Laser ultrasound offers several benefits in comparison to immersion or air-coupled ultrasound: it directly generates stress on the sample surface; it has a wide bandwidth and a small acoustic source can be produced. Conventionally, high-power pulsed lasers are required therefore equipment is bulky and expensive. Here we propose to use mid-power laser diodes, which are small and low cost. To solve the low signal amplitude problem with lower power lasers, the use of spread spectrum signal, arbitrary position, and width binary pulse sets is proposed. To date, a laser driver for this task has not been available. This article describes the development of such a compact driver, where the essential electronics occupy an area of $10\,\,\times20$ mm. The whole system with a fixture for kinematic mount is comparable in size to a conventional piezoelectric ultrasonic transducer. The driver can supply pulse sets of up to 40 A. Individual pulse duration can vary between 20 and 1000 ns (0.5–25-MHz ultrasound range) and the total pulse train duration is limited by the laser type used. Experiments show that up to 10- $\mu \text{s}$ long pulse sets can be used at 10-A current, without laser degradation. Current waveforms, beam profile, and optical response signals were measured for three rectified topologies. It was concluded that the GaN-based constant current switch topology has the best performance, but a power MOSFET in a source current feedback topology can also be used to generate pulses down to 20 ns. Photoacoustic response signals from chirp and phase shift keying modulation have been demonstrated.
6 February 2017 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Bicycle riders are among the highest risk group in traffic. A cyclist simulation study captured kinematics and injuries to legs, pelvis, neck, and head for one human body size. We analyzed the number of parameters (forces acting on left and right tibia, head injury criterion, neck tensile force, neck shear force, and pelvic acceleration) for each of the four different cases: bicyclist ride out—residential driveway, motorist overtaking—undetected bicyclist, bicyclist left turn—same direction, and bicyclist right turn—opposite direction. The comparison of simulation outcomes for leg injuries with official hospital records has shown a very good correlation in terms of injury severity prediction. This study concludes that if countermeasures to prevent fatal cyclist injury in car impacts were to be concentrated on mitigating head and neck impact to the windscreen of the car, a dominant share of fatal cyclist crashes and severe traumatic head injury cases at collision speeds exceeding 40 km/h could be prevented.
In the paper, the reliability of a spatial tubular structure of a bus safety frame formed of different steel profiles is discussed. A methodology for the bus safety structure modeling is presented herein by applying numerical methods that enable us to simulate virtually a test for assessing bus rollover crashworthiness according to the United Nations Economic Commission for Europe (UNECE) Regulation No. 66, and also to assess and ensure the reliability and safety of the structure under operating conditions. The simulation has been performed by applying the mixed method of kinematical analysis and finite elements. In the course of the calculations, physical and geometrical non-linearity of materials was assessed. In addition, an experimental rollover test according to UNECE Regulation No. 66 was performed in this work, striving to verify the provided methodology for modeling by applying numerical methods. For the experiment, an identical safety structure and a rollover stand (identical to the one used in modeling) were used. The rollover test was shot by a Phantom v711 high-speed camera. In the paper, the results of kinematical and dynamic analysis from applying the finite element method and the ones of the experimental test, as well as their comparisons, are provided. It is assessed whether the developed safety structure model is reliable and suitable for use.
4 November 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.5-mm-diameter sensitive element ultrasonic microphone. FE has an acoustic impedance much closer to that of air compared with other alternatives and is low cost and easy to process. The performance of the microphone was evaluated by measuring the sensitivity area map, directivity, ac response, and calibrating the absolute sensitivity. Another novel contribution here is that the sensitivity map was obtained by scanning the focused beam of a laser diode over the microphone surface, producing thermoelastic ultrasound excitation. The electroacoustic response of the microphone served as a sensitivity indicator at a scan spot. Micrometer scale granularity of the FE sensitivity was revealed in the sensitivity map images. It was also demonstrated that the relative ac response of the microphone can be obtained using pulsed laser beam thermoelastic excitation of the whole microphone surface with a laser diode. The absolute sensitivity calibration was done using the hybrid three-transducer reciprocity technique. A large aperture, air coupled transducer beam was focused onto the microphone surface, using the parabolic off-axis mirror. This measurement validated the laser ac response measurements. The FE microphone performance was compared with biaxially stretched polyvinylidene difluoride (PVDF) microphone of the same construction.
In the case of otosclerosis, it has been noticed that even though there are a variety of different prostheses on the market, due to the anatomical characteristics, it is not always possible to restore excellent mobility to the ossicles and the prosthesis. On the one hand, this happens because the incus long process and the prosthesis create difficult angles. On the other hand, incus necrosis is among the most common causes of the loss of stability to the prosthesis and stapedectomy failure. The aim of this research is to suggest an improvement for stapes prosthesis stability and numerically evaluate the impact of the prosthesis constraining to its dynamical behavior. Numerical 3D models of a standard as well as a modified (adjustable angled) stapes prosthesis were created in order to achieve this aim. Consequently, the modal analysis has been performed to evaluate the mechanical behavior of the prosthesis, assuming that the piston (thick part) would be made of Teflon, and the thin part, fixated on the incus long process, would be made from titanium alloy. Finally, the numerical analysis has been conducted by changing the boundary conditions in respect of the prosthesis constraining, where the attached stapes prosthesis connects to the ossicular chain. Subsequently, there were two hypotheses raised for the prosthesis loop constraining. The first is that during the surgery, the prosthesis is perfectly crimped with certain looseness. The second is that the prosthesis is outgrown by the tissues over time and thus becomes over-constrained. Then, the analyzed standard stapes prosthesis does not fulfil its functions because of the over-constraining that develops over time. An improvement for the standard stapes prosthesis, i.e., a modified stapes prosthesis (adjustable angled), that has been proposed in this research allows avoidance of the negative effects of the over-constrained standard stapes prosthesis that appear over time. Moreover, the proposed modified prosthesis helps to regain hearing when the angle between the incus long process and prosthesis is unfavorable.