This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.66 years were included. Measurements were conducted for hip and knee joint angles in the sagittal plane, with three repetitions per participant analyzed using both systems. The D-Wall system employed a 3D Kinect V2 camera and force platform, while Kinovea used 2D video-based motion analysis. The results demonstrated excellent agreement between the two systems, with intra-class correlation coefficients (ICC) ranging from 0.79 to 0.99. For the knee joint, the test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.98 (95% CI: 0.95–0.99) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.88 (95% CI: 0.79–0.94) for the D-Wall on the left side. For the hip joint, test-retest ICC values were 0.99 (95% CI: 0.97–0.99) for Kinovea and 0.94 (95% CI: 0.88–0.97) for the D-Wall on the right side, and 0.98 (95% CI: 0.97–0.99) for Kinovea and 0.93 (95% CI: 0.87–0.97) for the D-Wall on the left side. Bland–Altman plots confirmed good agreement, with no significant systematic bias observed. Both systems showed statistically insignificant differences (p > 0.05) between measurements, and correlation values ranged from 0.83 to 0.99, indicating strong associations. These findings highlight the high validity and reliability of both TecnoBody D-Wall and Kinovea systems in measuring joint angles during dynamic movements. The comparable accuracy between systems suggests that either system can be effectively utilized in clinical or research settings, depending on specific needs and resource availability.
30 April 2024 in İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi
With the advancement of technology, the effect of auxiliary machines used in rehabilitation is gradually increasing both in the evaluation stage and the rehabilitation stage of the treatment. The important feature of such devices is that they perform both assessment and treatment with the same device. At this stage, TecnoBody (Bergamo, Italy) devices play an active role in both assessment and rehabilitation. In this study, the effectiveness of TecnoBody devices, D-Wall, Walker View 3.0 SCX, and ProKin devices in rehabilitation was analyzed. It is reported in the literature that recently TecnoBody devices have been used significantly in evaluation, proprioceptive and stability tests have been performed with ProKin devices, and balance tests have been performed with the D-Wall device. The D-Wall device was found to be effective in therapies due to its use in rehabilitation, exergame, and biofeedback. It is observed that the Walker View 3.0 SCX device is effective in gait analysis evaluation and gait rehabilitation after surgery, while ProKin devices are effective primarily in proprioceptive, stability, and balance evaluations and then in balance and proprioceptive training. The use of TecnoBody devices in rehabilitation increases the active participation of people in therapy thanks to the visual biofeedback it applies to people, it is effective thanks to the fact that people can direct themselves during exercise and make therapy more fun with games. In addition, thanks to the personalized exercises in the D-Wall device, there are effective exercises to increase the participation of people in daily life activities, especially in neurological rehabilitation. Therefore, the use of TecnoBody devices in rehabilitation is effective.
30 June 2024 in Journal of Education and Recreation Patterns
Virtual reality (VR) is an advanced user-computer interface that includes real-time simulation and interactions through visual and auditory senses. VR is increasingly being used on athletes for assessment and training. Balance refers to maintaining the position of the body's center of gravity. Static and dynamic balance is the basis of postural stability and mobility and is an important skill in sport. Balance impairment increases the risk of falls and is clinically assessed using the Berg Balance Scale. However, more objective methods need to be developed. For this purpose, technologies such as posturography, which measures the center of pressure trajectory, are used. TecnoBody devices play an active role in the assessment and rehabilitation processes. In particular, proprioceptive and stability analyses are performed with ProKin devices, dynamic balance analyses are performed with D-Wall device and audiovisual feedback is provided with exergame. These devices are effective in rehabilitation and can increase patients' interest in treatment. As a result of the studies conducted in the literature review, TecnoBody Prokin has also been used in the field of sports sciences. In the studies conducted with Prokin, it was seen that it was generally used in dynamic and static balance evaluations. However, no studies on TecnoBody's other devices were found in the literature. In addition, in the studies examined, it was seen that TecnoBody devices were used as a evaluation tool instead of being used in exercises. With the advancement of technology, it is thought that TecnoBody devices can be more effective in people through exercise feedback. Keywords: Athlete Balance, Balance, TecnoBody,
