Elena Stuppia

Dr. Elena Stuppia

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Filippo LaganàFilippo Laganà
Filippo Laganà
RORiccardo Olivieri
Riccardo Olivieri
ESElena Stuppia
Elena Stuppia
Gianluca BarileGianluca Barile
Gianluca Barile
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
Air-coupled ultrasound (ACU) is emerging as a fully non-contact sensing modality in biomedical applications. ACU applications can be broadly classified into two main domains: (i) contactless monitoring of physiological parameters and (ii) assistive aids, robotic perception in unstructured real-world environments, enabling tracking and geometric reconstruction. Advances in electronic materials and sensor design have enhanced ultrasonic sensor characteristics (e.g., bandwidth, directivity, and intensity). In parallel, progress in front-end electronics and signal processing, including artificial intelligence (AI)-assisted analysis, has enhanced ACU performance under low signal-to-noise (SNR) conditions. This review focuses on low-frequency ACU systems, with emphasis on sensor technologies, electronic interfaces, and system architectures that enable non-contact biomedical and robotic applications.

2 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Filippo LaganàFilippo Laganà
Filippo Laganà
RORiccardo Olivieri
Riccardo Olivieri
ESElena Stuppia
Elena Stuppia
Gianluca BarileGianluca Barile
Gianluca Barile
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
Air-coupled ultrasound (ACU) is emerging as a fully non-contact sensing modality in biomedical applications. ACU applications can be broadly classified into two main domains: (i) contactless monitoring of physiological parameters and (ii) assistive aids, robotic perception in unstructured real-world environments, enabling tracking and geometric reconstruction. Advances in electronic materials and sensors design have enhanced ultrasonic sensors characteristics (e.g. bandwidth, directivity, and intensity). In parallel, progress in front-end electronics and signal processing, including artificial intelligence (AI)-assisted analysis, has enhanced ACU performance under low signal-to-noise (SNR) conditions. This review focuses on low-frequency ACU systems, with emphasis on sensor technologies, electronic interfaces, and system architectures that enable non-contact biomedical and robotic applications.

9 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
LMLaura Manin
Laura Manin
ACAntonio Castelliti
Antonio Castelliti
ESElena Stuppia
Elena Stuppia
Filippo LaganàFilippo Laganà
Filippo Laganà
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
Marta GrecoMarta Greco
Marta Greco
Accurate visualization of the plasma membrane is essential for assessing morphological changes induced by experimental perturbations. Scanning electron microscopy (SEM) enables high-resolution imaging of cell surface architecture, but the fixation, dehydration, and drying steps critically affect membrane preservation. Here, we present an improved SEM preparation workflow for two cultured cell models with different growth phenotypes, HepG2 and IM-9, and evaluate the effects of fixation time and drying strategy on plasma membrane preservation. Among the tested conditions, a shorter glutaraldehyde fixation time (15 min) combined with stepwise ethanol-to-HMDS substitution provided the best overall preservation of membrane continuity, cell shape, and surface regularity. Morphometric analysis supported the qualitative SEM observations, and HMDS-processed samples also showed better structural stability during storage under the tested conditions. This workflow provides a simple, reproducible, and cost-effective strategy for SEM-based analysis of cell surface morphology in cultured cell models.