Andrius Chaziachmetovas

Dr. Andrius Chaziachmetovas

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Linas SvilainisLinas Svilainis
Linas Svilainis
ACAndrius Chaziachmetovas
Andrius Chaziachmetovas
Valdas EidukynasValdas Eidukynas
Valdas Eidukynas
AAArturas Aleksandrovas
Arturas Aleksandrovas
MVMarijus Varatinskas
Marijus Varatinskas
Laser ultrasound offers several benefits in comparison to immersion or air-coupled ultrasound: it directly generates stress on the sample surface; it has a wide bandwidth and a small acoustic source can be produced. Conventionally, high-power pulsed lasers are required therefore equipment is bulky and expensive. Here we propose to use mid-power laser diodes, which are small and low cost. To solve the low signal amplitude problem with lower power lasers, the use of spread spectrum signal, arbitrary position, and width binary pulse sets is proposed. To date, a laser driver for this task has not been available. This article describes the development of such a compact driver, where the essential electronics occupy an area of $10\,\,\times20$ mm. The whole system with a fixture for kinematic mount is comparable in size to a conventional piezoelectric ultrasonic transducer. The driver can supply pulse sets of up to 40 A. Individual pulse duration can vary between 20 and 1000 ns (0.5–25-MHz ultrasound range) and the total pulse train duration is limited by the laser type used. Experiments show that up to 10- $\mu \text{s}$ long pulse sets can be used at 10-A current, without laser degradation. Current waveforms, beam profile, and optical response signals were measured for three rectified topologies. It was concluded that the GaN-based constant current switch topology has the best performance, but a power MOSFET in a source current feedback topology can also be used to generate pulses down to 20 ns. Photoacoustic response signals from chirp and phase shift keying modulation have been demonstrated.

16 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Linas SvilainisLinas Svilainis
Linas Svilainis
ACAndrius Chaziachmetovas
Andrius Chaziachmetovas
DKDarius Kybartas
Darius Kybartas
TATomas Gomez Alvarez-Arenas
Tomas Gomez Alvarez-Arenas
Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method.

4 November 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Linas SvilainisLinas Svilainis
Linas Svilainis
ACAndrius Chaziachmetovas
Andrius Chaziachmetovas
Valdas EidukynasValdas Eidukynas
Valdas Eidukynas
TATomas Gomez Alvarez-Arenas
Tomas Gomez Alvarez-Arenas
Steve DixonSteve Dixon
Steve Dixon
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.5-mm-diameter sensitive element ultrasonic microphone. FE has an acoustic impedance much closer to that of air compared with other alternatives and is low cost and easy to process. The performance of the microphone was evaluated by measuring the sensitivity area map, directivity, ac response, and calibrating the absolute sensitivity. Another novel contribution here is that the sensitivity map was obtained by scanning the focused beam of a laser diode over the microphone surface, producing thermoelastic ultrasound excitation. The electroacoustic response of the microphone served as a sensitivity indicator at a scan spot. Micrometer scale granularity of the FE sensitivity was revealed in the sensitivity map images. It was also demonstrated that the relative ac response of the microphone can be obtained using pulsed laser beam thermoelastic excitation of the whole microphone surface with a laser diode. The absolute sensitivity calibration was done using the hybrid three-transducer reciprocity technique. A large aperture, air coupled transducer beam was focused onto the microphone surface, using the parabolic off-axis mirror. This measurement validated the laser ac response measurements. The FE microphone performance was compared with biaxially stretched polyvinylidene difluoride (PVDF) microphone of the same construction.

