Giuseppe Cantatore

Prof. Giuseppe Cantatore

Restorative Dentistry and Endodontics, Vita-Salute San Raffaele University, Milan, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
MMMauro Mandurino
Mauro Mandurino
FPFrancesca De Palma
Francesca De Palma
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Nicola ScottiNicola Scotti
Nicola Scotti
Alessandro VichiAlessandro Vichi
Alessandro Vichi
Background: This systematic review aims to evaluate the color stability of resin composite CAD/CAM blocks (CCB) when submitted to staining solutions. Methods: A systematic search was performed on different databases (Embase, Medline, Scopus, Web of Science). Search terms were: ‘polymer infiltrated’, ‘polymer-based’, ‘resin nanoceramic’, ‘resin ceramic’, ‘hybrid composite’, ‘hybrid ceramic’, ‘composite ceramic’, ‘resin infiltrated’, ‘CAD-CAM’, ‘CAD/CAM’, ‘color stability’, ‘staining’, ‘staining susceptibility’, ‘color change’, ‘color difference’. Inclusion criteria: in vitro articles published in the English language until 18 September 2022 without initial time restriction evaluating the color stability of CCB when submitted to staining solutions. Exclusion criteria: studies investigating color change induced by smoke or whitening treatments; studies not including a clinical evaluation of the results using the thresholds for color perceptibility and acceptability. Risk of bias assessment using the QUIN tool. Findings: Out of the 378 initially retrieved articles, 19 were included in this review. They investigated 17 different CCBs and different artificial staining by liquid protocols, including coffee, red wine, tea, and cola. CCBs exceeded clinical acceptability thresholds for color shift in 18 out of 19 studies, with a significantly higher color stability than conventional hybrid resin-based composites (RBCs), and a significantly lower color stability than ceramic materials. The identified differences in CCBs in color stability can be attributed to the material’s composition, but also to the heterogeneity of staining procedures. Interpretation and clinical implication: Clinicians should be aware that, although to a lower degree when compared to RBCs used in direct or indirect procedures, CCBs undergo color changes to a higher degree in comparison to ceramic materials.

24 February 2025 in Materials
Verified
Journal Article
Open access
PDF file
MMMauro Mandurino
Mauro Mandurino
SCSilvia Cortili
Silvia Cortili
LCLuca Coccoluto
Luca Coccoluto
KGKatia Greco
Katia Greco
Giuseppe CantatoreGiuseppe Cantatore
Giuseppe Cantatore
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
Objective: To conduct a systematic review on the mechanical properties of 3D printed resin-based composites when compared with those of subtractively manufactured resin-based composites. Materials and Methods: In vitro studies comparing the mechanical properties of additively and subtractively manufactured resin-based composites were sought. A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), was performed on four databases (PubMed, Embase, Web of Science, and Scopus) for articles published until 23 December 2024. The quality of the studies was assessed with the QUIN tool (risk-of-bias tool for assessing in vitro studies conducted in dentistry) and those assessed with a high risk of bias were excluded. Results: Of the 1058 screened articles, 13 were included in this review. A noticeable heterogeneity emerged in the methodologies employed, mainly regarding samples’ fabrication techniques, materials involved, and parameters analyzed. The most investigated mechanical property was fracture resistance, followed by microhardness, flexural strength, and wear behavior. Among the tested materials, the most used 3D printable resins were VarseoSmile Crown Plus (Bego) and Crowntec (Saremco Dental), whereas for the subtractive groups, the most investigated was Brilliant Crios (Coltène). Conclusions: The mechanical properties of 3D printed resins designed for permanent restorations are still lower than those of their subtractively manufactured counterparts. Moreover, in the long term, the degradation processes that inevitably occur might significantly increase their chances of failure.

24 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Uros JosicUros Josic
Uros Josic
Nicola ScottiNicola Scotti
Nicola Scotti
GEGherlone Felice Enrico
Gherlone Felice Enrico
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
Several lubricant materials can be used to model resin-based composites (RBCs) during restorative procedures. Clinically, instruments or brushes are wet with bonding agents (BAs) or modeling liquids (MLs) for sculpturing purposes. However, a knowledge gap exists on their effects on the mechanical properties of RBCs, requiring greater insight. Five databases were searched, including 295 in vitro studies on the use of lubricant materials for modeling RBCs during restorative procedures. Only articles in the English language were included, with no limits on the publication date. The last piece of research was dated 24 March 2022. In total, 16 studies were included in the review process, together with a paper retrieved after screening references. A total of 17 BAs and 7 MLs were investigated. Tensile (n = 5), flexural strength (n = 2), water sorption (n = 2), color stability (n = 8) and translucency (n = 3), micro-hardness (n = 4), roughness (n = 3), degree of conversion (n = 3), and monomer elution (n = 2) tests were carried out. In general, a maximum of 24 h of artificial storage was performed (n = 13), while four papers tested the specimens immediately. The present review identifies the possibilities and limitations of modeling lubricants used during restorative procedures on the mechanical, surface, and optical properties of RBCs. Clinicians should be aware that sculpturing RBCs with modeling resins might influence the composite surface properties in a way that is material-dependent.

