Bastian Latsch

Dr. Bastian Latsch

orcid
Postdoctoral Researcher at Technische Universität Darmstadt

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Bastian LatschBastian Latsch
Bastian Latsch
NSNiklas Schäfer
Niklas Schäfer
MGMartin Grimmer
Martin Grimmer
ODOmar Ben Dali
Omar Ben Dali
OMOmid Mohseni
Omid Mohseni
MKMario Kupnik
Mario Kupnik
Detecting human movement is crucial for the control of lower limb wearable robotics designed to assist daily activities or rehabilitation tasks. Sensorized insoles present a viable option for extracting control inputs, such as gait events and the corresponding phases, essential for regulating the magnitude and timing of assistance. Given their highly sensitive piezoelectric response to dynamic loading, ferroelectrets emerge as a cost-effective solution for customizing sensors suitable for these autonomous systems. Within this study, an insole with four ferroelectret sensors is 3D-printed monolithically from polylactic acid (PLA) onto bulk films of the same material through seamless thermal fusion. Sensor and insole are characterized through a testing machine and by conducting human walking experiments on an instrumented treadmill. The testing machine results indicate suitable sensor performance for the application in wearable robotics concerning the sensitivity, minimal detectable change, hysteresis, drift, and repeatability. Walking experiments reveal the insole’s capability to detect gait events such as heel strikes with minimal variability and on average 16 ms faster compared to the reference of vertical ground reaction forces across all walking speeds above 1 m/s. The peak sensor outputs strongly relate to the reference while both exhibit a linear (R-squared > 95%) increase corresponding to walking speed. In conclusion, study findings demonstrate the feasibility of PLA-based ferroelectrets as customized insole sensors for event detection in gait analysis, enabling assessment of human biomechanics with minimal impact on the natural gait and control of autonomous wearable robotics, such as exoskeletons.

19 February 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MRMaurice Rohr
Maurice Rohr
JHJad Haidamous
Jad Haidamous
NSNiklas Schäfer
Niklas Schäfer
SSStephan Schaumann
Stephan Schaumann
Bastian LatschBastian Latsch
Bastian Latsch
Christoph Hoog AntinkChristoph Hoog Antink
Christoph Hoog Antink
Hand gestures are a natural form of human communication, making gesture recognition a sensible approach for intuitive human-computer interaction. Wearable sensors on the forearm can be used to detect the muscle contractions that generate these gestures, but classification approaches relying on a single measured modality lack accuracy and robustness. In this work, we analyze sensor fusion of force myography (FMG) and electromyography (EMG) for gesture recognition. We employ piezoelectric FMG sensors based on ferroelectrets and a commercial EMG system in a user study with 13 participants to measure 66 distinct hand movements with 10ms labelling precision. Three classification tasks, namely flexion and extension, single finger, and all finger movement classification, are performed using common handcrafted features as input to machine learning classifiers. Subsequently, the evaluation covers the effectiveness of the sensor fusion using correlation analysis, classification performance based on leave-one-subject-out-cross-validation and 5x2cv-t-tests, and its effects of involuntary movements on classification. We find that sensor fusion leads to significant improvement (42% higher average recognition accuracy) on all three tasks and that both sensor modalities contain complementary information. Furthermore, we confirm this finding using reduced FMG and EMG sensor sets. This study reinforces the results of prior research about the effectiveness of sensor fusion by performing meticulous statistical analyses, thereby paving the way for multi-sensor gesture recognition in assistance systems.

21 June 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
SSStephan Schaumann
Stephan Schaumann
Bastian LatschBastian Latsch
Bastian Latsch
NSNiklas Schäfer
Niklas Schäfer
ODOmar Ben Dali
Omar Ben Dali
JSJulian Seiler
Julian Seiler
MKMario Kupnik
Mario Kupnik
Recognizing human movement intention is key to control wearable robotics for assistance such as in the elderly and rehabilitation. Piezoelectric sensors, in particular highly sensitive ferroelectrets (FEs), qualify for the assessment of subtle muscle movements using force myography (FMG). In contrast to electromyography (EMG), which measures electrical muscle activity, FMG measures the mechanical muscle response to overcome issues in electrode placement and skin preparation. We employ 3D-printed polypropylene FE sensor patches for FMG adjacent to EMG electrodes as a reference at the lower limb of six young unimpaired participants performing sit-to-stand movements. The activity onsets of FMG and EMG are systematically compared at the quadriceps femoris and visually verified using a high-speed camera. The average time difference (35 $\pm$ 50 ms) aligns with the known electromechanical muscle delay. Notably, our results demonstrate that FMG can provide an early indicator for the activity onset significantly before the EMG (on average 263 $\pm$ 90 ms earlier) in this scenario due to the possibility to measure passive muscle deformation. In addition, the signal-to-noise ratio (SNR) of the FE signal (53 dB) exceeds that of the EMG (39 dB) during the maximum muscle activity, while the average variability is slightly larger for FE (22%) compared to EMG (17%). In conclusion, our customizable FE sensors prove to be suitable for motion intention detection and promise an advance in wearable assistive devices, such as active prostheses and exoskeletons, to support people in need.

