Hazel Louise Mitchell

Mrs. Hazel Louise Mitchell

University of Southampton, Southampton, UK
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2023 in Heliyon
Verified
Journal Article
Open access
FBFlorentin Bulot
Florentin Bulot
Steven OssontSteven Ossont
Steven Ossont
AMAndrew Morris
Andrew Morris
PBPhilip Basford
Philip Basford
NENatasha H.C. Easton
Natasha H.C. Easton
MLMatthew Loxham
Matthew Loxham
Particulate Matter (PM) low-cost sensors (LCS) present a cost-effective opportunity to improve the spatiotemporal resolution of airborne PM data. Previous studies focused on PM-LCS-reported hourly data and identified, without fully addressing, their limitations. However, PM-LCS provide measurements at finer temporal resolutions. Furthermore, government bodies have developed certifications to accompany new uses of these sensors, but these certifications have shortcomings. To address these knowledge gaps, PM-LCS of two models, 8 Sensirion SPS30 and 8 Plantower PMS5003, were collocated for one year with a Fidas 200S, MCERTS-certified PM monitor and were characterised at 2 min resolution, enabling replication of certification processes, and highlighting their limitations and improvements. Robust linear models using sensor-reported particle number concentrations and relative humidity, coupled with 2-week biannual calibration campaigns, achieved reference-grade performance, at median PM2.5 background concentration of 5.5 μg/m3, demonstrating that, with careful calibration, PM-LCS may cost-effectively supplement reference equipment in multi-nodes networks with fine spatiotemporality.

4 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Low-cost Particulate Matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors, but some models of sensors also report Particle Number Concentrations (PNCs) segregated into different PM size ranges. In this study, eight units each of Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors’ to different particle size distributions to quantify and better understand the low-cost sensors performance across a range of relevant environmental ranges. The PNCs reported by the sensors were analysed to characterise sensor-reported particle size distribution, to determine whether sensor-reported PNCs can follow the transient variations of PM observed by the reference instruments and to determine the relative impact of different variables on the performances of the sensors. This study shows that the Alphasense OPC-R1 reported at least five size ranges independently from each other, that the Sensirion SPS30 reported two size ranges independently from each other and that all the size ranges reported by the Plantower PMS5003 were not independent of each other. It demonstrates that all sensors tested here could track the fine temporal variation of PNCs, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it shows that particle size distribution and composition are more impactful on sensor measurements than relative humidity.

6 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HMHazel Louise Mitchell
Hazel Louise Mitchell
SCSimon J Cox
Simon J Cox
HLHugh G. Lewis
Hugh G. Lewis
In order to combat greenhouse gas emissions, the sources of these emissions must be understood. Environmental monitoring using low-cost wireless devices is one method of measuring emissions in crucial but remote settings, such as peatlands. The Figaro NGM2611-E13 is a low-cost methane detection module based around the TGS2611-E00 sensor. The manufacturer provides sensitivity characteristics for methane concentrations above 300 ppm, but lower concentrations are typical in outdoor settings. This study investigates the potential to calibrate these sensors for lower methane concentrations using machine learning. Models of varying complexity, accounting for temperature and humidity variations, were trained on over 50,000 calibration datapoints, spanning 0–200 ppm methane, 5–30 °C and 40–80% relative humidity. Interaction terms were shown to improve model performance. The final selected model achieved a root-mean-square error of 5.1 ppm and an R2 of 0.997, demonstrating the potential for the NGM2611-E13 sensor to measure methane concentrations below 200 ppm.

21 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Low-cost particulate matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and their cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors but some models of sensors also report particle number concentrations (PNC) segregated into different PM size bins. In this study, 8 units of each Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors to different particle size distributions to quantify and better understand the low cost sensors performance across a range of relevant environmental ranges. The PNC reported by the sensors were analysed. This study showed that there is added value in directly using the PNC reported by the sensors instead of the mass concentrations, which could aid the efforts to calibrate these sensors to a known accuracy. It demonstrated that all sensors tested here could track the fine temporal variation of PNC, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it showed that particle size distribution and composition are more impactful on the sensors measurement than relative humidity.

18 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HMHazel Louise Mitchell
Hazel Louise Mitchell
SCSimon J Cox
Simon J Cox
HLHugh G. Lewis
Hugh G. Lewis
Peatlands across the world are vital carbon stores. However, human activities have caused the degradation of many sites, increasing their greenhouse gas emissions and vulnerability to wildfires. Comprehensive monitoring of peatlands is essential for their protection, tracking degradation and restoration, but current techniques are limited by cost, poor reliability and low spatial or temporal resolution. This paper covers the research, development, deployment and performance of a resilient and modular multi-purpose wireless sensor network as an alternative means of monitoring peatlands. The sensor network consists of four sensor nodes and a gateway and measures temperature, humidity, soil moisture, carbon dioxide and methane. The sensor nodes transmit measured data over LoRaWAN to The Things Network every 30 min. To increase the maximum possible deployment duration, a novel datastring encoder was implemented which reduced the transmitted datastring length by 23%. This system was deployed in a New Forest (Hampshire, UK) peatland site for two months and collected more than 7500 measurements. This deployment demonstrated that low-cost sensor networks have the potential to improve the temporal and spatial resolution of peatland emission monitoring beyond what is achievable with traditional monitoring techniques.