Emilian Ceuca

Emilian Ceuca

Auto-generated profile, based on publicly available information

Emilian Ceuca

University "1 Decembrie 1918", Alba Iulia, Romania, Department of Informatics

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FDFlorin Draghici
Florin Draghici
Gheorghe BrezeanuGheorghe Brezeanu
Gheorghe Brezeanu
Gheorghe PristavuGheorghe Pristavu
Gheorghe Pristavu
Razvan PascuRazvan Pascu
Razvan Pascu
MBMarian Badila
Marian Badila
ECEmilian Ceuca
Emilian Ceuca
This paper presents a high-temperature probe suitable for operating in harsh industrial applications as a reliable alternative to low-lifespan conventional solutions, such as thermocouples. The temperature sensing element is a Schottky diode fabricated on 4H-SiC wafers, with Ni as the Schottky metal, which allows operation at temperatures up to 400 °C, with sensitivities over 2 mV/°C and excellent linearity (R2 > 99.99%). The temperature probe also includes dedicated circuitry for signal acquisition and conversion to the 4 mA–20 mA industrial standard output signal. This read-out circuit can be calibrated for linear response over a tunable temperature detection range. The entire system is designed for full electrical and mechanical compatibility with existing conventional probe casings, allowing for seamless implementation in a factory’s sensor network. Such sensors are tested alongside standard thermocouples, with matching temperature monitoring results, over several months, in real working conditions (a cement factory), up to 400 °C.

21 December 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
MFMarius Fisca
Marius Fisca
Mihail Ioan AbrudeanMihail Ioan Abrudean
Mihail Ioan Abrudean
Vlad MuresanVlad Muresan
Vlad Muresan
ICIulia Clitan
Iulia Clitan
MUMihaela-Ligia UNGUREŞAN
Mihaela-Ligia UNGUREŞAN
ECEmilian Ceuca
Emilian Ceuca
The work proposes an original method for modeling and simulating the triggering of 110 kV interconnection power lines in case of common faults, such as transient or persistent faults. Urban and industrial areas, surrounding urban areas, require a high energy consumption that is being supplied through 110 kV overhead power lines, responsible for distributing power to the industrial and domestic consumers. High voltage distribution power lines are most prone to failure, due to their exposure, affecting a large number of consumers if a fault occurs. Faults of power lines in service certify that currently there is no perfectly controllable operation mode in terms of load rating, environmental factors, insulation resistance, or mechanical resistance, which would allow total avoidance of faults, it is only possible to reduce the impact they have on the network as a whole. Mathematical models have been developed to determine the experimental voltage and current responses describing the fault propagation, expressed as a 7th-degree polynomial curve, as a second-order transfer function or as the Gaussian model type. By comparing these mathematical models, the most probable answers that can lead to the development of a control structure for rapid identification of a fault were obtained, with the possibility of triggering the line protection relay. In the final part of the manuscript, the viability of applying artificial intelligence techniques, for the approached fault management application, is proven. The developed control structure evaluates the nature of the fault and determines a faster reaction of the line protection causing an increase in the performance of the distribution service.

1 May 2007
Verified
Conference Paper
Closed access
ECE. Ceuca
E. Ceuca
EOE. Olteanu
E. Olteanu
RJR. Joldes
R. Joldes
Such additional electronics results in a need for more electrical energy in automobiles and other vehicles. Because of this increase in electrical load, higher power demands are being placed on automotive alternator systems. It would, therefore, be desirable to provide a means by which the power output capability of an alternator can be increased. In this paper the author presents several solutions for improving the performances of power equipment, and mainly, of power sources from automotive. Still, considering the broad spectrum of the problem and the complexity of the domain, the solutions proposed by the author represent just a small part of the multitude of possible approaches of this theme and a starting point for further developments of these solutions because the present, high-reactance Lundell-type alternators with diode rectifiers and field control are widely used in the automotive industry.

1 May 2007
Verified
Conference Paper
Closed access
ECE. Ceuca
E. Ceuca
EOE. Olteanu
E. Olteanu
RJR. Joldes
R. Joldes
Circuit simulation is a powerful tool for circuit design and evaluation, and, over the years, many computer programs have been developed for this purpose. Most of these programs are designed so that the commonly used circuit elements are incorporated within the program, and the user can call them in the circuit file following certain syntax rules and keywords specified by the program designer. However, incorporation of a new element by the user is generally impossible, or only allowed in a limited manner by modification of the model equations of an existing element. This situation reduces the flexibility offered to the user for solving new problems.