24 June 2021 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
GFGiorgia Fiori
Giorgia Fiori
Fabio FuianoFabio Fuiano
Fabio Fuiano
Andrea ScorzaAndrea Scorza
Andrea Scorza
SCSilvia Conforto
Silvia Conforto
SSSalvatore Andrea SCIUTO
Salvatore Andrea SCIUTO
In recent years, statistical studies highlighted an increasing incidence of cardiovascular diseases (CVD) which reflected on additional costs on the healthcare systems worldwide. Pulse wave velocity (PWV) measurement is commonly considered a CVD predictor factor as well as a marker of Arterial Stiffness (AS), since it is closely related to the mechanical characteristics of the arterial wall. An increase in PWV is due to a more rigid arterial system. Because of the prevalence of the elastic component, in young people the PWV is lower than in the elderly. Nowadays, invasive and non-invasive methods for PWV assessment are employed: there is an increasing attention in the development of non-invasive devices which mostly perform a regional PWV measurement (over a long arterial portion) rather than local (over a short arterial portion). The accepted gold-standard for non-invasive AS measurement is the carotid-femoral PWV used to evaluate the arterial damage, the corresponding cardiovascular risk and to adapt the proper therapy. This review article considers the main commercially available devices underlining their operating principles in terms of sensors, execution mode, pulse waveform acquired, site of measurement, distance and time estimation methods, as well as their main limitations in clinical practice.

25 June 2023 in Actuators
Verified
Journal Article
Open access
PDF file
Gabriele BocchettaGabriele Bocchetta
Gabriele Bocchetta
GFGiorgia Fiori
Giorgia Fiori
SSSalvatore Andrea SCIUTO
Salvatore Andrea SCIUTO
Andrea ScorzaAndrea Scorza
Andrea Scorza
The introduction of smart materials will become increasingly relevant as biomedical technologies progress. Smart materials sense and respond to external stimuli (e.g., chemical, electrical, mechanical, or magnetic signals) or environmental circumstances (e.g., temperature, illuminance, acidity, or humidity), and provide versatile platforms for studying various biological processes because of the numerous analogies between smart materials and biological systems. Several applications based on this class of materials are being developed using different sensing principles and fabrication technologies. In the biomedical field, force sensors are used to characterize tissues and cells, as feedback to develop smart surgical instruments in order to carry out minimally invasive surgery. In this regard, the present work provides an overview of the recent scientific literature regarding the developments in force measurement methods for biomedical applications involving smart materials. In particular, performance evaluation of the main methods proposed in the literature is reviewed on the basis of their results and applications, focusing on their metrological characteristics, such as measuring range, linearity, and measurement accuracy. Classification of smart materials-based force measurement methods is proposed according to their potential applications, highlighting advantages and disadvantages.

29 June 2021 in ACTA IMEKO
Verified
Journal Article
Closed access
FVFederica Vurchio
Federica Vurchio
GFGiorgia Fiori
Giorgia Fiori
ASAndrea Scorza
Andrea Scorza
SSSalvatore Andrea Sciuto
Salvatore Andrea Sciuto
The functional characterization of MEMS devices is relevant today since it aims at verifying the behavior of these devices, as well as improving their design. In this regard, this study focused on the functional characterization of a MEMS microgripper prototype suitable in biomedical applications: the measurement of the angular displacement of the microgripper comb-drive is carried out by means of two novel automatic procedures, based on an image analysis method, SURF-based (Angular Displacement Measurement based on Speeded Up Robust Features, ADMSURF) and FFT-based (Angular Displacement Measurement based on Fast Fourier Transform, ADMFFT) method, respectively. Moreover, the measurement results are compared with a Semi-Automatic Method (SAM), to evaluate which of them is the most suitable for the functional characterization of the device. The curve fitting of the outcomes from SAM and ADMSURF, showed a quadratic trend in agreement with the analytical model. Moreover, the ADMSURF measurements below 1° are affected by an uncertainty of about 0.08° for voltages less than 14 V, confirming its suitability for microgripper characterization. It was also evaluated that the ADMFFT is more suitable for measurement of rotations greater than 1° (up to 30°), with a measurement uncertainty of 0.02°, at 95% of confidence level.

