSIM, PSNR, NRMSE, and median symmetrical accuracy) were analyzed and statistically compared between the input combinations for the full breast volume and both enhancing and non-enhancing target findings. Results: The independent test set consisted of 187 cases. The quantitative metrics significantly improved in target findings when multi-b-value DWI sequences were included during vCE training (p<.05). Non-significant effects (p>.05) were observed for the quantitative metrics on the full breast volume when comparing input combinations including T1w. Using T1w and DWI acquisitions during vCE training is necessary to achieve high satisfaction with contrast/SNR and good conspicuity of the enhancing findings. The input combination of T1w, T2w, and DWI sequences with three b-values showed the best qualitative performance. Conclusion: vCE breast MRI performance is significantly influenced by input sequences. Quantitative metrics and visual quality of vCE images significantly benefit when a multi b-value DWI is added to morphologic T1w-/T2w-sequences as input for model training. Key Results: The inclusion of diffusion-weighted imaging significantly improves the conspicuity of lesions/non-mass enhancements and satisfaction with the image contrast in virtual contrast-enhanced breast MRI. The quality of virtual contrast-enhanced breast MRI scans benefits from the inclusion of high-resolution morphologic T1-weighted image acquisitions. Quantitative metrics such as the structural similarity index and peak signal-to-noise ratio calculated over the entire breast volume insufficiently reflect variations in lesion/non-mass enhancement’s individual characteristics.

7 August 2024 in medRxiv
Verified
Preprint
Open access
PDF file
HSHannes Schreiter
Hannes Schreiter
JEJessica Eberle
Jessica Eberle
LKLorenz A. Kapsner
Lorenz A. Kapsner
DHDominique Hadler
Dominique Hadler
SOSabine Ohlmeyer
Sabine Ohlmeyer
ALAndrzej Liebert
Andrzej Liebert
Breast Magnetic Resonance Imaging (MRI) examinations routinely include contrast-agent based dynamic contrast-enhanced (DCE) acquisitions. Expanding the accessibility and personalization of breast MRI might be supported amongst others by advancing non-contrast-enhanced MRI, such as virtual dynamic contrast-enhanced techniques (vDCE) utilizing neural networks. This IRB-approved retrospective study includes n=540 breast MRI examinations acquired on a single 3T MRI scanner. Two 2D U-Net architectures were trained using non-contrast-enhanced MRI acquisitions including T1w, T2w and multi-b-value diffusion weighted imaging acquisitions as inputs and either a single (SCO-Net) or multiple (MCO-Net) time points of a DCE series as ground truth. The neural networks predicted a vDCE series corresponding to five consecutive DCE time points. Across all time points, no significant differences in structural similarity index (SSIM) could be found between the SCO-Net and MCO-Net, both achieving a mean SSIM of 0.86. For peak-signal-to-noise-ratio and normalized root-mean-square error, significantly better results could be observed for the MCO-Net reaching scores of 24.42dB and 0.087 respectively. Comparison of manual segmentations of findings on DCE and vDCE images reached a DICE score of 0.61 and an intersection over union (IoU) of 0.47 without significant differences between SCO-Net and MCO-Net. These findings suggest a technical feasibility of generating vDCE image series from unenhanced input acquisitions using neural networks. However, the analysis does not allow drawing any conclusion on the clinical assessment of lesion specific curve kinetics, which need to be assessed prior determining on the feasibility of deriving diagnostically meaningful enhancement characteristics in individual lesions.