5 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
Bastian LatschBastian Latsch
Bastian Latsch
FHFelix Herbst
Felix Herbst
MSMark Suppelt
Mark Suppelt
JSJulian Seiler
Julian Seiler
SSStephan Schaumann
Stephan Schaumann
MKMario Kupnik
Mario Kupnik
Plantar pressure measurement, or pedobarography, is an essential tool for analyzing human motion in healthy individuals and patients. Across the reviewed literature, sensor insoles are motivated as wearable, mobile solutions for assessing pressure distribution in applications including diabetic foot monitoring, rehabilitation guidance, assistive device control, and sports performance analysis. This review evaluates the current state of the art with particular attention to sensor technologies, sensor quantity and placement, participant cohorts, and reference standards. The focus lies on original works with innovative designs, preferably supported by ambulation experiments. The modalities covered include resistive, capacitive, inductive, piezoelectric, triboelectric, and optical sensing approaches. We identify a lack of proper sensor calibration, gait-based verification, and human study validation, and propose a gold standard based on testing machines and instrumented treadmills to ensure comparability across studies. The bidirectional interaction between insole insertion and foot-sole mechanics is examined, with tissue stiffness identified as a key source of uncertainty in sensor signals. Guidelines are provided for sensor dimensions and unobtrusive insole designs to foster natural gait. Finally, future directions include the development of multimodal sensors to compensate for limitations of individual modalities and the emerging trend of multiaxial sensing for capturing shear components in pressure distributions.

17 February 2025 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
NSNiklas Schäfer
Niklas Schäfer
JSJulian Seiler
Julian Seiler
Bastian LatschBastian Latsch
Bastian Latsch
MKMario Kupnik
Mario Kupnik
PBPhilipp Beckerle
Philipp Beckerle
Haptic motion guidance has the potential to advance assistive technologies that support humans in movement tasks. This study systematically evaluates wrist rotation guidance methods in a 2×2 repeated measures design using a wearable vibrotactile feedback device. In two tasks, we investigate the benefits of encoding the current target distance in the cue strength and conveying additional information about the target location by incorporating a tactile illusion known as phantom sensation. For a directional response task, we analyze reaction times and error rates, and for an angle targeting task, we examine rise time, settling time, and maximum overshoot of the normalized step responses. These objective criteria are complemented by subjective user ratings that assess the intuitiveness and ease of interpreting the vibrotactile cues. Feedback methods incorporating an adaptive amplitude perform significantly better in the angle targeting task compared to those using a constant amplitude. Additional improvements can be achieved by combining the adaptive amplitude with phantom sensations, including an average additional 24.3% reduction in rise time. Furthermore, more than half of the participants rate this combination as their favorite method. Altogether, the results underline the potential of incorporating phantom sensations in vibrotactile wrist guidance, thereby contributing to the advancement of wearable haptics in assistive applications.

5 September 2020
Verified
Book Chapter
Open access
PDF file
JSJulian Seiler
Julian Seiler
NSNiklas Schäfer
Niklas Schäfer
Bastian LatschBastian Latsch
Bastian Latsch
RCRomol Chadda
Romol Chadda
MHMarkus Hessinger
Markus Hessinger
MKMario Kupnik
Mario Kupnik
We present a wearable vibrotactile feedback device consisting of four linear resonant actuators (LRAs) that are able to generate virtual stimuli, known as phantom tactile sensation, for human-robot interaction. Using an energy model, we can control the location and intensity of the virtual stimuli independently. The device consists of mostly 3D-printed rigid and flexible components and uses commercially available haptic drivers for actuation. The actuators have a rated frequency of 175 Hz which is close to the highest skin sensitivity regarding vibrations (150 to 300 Hz). Our experiment was conducted with a prototype consisting of two bracelets applied to the forearm and upper arm of six participants. Eight possible circumferential angles were stimulated, of which four originated from real actuators and four were generated by virtual stimuli. The responses given by the participants showed a nearly linear relationship within $$\pm {10}{^\circ }$$ ± 10 ∘ for the responded angle against the presented stimulus angle. These results show that phantom tactile sensation allows for an increase of spatial resolution to design vibrotactile interfaces for human-robot interaction with fewer actuators.