30 December 2021 in IEEE Access
Verified
Journal Article
Open access
ARAlberto Rodríguez
Alberto Rodríguez
Linas SvilainisLinas Svilainis
Linas Svilainis
MLMiguel Ángel de la Casa Lillo
Miguel Ángel de la Casa Lillo
TATomas Gomez Alvarez-Arenas
Tomas Gomez Alvarez-Arenas
AAA. Aleksandrovas
A. Aleksandrovas
ASA. Salazar
A. Salazar
This work presents in detail a new method for the optimization of rectangular spread spectrum excitation signals for its use in simple and low-cost ultrasonic pulsers, but that could be extended to other applications based on spread spectrum signals. Starting from rectangular linear frequency modulated (RLFM) chirps, it uses the transfer function of the transmitted signal and received echoes from reference specimens to iterate through a recursive algorithm to obtain arbitrary position and width pulse (APWP) signals with the desired bandwidth, maximizing the energy and the flatness of the spectrum, and enhancing the resolution and dynamic range of conventional chirp excitation signals. This optimization procedure can be repeated for any transducer and material, so that it achieves the best performance in each experimental environment. Such characteristics are ideal for Time-of-Flight estimation, imaging, and applications in which spectral regularity is needed, such as the Split Spectrum Processing (SSP) algorithm, which is used as example to test the performance of the proposed excitation signals. It also allows to specify and change the bandwidth reducing the need to change the transducers. The method is tested with different transducers (2 and 5 MHz focused transducers) and complex composite materials (aluminum-carbon aviation composite and high porosity GFRP composite) in immersion setup for imaging applications using SSP algorithm.

11 May 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MMMartynas Maciulevičius
Martynas Maciulevičius
RRRenaldas Raisutis
Renaldas Raisutis
BJBaltramiejus Jakštys
Baltramiejus Jakštys
Linas SvilainisLinas Svilainis
Linas Svilainis
ACAndrius Chaziachmetovas
Andrius Chaziachmetovas
Saulius SatkauskasSaulius Satkauskas
Saulius Satkauskas
Microbubble (MB)- and ultrasound (US)-facilitated intracellular Ca2+ delivery, known as sonoporation (SP), is a promising anticancer treatment modality, since it allows a spatio-temporally controllable and side-effect-free alternative to conventional chemotherapy. The current study provides extensive evidence that a 5 mM concentration of Ca2+ in combination with US alone or US and Sonovue MBs can be an alternative to the conventional 20 nM concentration of the anticancer drug bleomycin (BLM). Ca2+ application together with SP induces a similar level of death in Chinese hamster ovary cells to the combination of BLM and SP but does not cause systemic toxicity, as is inherent to conventional anticancer drugs. In addition, Ca2+ delivery via SP alters three vital characteristics essential for viable cells: membrane permeability, metabolic activity and proliferation ability. Most importantly, Ca2+ delivery via SP elicits sudden cell death—occurring within 15 min—which remains similar during 24–72 h and 6 d periods. The extensive study of US waves side-scattered by MBs led to the quantification of the cavitation dose (CD) separately for subharmonics, ultraharmonics, harmonics and broadband noise (up to 4 MHz). The CD was suitable for the prognostication of the cytotoxic efficiency of both anticancer agents, Ca2+ and BLM, as was indicated by an overall high (R2 ≥ 0.8) correlation (22 pairs in total). These extensive analytical data imply that a broad range of frequencies are applicable for the feedback-loop control of the process of US-mediated Ca2+ or BLM delivery, successively leading to the eventual standardization of the protocols for the sonotransfer of anticancer agents as well as the establishment of a universal cavitation dosimetry model.

15 July 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Linas SvilainisLinas Svilainis
Linas Svilainis
Jorge CamachoJorge Camacho
Jorge Camacho
DKDarius Kybartas
Darius Kybartas
ACAndrius Chaziachmetovas
Andrius Chaziachmetovas
Valdas EidukynasValdas Eidukynas
Valdas Eidukynas
Spatial distribution of a transduction efficiency over the air-coupled probe surface was proposed as a convenient tool for the probe integrity inspection. In this research, a parabolic reflector is used for passive focusing of the acoustic wave on the surface of inspected probe. Therefore, no additional transducer is required for inspection: probe is used for self-inspection. This approach allows to avoid the expensive focused transducer and replaces it by same type air coupled transducers as probe under test. Moreover, use of the parabolic mirror for focusing is frequency-independent, therefore such approach allows to inspect a wide range of the probes. Spread spectrum signals were used for excitation to improve the SNR and bandwidth coverage. Results of the experimental measurements of air-coupled transducer sensitivity map with natural and artificial defects implemented have been presented. Comparison with previously proposed techniques is given. It was found that defects presence distorts the focused beam, creating large sidelobes. Therefore sensitivity map obtained with proposed technique is lower quality than with previously proposed techniques. Beam profile measurements using a miniature microphone have been presented. Aperture-limiting mask has been proposed to reduce the sidelobes arising due to defects presence and resulting measurements quality has been improved.