Chunyu Xiao

Mr. Chunyu Xiao

Huazhong University of Science and Technology, Wuhan, Hubei, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Acta Astronautica
Verified
Journal Article
Closed access
CXChunyu Xiao
Chunyu Xiao
ECEnrico Canuto
Enrico Canuto
WHWei Hong
Wei Hong
ZZZebing Zhou
Zebing Zhou
JLJun Luo
Jun Luo

21 September 2023 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
CWChengrui Wang
Chengrui Wang
YBYanzheng Bai
Yanzheng Bai
MHMing Hu
Ming Hu
DLDuo Li
Duo Li
KLKe Li
Ke Li
ZZZebing Zhou
Zebing Zhou
Capacitive sensing electronics are critical to space gravitational wave detection missions, providing the test mass motion information for the inertial sensor’s non-sensitive axis control and the drag-free control of the satellite. For the TianQin mission, the capacitive sensor requirement is 6.9 × 10 − 7 p F H z − 1 / 2 at 6 mHz, corresponding to a displacement noise of 1.7 n m H z − 1 / 2 . This paper presents the system design scheme, noise analysis, and performance testing of the capacitive sensor for the TianQin mission. Based on the previous work of our group, a capacitive sensing scheme based on a transformer bridge and modulation–demodulation is adopted. A transformer with a better high LQ product is fabricated, and the preamplifier current noise is reduced to further improve the performance above mHz. The amplitude stability of the AC carrier and the performance of the lock-in amplifier circuit are further improved to reduce the low-frequency 1 / f noise at m H z and below. Finally, a capacitive sensor prototype is developed and tested, the experimental results show that the capacitance measurement noise is better than 3 × 10 − 7 p F H z − 1 / 2 above 1 mHz and better than 6 × 10 − 7 p F H z − 1 / 2 at about 0.1 mHz , which meets the overall performance requirement of the TianQin mission.

5 July 2022 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
CXChunyu Xiao
Chunyu Xiao
YBYanzheng Bai
Yanzheng Bai
HLHongyin Li
Hongyin Li
LLLi Liu
Li Liu
YLYanchong Liu
Yanchong Liu
ZZZebing Zhou
Zebing Zhou
Drag-free control (DFC) is one of the key technologies for space-borne gravitational wave detectors. For the TianQin (TQ) project, non-gravitational disturbances on the spacecraft must be suppressed by DFC. TianQin-1 (TQ-1) is the first satellite for technology verification, whose main goal is to verify the disturbances reduction technologies. In this paper, the DFC requirement and preliminary analysis for the TQ project are introduced, and then the design and the experimental validation with the TQ-1 satellite is presented. In-orbit results show a successful validation of DFC and the residual acceleration of TQ-1 satellite has been suppressed to 5 × 1 0 − 11 m s − 2 H z − 1 / 2 at 10 mHz versus 2 × 1 0 − 9 m s − 2 H z − 1 / 2 thruster noise.

12 May 2022 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
AZAn-Nan Zhou
An-Nan Zhou
LCLin Cai
Lin Cai
CXChunyu Xiao
Chunyu Xiao
DTDing-Yin Tan
Ding-Yin Tan
HLHong-Yin Li
Hong-Yin Li
JLJun Luo
Jun Luo
Non-gravitational force models are critical not only for the applications of satellite orbit determination and prediction, but also for the studies of gravitational reference sensors in space-based gravitational wave detection missions and accelerometers in gravity satellite missions. In this paper, based on the inertial sensor data from the TianQin-1 (TQ-1) mission, a correction has been made in the non-gravitational force models by applying additional terms related to the orbital periods. After taking into account this correction, about 37 hours of TQ-1 inertial sensor data is calibrated in the sensitive axes, i.e. y- and z-axes, by comparing with the simulated non-gravitational accelerations. It is indicated that the peak-to-peak value of the non-gravitational acceleration correction terms are about 2% and 13% of the measured accelerations in the y- and z-axes, respectively. Within the frequency band below 0.01 Hz, the root mean square of calibration residual errors in y- and z-axes are suppressed from 1.03 × 10−9 and 3.872 × 10−9 m s−2 to 8.14 × 10−10 and 1.343 × 10−9 m s−2, respectively. The bias and scale factor of the inertial sensor are also obtained from the calibration by the method of least-squares fit. Meanwhile, the inertial sensor measurements are validated and their signal compositions are analyzed.

8 January 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHonggang Li
Honggang Li
GLGuilin Li
Guilin Li
WHWei Hong
Wei Hong
BCBingxue Chen
Bingxue Chen
LCLiangyu Chu
Liangyu Chu
ZZZebing Zhou
Zebing Zhou
High-energy particles in space will inevitably penetrate the spacecraft into the suspended test mass, which would seriously affect the detection of gravitational waves; therefore, charge measurement and control are essential. Based on the working principle of space inertial sensors, this article proposes a new charge measurement scheme based on capacitive sensing in nonsensitive axes for simultaneous charge measurement during the detection of gravitational waves. According to the dynamic model and actual parameters, the resolution of the proposed method is evaluated as about $6.60\times 10^{-17}$ C in space, which can meet the detection requirement. Further, a torsion pendulum device was set up on ground to carry out charge measurement experiments and verify the evaluation method. The experimental results show that the optimal resolution with the capacitive sensing is about $1.65\times 10^{-14}$ C at 1 mHz, which agrees with the theoretical evaluation. This work demonstrates the feasibility of the capacitive sensing-based charge measurement, which will be a potential scheme in the detection of gravitational waves.

29 August 2023 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
AZAn-Nan Zhou
An-Nan Zhou
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
MHMing Hu
Ming Hu
HLHong-Yin Li
Hong-Yin Li
ZZZebing Zhou
Zebing Zhou
High-precision electrostatic accelerometer has been widely employed in gravity measurement satellites. Accelerometer can be designed for different resolutions and measurement ranges to adapt to different scientific missions. This paper presents an ultra-high sensitivity 70 g-TM electrostatic accelerometer, designed to achieve an adjustable resolution from 10 − 12 m s − 2 Hz − 1 / 2 to 10 − 10 m s − 2 Hz − 1 / 2 with an optimal resolution of 3.3 × 10 − 12 m s − 2 Hz − 1 / 2 . The in-orbit performance of the 70 g-TM accelerometer was tested on the Tianqin-1 satellite.