Riccardo Olivieri

Dr. Riccardo Olivieri

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Filippo LaganàFilippo Laganà
Filippo Laganà
RORiccardo Olivieri
Riccardo Olivieri
ESElena Stuppia
Elena Stuppia
Gianluca BarileGianluca Barile
Gianluca Barile
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
Air-coupled ultrasound (ACU) is emerging as a fully non-contact sensing modality in biomedical applications. ACU applications can be broadly classified into two main domains: (i) contactless monitoring of physiological parameters and (ii) assistive aids, robotic perception in unstructured real-world environments, enabling tracking and geometric reconstruction. Advances in electronic materials and sensor design have enhanced ultrasonic sensor characteristics (e.g., bandwidth, directivity, and intensity). In parallel, progress in front-end electronics and signal processing, including artificial intelligence (AI)-assisted analysis, has enhanced ACU performance under low signal-to-noise (SNR) conditions. This review focuses on low-frequency ACU systems, with emphasis on sensor technologies, electronic interfaces, and system architectures that enable non-contact biomedical and robotic applications.

2 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Filippo LaganàFilippo Laganà
Filippo Laganà
RORiccardo Olivieri
Riccardo Olivieri
ESElena Stuppia
Elena Stuppia
Gianluca BarileGianluca Barile
Gianluca Barile
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
Air-coupled ultrasound (ACU) is emerging as a fully non-contact sensing modality in biomedical applications. ACU applications can be broadly classified into two main domains: (i) contactless monitoring of physiological parameters and (ii) assistive aids, robotic perception in unstructured real-world environments, enabling tracking and geometric reconstruction. Advances in electronic materials and sensors design have enhanced ultrasonic sensors characteristics (e.g. bandwidth, directivity, and intensity). In parallel, progress in front-end electronics and signal processing, including artificial intelligence (AI)-assisted analysis, has enhanced ACU performance under low signal-to-noise (SNR) conditions. This review focuses on low-frequency ACU systems, with emphasis on sensor technologies, electronic interfaces, and system architectures that enable non-contact biomedical and robotic applications.

19 December 2025 in IEEE Sensors Reviews
Verified
Journal Article
Open access
RORiccardo Olivieri
Riccardo Olivieri
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
This review provides a comprehensive and structured analysis of electronic interface systems for electrocardiogram (ECG) signal acquisition, with a particular emphasis on the design of analog front-end circuits. These front-end systems represent the first and most critical stage in any ECG acquisition chain, as they must handle biopotential signals that are extremely low in amplitude, bandwidth-limited, and highly susceptible to environmental interference. After the description of general and innovative principles of ECG acquisition, some examples of sensor electrodes, as well as proposed solutions of ECG signal acquisition are given. Starting from electrode technologies, including wet, dry, and textile-based solutions, their impact on interface design is discussed in terms of impedance, motion artifacts, and patient comfort. The fundamental building blocks of ECG front-ends—instrumentation amplifiers, driven-right-leg (DRL) circuits, and filtering stages—are then investigated, highlighting design strategies and innovative proposals. In particular, the fundamental design requirements for amplifiers have been examined: the discussion will be centered on traditional voltage-mode architectures as well as emerging current-mode approaches, analyzing their advantages and limitations in terms of power efficiency, gain stability, and integration capability, as presented in recent literature for ECG interface design. Future perspectives are outlined, covering the role of advanced CMOS technologies in the development and design of analog systems for biosignal monitoring, as well as the needs of electrodes based on nanostructured and biocompatible maerials. Through an in-depth examination of recent literature, we have compared some state-of-the-art solutions and outlined future trends for the development of high-performance, low-power ECG analog acquisition systems, particularly in the context of portable and wearable medical devices.

Verified
Journal Article
Open access
PDF file
RORiccardo Olivieri
Riccardo Olivieri
DCDavide Colaiuda
Davide Colaiuda
Gianluca BarileGianluca Barile
Gianluca Barile
Vincenzo StornelliVincenzo Stornelli
Vincenzo Stornelli
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
This paper presents a novel transistor-level design of a modified second-generation voltage conveyor (VCII), which incorporates two differential current inputs (Y+ and Y−) and gives a voltage output at terminal X that mirrors the sum of these currents. The circuit operation is based on current mirrors that maintain the X terminal in a stable “quiescent” state when no differential current is applied at Y+ and Y−. When a current flows into one of the two inputs, the sum is mirrored into X, providing a summed current measurement. This design, developed in a standard 0.35 μm CMOS transistors technology, ensures circuit high accuracy and robustness. The low power consumption of 24.6 μW makes it well-suited for portable biomedical applications as in environmental fields.

2 September 2025 in Electronics
Verified
Journal Article
Open access
PDF file
RORiccardo Olivieri
Riccardo Olivieri
GLGiuseppe Alessandro Di Lizio
Giuseppe Alessandro Di Lizio
Gianluca BarileGianluca Barile
Gianluca Barile
Vincenzo StornelliVincenzo Stornelli
Vincenzo Stornelli
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
SMShahram Minaei
Shahram Minaei
In this paper a new single-input independent multiple-output universal tunable filter employing second-generation current conveyors (CCII) and second-generation voltage conveyors (VCII) as active elements is presented. The proposed filter has been analyzed at transistor level, using a CMOS standard AMS 0.35 μm technology, and implemented using discrete components based on the commercially available AD844. A detailed mathematical analysis is carried out, considering also parasitic impedances and non-ideal parameters. The low-pass, band-pass, and high-pass responses are simultaneously obtained and experimentally verified at 10 kHz central frequency where the voltage gain is about 27 dB for each output. THD analysis has been performed to evaluate the proposed work.

15 January 2026 in Electronics
Verified
Journal Article
Open access
PDF file
RORiccardo Olivieri
Riccardo Olivieri
TCTobia Carini
Tobia Carini
Gianluca BarileGianluca Barile
Gianluca Barile
Vincenzo StornelliVincenzo Stornelli
Vincenzo Stornelli
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
This work presents a notch filter architecture based on a dual-output second-generation voltage conveyor, designed with a current-mode approach. The proposed topology employs a single frequency-selective LC branch and directly uses the two voltage outputs of the DOVCII to generate a notch response without additional active stages. Analytical expressions for the transfer function, notch frequency, and quality factor are derived, highlighting independent control of the passband gain and notch parameters. A sensitivity analysis demonstrates that the notch frequency depends exclusively on the LC product with half-order sensitivities, while the quality factor is predominantly controlled by a single resistor, resulting in predictable tuning and improved tolerance to passive component variations. Transistor-level analysis of the proposed filter was carried out using a standard AMS 0.35 μm CMOS process and has been validated through both circuit-level simulations and experimental measurements using a DOVCII implementation based on the AD844 current-feedback amplifier. Prototypes operating at 100 kHz and 50 Hz notch frequencies have been implemented, the latter employing a current-mode inductance simulator to avoid bulky passive inductors.