A flexible surface acoustic wave (SAW) strain sensor in the frequency range of 162–325 MHz was developed based on a single crystalline LiNbO3 thin film with dual resonance modes, namely, the Rayleigh mode and the thickness shear mode (TSM). This SAW sensor could handle a wide strain range up to ±3500 owing to its excellent flexibility, which is nearly six times the detecting range of bulk piezoelectric substrate based SAW strain sensors. The sensor exhibited a high sensitivity of 193 Hz/ with a maximum hysteresis less than 1.5%. The temperature coefficients of frequency, for Rayleigh and TSM modes, were −85 and −59 ppm/ , respectively. No visible deterioration was observed after cyclic bending for hundreds of times, showing its desirable stability and reliability. By utilizing the dual modes, the strain sensor with a self-temperature calibrated capability can be achieved. The results demonstrate that the sensor is an excellent candidate for strain sensing.
This paper presents a novel flexible capacitive 3D tactile sensor using cross-bar polydimethylsiloxane (PDMS) walls and micropillar arrays as the composite structure dielectric layer. The tactile sensor unit consists of a 2 × 2 capacitor array where electrode pairs are arranged in a cross-bar pattern to ensure a fixed overlap area for these capacitors. A top bump is introduced for the sensor to ensure the force is applied uniformly on the sensor. When a force is applied on the sensor, it changes the capacitances of the four capacitors, distinguishing the forces from different directions. The sensitivities of the sensor in the x-, y- and z-directions are 95.08%/N, 98.30%/N and 237.48%/N, in the ranges of 0-0.15 N, 0-0.15 N and 0-0.1 N respectively, much better than most of reported ones. The high sensitivities of the proposed sensor unit are attributed to the composite structure dielectric layer and the optimized Young’s modulus of PDMS. The flexible capacitive tactile sensor shows great potential for applications in robot technology.
This paper reports a novel flexible film bulk acoustic resonator (FBAR) based on -phase polyvinylidene fluoride (PVDF) piezoelectric polymer. The proposed device was simulated and evaluated; then, a low-temperature photolithography process with a double exposure method was developed to pattern the electrodes for the device, which enabled the device to retain the piezoelectric properties of the -phase PVDF film. Results showed that the β-phase PVDF FBARs had a resonant frequency round 9.212 with a high electromechanical coupling coefficient ( ) of 12.76% ± 0.56%. The device performed well over a wide bending-strain range up to 2400 owing to its excellent flexibility. It showed good stability as a strain sensor with a sensitivity of 80 , and no visible deterioration was observed after cyclic bending tests. The PVDF FBAR also exhibited an exceptionally large temperature coefficient of frequency (TCF) of −4630 , two orders of magnitude larger than those of other FBARs based on common inorganic piezoelectric materials, extraordinarily high sensitivity for temperature sensing. All results showed that -phase PVDF FBARs have the potential to expand the application scope for future flexible electronics.
20 August 2018 in IEEE Transactions on Biomedical Engineering
Objective: Continuous measurement of key physiological parameters, such as heart rate (HR), pulse oxygen saturation (SpO 2 ), and sweat pH value, has very broad applications in healthcare, disease surveillance, and fitness and sports training. In this study, a stretchable optical sensing patch system was developed for real-time continuous noninvasive monitoring of the HR, SpO 2 , and sweat pH, and the sensing data were transmitted to a smartphone through Bluetooth. Methods: The sensor patch system adopted serpentine stretchable interconnects between the optical sensor and microcontroller chip with wireless function on a flexible substrate. The pH sensing function was implemented by coating a pH sensitive organically modified silicate film on the surface of a commercial blood oxygen sensor, achieving simultaneous measurement of HR, SpO 2 , and sweat pH with a single sensor. Results: Real-time on-body assessment was carried out to evaluate the sensor patch system, showing its excellent repeatability and applicability. The sensor patch system could withstand up to 35% extension and exhibited a pH sensitivity of 4.42 mV/pH from 4.0 to 8.0, while the accuracy of HR from 25 to 250 b/min and SpO 2 from 70% to 100% sensing were ±1 b/min and ±2%, respectively. Conclusion: The triple sensing functions was achieved through a single optical sensor on a flexible substrate while holding excellent contact with the body. Significance: The sensor patch system can be used for fitness guidance, skin disease detection, and wound monitoring and management by replacing related sensitive films.
20 December 2018 in Journal of Micromechanics and Microengineering
This work presents the development of flexible dual-mode surface acoustic wave (SAW) sensor based on single crystalline thin film lithium niobate (TF-LN). Numerical modeling is conducted to investigate the SAW propagation and the effects on strain sensitivity. The dependence of strain sensitivity on angles between the applied strain and SAW propagation direction is analyzed numerically and experimentally, showing that the maximum strain sensitivity is at 45° rather than longitudinal direction. 128° Y-cut TF-LN (~50 µ m), obtained by micromachining technique, is utilized as the piezoelectric substrate to fabricate the SAW strain sensors with dual-mode, namely Rayleigh mode and thickness shear mode. The sensor has excellent flexibility and demonstrates remarkable capability for an ultra-wide range strain measurement up to ±3000 . Temperature effects on resonant frequency and strain sensitivity are investigated in the range of 25 °C–100 °C, and similar temperature characteristics are observed for the dual modes. A method of beat frequency between the dual modes is introduced which is able to eliminate the temperature effect on strain sensing, an on-chip temperature influence removing capability. All the results clearly show that this sensor exhibits great potential for applications in flexible electronics and microsystems.
Langasite (LGS) surface acoustic wave (SAW) temperature sensors have a large second order temperature coefficient of frequency, which leads to their non-linear and non-monotonic responses in a wide temperature range and possibly makes the measured temperatures non-unique for a specific sensor response. Here, we propose a high-temperature Pt/LGS SAW sensor with linear frequency–temperature behavior in a wide temperature range, which was fabricated on a LGS (0°, 138.5°, 72°) substrate. The sensor has a single acoustic mode, but dual resonances with similar second- and third-order temperature sensitivities that were utilized for achieving a linear frequency–temperature response by a method of difference. A linear relationship between the measured sensor output (Δfm21) and temperature was obtained in the range of −60 °C to 700 °C, consistent with the theoretical analysis. The sensor has a high sensitivity of −167 ppm/K for the whole temperature range. All the results demonstrated exciting prospects of the sensor for wide temperature monitoring in harsh environments.