18 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GFGiorgia Fiori
Giorgia Fiori
Fabio FuianoFabio Fuiano
Fabio Fuiano
Andrea ScorzaAndrea Scorza
Andrea Scorza
JGJAN Galo
JAN Galo
SCSilvia Conforto
Silvia Conforto
SSSalvatore Andrea SCIUTO
Salvatore Andrea SCIUTO
Maximum depth of penetration (DOP) is among the most relevant parameters in quality assurance programs for Ultrasound (US) scanners. Nowadays, a generally-accepted protocol for DOP estimation is still awaited and, in common practice, DOP is visually assessed despite the low accuracy. To overcome the eye-based assessment subjectivity, automatic image analysis methods have been proposed in literature. The present work focuses on a novel automatic method, namely the adaptive Signal to Noise Ratio (SNR) threshold method (AdSTM), developed in the MATLAB environment, by comparing it with an existing automatic approach, namely the tangent threshold method (TTM), and the mean judgment of eight observers (naked eye method). The three investigated methods were applied on data acquired from four US scanners for general purpose imaging, equipped with linear, convex, and vector array probes. Tests were carried out in two different configuration settings (raw scanner and default preset working conditions). AdSTM outcomes were tested by means of Monte Carlo Simulations. Most of measurement results were compatible despite the fact that the AdSTM seemed to be more sensitive and faster than the TTM. The results analysis confirms the higher dispersion of the naked eye method in DOP assessment with respect to the proposed automatic methods.

22 November 2024 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
FFFederico Filippi
Federico Filippi
GFGiorgia Fiori
Giorgia Fiori
Gabriele BocchettaGabriele Bocchetta
Gabriele Bocchetta
VBVincenzo La Battaglia
Vincenzo La Battaglia
SMStefano Marini
Stefano Marini
Andrea ScorzaAndrea Scorza
Andrea Scorza
Arterial stiffness is one of the key indicators of cardiovascular diseases, for which an early identification is crucial. Pulse Wave Velocity (PWV) is a widely used parameter to assess arterial stiffness. In clinical practice, it is common use to measure the PWV through the estimation of the Pulse Transit Time (PTT). In this study a comparison among three PTT estimation methods (peak-to-peak, tangent-secant, and cross-correlation) is proposed and applied to waveforms acquired on a novel arterial simulator able to change the stiffness of an arterial surrogate by varying the transmural pressure. After a measurement campaign carried out for several pressure values, the cross-correlation method has been confirmed to be the most robust, with uncertainties below 1.3 %. The operating principle of the arterial simulator has been confirmed since a change in transmural pressure of 25 kPa resulted in a change in PWV mean values of up to 1.7 m/s.

15 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GFGiorgia Fiori
Giorgia Fiori
APAndrada Pica
Andrada Pica
SSSalvatore Andrea SCIUTO
Salvatore Andrea SCIUTO
FMFranco Marinozzi
Franco Marinozzi
Fabiano BiniFabiano Bini
Fabiano Bini
Andrea ScorzaAndrea Scorza
Andrea Scorza
Color Doppler (CD) imaging is widely used in diagnostics since it allows real-time detection and display of blood flow superimposed on the B-mode image. Nevertheless, to date, a shared worldwide standard on Doppler equipment testing is still lacking. In this context, the study herein proposed would give a contribution focusing on the combination of five test parameters to be included in a novel Quality Assessment (QA) protocol for CD systems testing. A first approach involving the use of the Kiviat diagram was investigated, assuming the diagram area, normalized with respect to one of the gold standards, as an index of the overall Doppler system performance. The QA parameters were obtained from the post-processing of CD data through the implementation of custom-written image analysis methods and procedures, here applied to three brand-new high-technology-level ultrasound systems. Experimental data were collected through phased and convex array probes, in two configuration settings, by means of a Doppler flow phantom set at different flow rate regimes. The outcomes confirmed that the Kiviat diagram might be a promising tool applied to quality controls of Doppler equipment, although further investigations should be performed to assess the sensitivity and specificity of the proposed approach.