Vienna rectifiers have gained popularity in recent years for AC to DC power conversion for many industrial applications such as welding power supplies, data centers, telecommunication power sources, aircraft systems, and electric vehicle charging stations. The advantages of this converter are low total harmonic distortion (THD), high power density, and high efficiency. Due to the inherent current control loop in the voltage-oriented control strategy proposed in this paper, good steady-state performance and fast transient response can be ensured. The proposed voltage-oriented control of the Vienna rectifier with a PI controller (VOC-VR) has been simulated using MATLAB/Simulink. The simulations indicate that the input current THD of the proposed VOC-VR system was below 3.27% for 650V and 90A output, which is less than 5% to satisfy the IEEE-519 standard. Experimental results from a scaled-down prototype showed that the THD remains below 5% for a wide range of input voltage, output voltage, and loading conditions (up to 2 kW). The results prove that the proposed rectifier system can be applied for high power applications such as DC fast-charging stations and welding power sources.
Promoting a sustainable and low-carbon energy future through the integration of renewable energy is essential, yet it presents significant challenges due to the intermittent nature of resources such as solar and wind. This paper examines the technological and economic dimensions of AC, DC, and smart grids, concentrating on the optimization of costs, efficiency, stability, and scalability. Smart grids, enhanced by AI, IoT, and blockchain technologies, play a vital role in energy management optimization, predictive maintenance, and secure energy transactions. Furthermore, the incorporation of renewable energy sources, especially photovoltaics, presents challenges including intermittency, voltage fluctuations, and grid congestion. This paper emphasizes the necessity for updated grid codes and policies that guarantee system stability and the effective functioning of renewable energy systems. The implementation of these regulatory frameworks is crucial for facilitating the efficient integration of renewable energy into the grid, ensuring a reliable and secure power supply while advancing sustainability efforts.
Electric vehicles (EVs) are poised to lead the transportation sector as the primary choice of automobile due to their efficiency and environmental benefits. EVs with enhanced autonomy and reduced pricing have become feasible in the market, enabling a gradual transition for higher EV penetration. However, electric vehicles require highly efficient and stabilized charging stations in urban areas to ensure the vehicle’s charging time is not compromised. In this regard, the Vienna rectifier with a voltage-oriented controller (VOC) plays a significant role in improving the power quality of the utility grid for EV battery charger applications. The low stability of the battery charger’s output voltage and current is due to the trial-and-error method used to select the PI controller gains. In order to improve the voltage and current stability, the particle swarm optimization (PSO) technique is used to optimize VOC’s PI controller gains. The code composer studio (CCS) platform integrates the PSO technique for EV battery chargers in the experimental setup. The Vienna rectifier with VOC for EV battery charger is implemented using TMS 320F28337 digital signal controller in the test board. Findings indicate that the PSO optimized VOC improves the output voltage and current stability by 12% compared to the existing trial-and-error technique. Furthermore, the proposed system is tested in an experimental setup that provides input current THD to less than 5% for different load variations (up to 1.5kW) to meet the IEEE-519 standards. Results from simulations and experimental setup verify that the proposed PSO-PI controller-based Vienna rectifier significantly improves EV battery chargers’ output voltage and current stability.
Existing DC fast-charging stations are experiencing power quality issues such as high harmonics in the line current, poor power factor in the input supply, and overloading of distribution transformers, due to the dynamic behavior of charging patterns when it is connected to the power grid. Most of the recent works involve the usage of renewable energy sources to mitigate the issues on the distribution grid. In order to design a mobile plug and play DC fast charging station, solar energy is the best and viable solution to carry out. In this paper, plug and play solar photovoltaic power plant to charge electric vehicles (EVs) is proposed and modelled using MATLAB/Simulink software. The proposed system can act as a mobile power plant. The controller allows the system to charge the battery, whenever there is abundant solar energy. Incoming EVs will be charged directly from the system battery where the charger acts as a rapid charging system. The proposed system can meet the concept of Solar Photovoltaic Rapid Charging Stations (SPRCS), which shows that 80% of charge can be fed to an EV in 10.25 min.
There is a growing need for stability enhancement in modern electrical networks integrated with wind energy, particularly due to different oscillation modes disturbances. Power system stabilizers (PSSs) are used to mitigate oscillations and improve the stability of the power system. This paper presents a comprehensive analysis of single-band PSS1A and multi-band PSS4C (MB-PSS4C) connected to the ST1A excitation system. An efficient approach in the selection of the parameters of MB-PSS4C using Particle Swarm Optimization (PSO) is proposed. A comparative investigation linked to the common Pattern Search and Simplex Search, from previous work, has been conducted to gauge the efficacy of PSO. The generator’s transient stability with considerations of relative power angle (power angle differences), speed deviation, and active power of synchronous generators (SGs) are analyzed. Different wind penetration levels ranging from 36MW to 108 MW are integrated into the network and are investigated. Results demonstrate that PSO-MB-PSS4C connected to ST1A stabilizes the system effectively with reduced settling time while mitigating the peak power angle differences of SGs. Reduced settling time of 1.35 s is observed for wind penetration of 48 MW, with 43.31° peak power angle; while for high wind penetration of 108 MW, the settling time is around 8 s with peak power angle of 43.9°.