Typical electromyogram (EMG) processors estimate EMG signal standard deviation (EMGs) via moving average root mean square (RMS) or mean absolute value (MAV) filters, whose outputs are used in force estimation, prosthesis/orthosis control, etc. In the inevitable presence of additive measurement noise, some processors subtract the noise standard deviation from EMG RMS (or MAV). Others compute a root difference of squares (RDS)—subtract the noise variance from the square of EMG RMS (or MAV), all followed by taking the square root. Herein, we model EMG as an amplitude-modulated random process in additive measurement noise. Assuming a Gaussian (or, separately, Laplacian) distribution, we derive analytically that the maximum likelihood estimate of EMGs requires RDS processing. Whenever that subtraction would provide a negative-valued result, we show that EMGs should be set to zero. Our theoretical models further show that during rest, approximately 50% of EMGs estimates are non-zero. This result is problematic when EMGs is used for real-time control, explaining the common use of additional thresholding. We tested our model results experimentally using biceps and triceps EMG from 64 subjects. Experimental results closely followed the Gaussian model. We conclude that EMG processors should use RDS processing and not noise standard deviation subtraction.

11 April 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ZZZiling Zhu
Ziling Zhu
JLJianan Li
Jianan Li
WBWilliam J. Boyd
William J. Boyd
CMCarlos Martinez-Luna
Carlos Martinez-Luna
CDChenyun Dai
Chenyun Dai
ECEdward Clancy
Edward Clancy
Recent research has advanced two degree-of-freedom (DoF), simultaneous, independent and proportional control of hand-wrist prostheses using surface electromyogram signals from remnant muscles as the control input. We evaluated two such regression-based controllers, along with conventional, sequential two-site control with co-contraction mode switching (SeqCon), in box-block, refined-clothespin and door-knob tasks, on 10 able-bodied and 4 limb-absent subjects. Subjects operated a commercial hand and wrist using a socket bypass harness. One 2-DoF controller (DirCon) related the intuitive hand actions of open-close and pronation-supination to the associated prosthesis hand-wrist actions, respectively. The other (MapCon) mapped myoelectrically more distinct, but less intuitive, actions of wrist flexion-extension and ulnar-radial deviation. Each 2-DoF controller was calibrated from separate 90 s calibration contractions. SeqCon performed better statistically than MapCon in the predominantly 1-DoF box-block task (>20 blocks/minute vs. 8–18 blocks/minute, on average). In this task, SeqCon likely benefited from an ability to easily focus on 1-DoF and not inadvertently trigger co-contraction for mode switching. The remaining two tasks require 2-DoFs, and both 2-DoF controllers each performed better (factor of 2–4) than SeqCon. We also compared the use of 12 vs. 6 optimally-selected EMG electrodes as inputs, finding no statistical difference. Overall, we provide further evidence of the benefits of regression-based EMG prosthesis control of 2-DoFs in the hand-wrist.

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HWHE WANG
HE WANG
KRKiriaki Rajotte
Kiriaki Rajotte
HWHaopeng Wang
Haopeng Wang
CDChenyun Dai
Chenyun Dai
ZZZiling Zhu
Ziling Zhu
ECEdward Clancy
Edward Clancy
To facilitate the broader use of EMG signal whitening, we studied four whitening procedures of various complexities, as well as the roles of sampling rate and noise correction. We separately analyzed force-varying and constant-force contractions from 64 subjects who completed constant-posture tasks about the elbow over a range of forces from 0% to 50% maximum voluntary contraction (MVC). From the constant-force tasks, we found that noise correction via the root difference of squares (RDS) method consistently reduced EMG recording noise, often by a factor of 5–10. All other primary results were from the force-varying contractions. Sampling at 4096 Hz provided small and statistically significant improvements over sampling at 2048 Hz (~3%), which, in turn, provided small improvements over sampling at 1024 Hz (~4%). In comparing equivalent processing variants at a sampling rate of 4096 Hz, whitening filters calibrated to the EMG spectrum of each subject generally performed best (4.74% MVC EMG-force error), followed by one universal whitening filter for all subjects (4.83% MVC error), followed by a high-pass filter whitening method (4.89% MVC error) and then a first difference whitening filter (4.91% MVC error)—but none of these statistically differed. Each did significantly improve from EMG-force error without whitening (5.55% MVC). The first difference is an excellent whitening option over this range of contraction forces since no calibration or algorithm decisions are required.

2 February 2024 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
HWHaopeng Wang
Haopeng Wang
BBBerj Bardizbanian
Berj Bardizbanian
ZZZiling Zhu
Ziling Zhu
HWHe Wang
He Wang
CDChenyun Dai
Chenyun Dai
ECEdward Clancy
Edward Clancy

15 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HWHaopeng Wang
Haopeng Wang
HWHE WANG
HE WANG
CDChenyun Dai
Chenyun Dai
XHXinming Huang
Xinming Huang
ECEdward Clancy
Edward Clancy
Deep neural networks (DNNs) and transfer learning (TL) have been used to improve surface electromyogram (sEMG)-based force estimation. However, prior studies focused mostly on applying TL within one joint, which limits dataset size and diversity. Herein, we investigated cross-joint TL between two upper-limb joints with four DNN architectures using sliding windows. We used two feedforward and two recurrent DNN models with feature engineering and feature learning, respectively. We found that the dependencies between sEMG and force are short-term (<400 ms) and that sliding windows are sufficient to capture them, suggesting that more complicated recurrent structures may not be necessary. Also, using DNN architectures reduced the required sliding window length. A model pre-trained on elbow data was fine-tuned on hand–wrist data, improving force estimation accuracy and reducing the required training data amount. A convolutional neural network with a 391 ms sliding window fine-tuned using 20 s of training data had an error of 6.03 ± 0.49% maximum voluntary torque, which is statistically lower than both our multilayer perceptron model with TL and a linear regression model using 40 s of training data. The success of TL between two distinct joints could help enrich the data available for future deep learning-related studies.