1 January 2024 in Turkish Journal of Sport and Exercise
Lateral ankle sprains (LAS) are common in athletes and 40% lead to chronic ankle instability (CAI). CAI is characterised by recurrent sprains and limitation of motion. Our study investigated the relationship between kinesiophobia, foot-ankle function, and physical activity in athletes with chronic ankle instability. In our study, 112 individuals with CAI who have been doing regular sports for at least 5 years were included. Tampa kinesiophobia test, Foot and Ankle Ability Measure (FAAM), and International Physical Activity Questionnaire (Short Version) were administered to the included individuals via Google form. IBM Statistical Package for Social Sciences Version 26.0 (SPSS inc, Chicago, IL, USA) was used. Pearson's test analysis was used in the study, and statistical significance was taken as p ≤ 0.05 for all measurements in two directions. 115 participants (75 males and 40 females) were included in the study. The participants were 20.43±3.921(years) years old, 176.14±9.288(cm) tall, and 67.88±11.571(kg) weight. In addition, the subjects' International Physical Activity Score (Short Version) showed that 34 were inactive, 54 were minimally active, and 27 were very active. There was a moderate negative correlation between the Tampa Kinesiophobia score and FAAM sport and DLA subscores (p<.001). Individuals with increased kinesiophobia scores had decreased Foot and Ankle Ability Measure scores. According to the studies, studies on foot and ankle range of motion, position perception, and balance in individuals with CAI may decrease kinesiophobia.
25 July 2024 in Research in Sport Education and Sciences
Gymnastics is a basic sport branch consisting of eight disciplines and is recommended to be taught to children at an early age. Our study aimed to evaluate the foot biomechanics and static plantar pressure of children aged 5-15 years who were performing rhythmic and artistic gymnastics. The study included 58 (19 Men/39 Women) child gymnasts and aged 5-15 years. Sociodemographic form, static plantar pressure analysis in bipedal position with pedobarography device, hallux valgus angle measurement (HVA), navicular drop test (NDT) and subtalar pronation angle measurement were performed respectively. The measurements were performed in the same way by an experienced expert. IBM Statistical Package for Social Sciences Version 26.0 (SPSS inc, Chicago, IL, USA) statistical programme was used. Tests were analyzed pairwise with Pearson correlation (p ≤ 0.05). The mean age was 7.43±2.37 years, height 124.68±16.97 cm, weight 27.39±11.39 kg and body mass index (BMI) 16.99±3.22 kg/m2. There was no significant difference between weighted and unweighted in NDT results. In pedobarography analysis, hindfoot percentages were higher than forefoot percentages in static bipedal positions. A positive correlation was found between HVA and subtalar angles (p=0.00). In children performing artistic and rhythmic gymnastics, lateral ankle sprain may be observed due to a pronation tendency in subtalar angles. In addition, in the static bipedal position, distortions occurred in the bipedal static force center because the percentage of hindfoot pressure in plantar pressures was higher than the forefoot. Studies with foot-ankle exercises are needed for these.
19 March 2026 in Yalova Üniversitesi Spor Bilimleri Dergisi
Mosaicplasty is an established cartilage repair technique; however, postoperative rehabilitation remains challenging in athletes requiring high neuromuscular control and functional performance. This case study examined the effects of an integrated robotic and sensor-based rehabilitation program using the Cyberdyne Hybrid Assistive Limb Single Joint and TecnoBody systems in a 33-year-old professional soccer player following medial femoral condyle mosaicplasty. The intervention was applied five days per week for three months. Gait parameters, balance, functional mobility, and lower extremity strength were assessed using validated TecnoBody systems and clinical tests. Post-intervention, static balance improved by 19.82% and 13.95% under eyes-open and eyes-closed conditions, respectively, while 10-meter walk and Timed Up and Go test times decreased by 46.40% and 45.89%. Step length increased bilaterally, accompanied by improvements in joint flexion angles and sit-to-stand performance. These findings support the feasibility and potential clinical value of integrated robotic rehabilitation following mosaicplasty in athletes (NCT06516380).