25 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
MMMauro Mandurino
Mauro Mandurino
SBSofia Baldani
Sofia Baldani
MPMaria Giacinta Paolone
Maria Giacinta Paolone
Cecilia GoracciCecilia Goracci
Cecilia Goracci
GGGiorgio Gastaldi
Giorgio Gastaldi
Objectives: To conduct a systematic review assessing quantitative enamel loss occurring after orthodontic debonding and clean-up procedures. Materials and Methods: A systematic search following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was performed on different databases (Embase, Medline, Scopus, Web of Science) for papers investigating volumetric enamel loss due to bracket and clear aligner attachment debonding and/or clean-up procedures. Studies investigating in vivo and in vitro articles published in the English language until 16 July 2022 were included. The study selection was then performed by two authors who screened the abstracts independently. Results: Of 421 screened abstracts, 41 articles were selected for full-text analysis. Finally, nine studies were included in this review. No in vivo papers were retrieved. In vitro papers investigated volumetric loss caused by the removal of metal brackets (n = 7), ceramic brackets (n = 1), and both (n = 1). The clean-up procedure varied among all investigations. Impressions at baseline and after debonding/clean-up were superimposed, and the volumes were subtracted using different 3D digital analysis software. Among all included studies, the volumetric loss of enamel ranged from 0.02 ± 0.01 mm3 to 0.61 ± 0.51 mm3 per tooth. Conclusions: Debonding and clean-up procedures produce enamel loss. The debonding/clean-up procedure that is able to cause the least enamel volume loss has yet to be identified.

1 November 2008 in Journal of Endodontics
Verified
Journal Article
Closed access
PDF file
ABAntonio Bonaccorso
Antonio Bonaccorso
Edgar SchäferEdgar Schäfer
Edgar Schäfer
GCGuglielmo Condorelli
Guglielmo Condorelli
Giuseppe CantatoreGiuseppe Cantatore
Giuseppe Cantatore
TTTeresa Roberta Tripi
Teresa Roberta Tripi

14 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
FBFrancesca Boggio
Francesca Boggio
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
Alessandro VichiAlessandro Vichi
Alessandro Vichi
Giuseppe CantatoreGiuseppe Cantatore
Giuseppe Cantatore
Background: To evaluate the effect of different experimental staining procedures on color stability and translucency of a nano-hybrid resin-based composite (RBC). Methods: Forty-eight cylindrical-shaped specimens (10 × 2 mm) were prepared with a nano-hybrid RBC (Clearfil Majesty ES-2) and randomly divided in four groups according to the experimental staining procedure: G1) static immersion in a staining solution (coffee) (44 ± 1 °C); G2) staining cycling between coffee (44 ± 1°C) and distilled water (37 ± 1°C) with an experimental staining machine based on Arduino, an Open Source hardware development platform; G3) staining cycles as in G2 + brushing with a low abrasive toothpaste (Relative Dentin Abrasion RDA = 30) (Elmex Sensitive Professional); G4) staining cycles as in G3, with brushing performed with a very strong abrasive toothpaste (RDA = 90) (Lacult Active). Color parameters were recorded at the baseline (T0) after staining procedures (T1) and repolishing (T2) using a spectrophotometer. Color change (∆E00) and translucency (TP, CR) were evaluated. Data were statistically analyzed (p < 0.05). Results: For ∆E00 after staining, Group 1 showed the highest color change and Group 3 the lowest. All groups were significantly different (p < 0.001) except for Group 2 vs. Group 4; after repolishing, Group 1 was significantly higher than Group 3 (p < 0.001), Group 2 (p < 0.001), and Group 4 (p = 0.003); Group 2 was higher than Group 3 (p < 0.001). For TP variable, after staining procedures, Group 2 was significantly higher than all other groups (p < 0.001), and Group 1 was significantly higher than Group 3 (p < 0.001) and Group 4 (p = 0.007). After repolishing, Group 4 was significantly lower than Group 3 (p = 0.008) and Group 2 (p = 0.027). Repolishing procedure significantly reduced color parameters. Conclusions: The investigated staining procedure induced significant differences in color stability and translucency. The use of a very strong abrasive toothpaste (RDA = 90) induced higher color change than a low abrasive one (RDA = 30). Repolishing procedures are able to partially reduce color change induced by artificial staining procedures.