Izdihar Kamal

Ms. Izdihar Kamal

KPJ Healthcare University College
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IKIzdihar Kamal
Izdihar Kamal
HRHAIRIL RASHMIZAL ABDUL RAZAK
HAIRIL RASHMIZAL ABDUL RAZAK
NSNurzulaikha Supion
Nurzulaikha Supion
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
NHNurul Huda
Nurul Huda
Norkhairunnisa MazlanNorkhairunnisa Mazlan
Norkhairunnisa Mazlan
This study aimed to introduce an alternative, inexpensive, and straightforward polymer with specific mechanical and dielectric properties suitable for the fabrication of a clinical-grade kidney phantom. Two polymer-based phantom materials, polydimethylsiloxane (PDMS) and silicone elastomer (SE), were investigated for their capability to meet the requirements. The concentration ratios of base to curing agent (B/C) were 9.5/1.5, 19/3, 10/1, 20/2, 10.5/0.5, and 21/1 for PDMS and 4.5/5.5, 10/12, 5/5, 11/11, 5.5/4.5, and 12/10 for SE. All samples were mixed, degassed, and poured into Petri dishes and small beakers. The polymer was cured under room temperature for 2 h and then demolded from the hard mold. The air bubbles produced were removed using a vacuum desiccator for 30 min. All samples underwent mechanical testing (tensile strength and elastic modulus), and their dielectric properties were measured using a dielectric probe kit equipped with 85071E materials measurement software. The radiation attenuation properties were also measured using PhyX-Zetra for PDMS phantoms with the chemical formula C2H6OSi. Small changes in base and cross-linker play an essential role in modifying the elastic modulus and tensile strength. The effective atomic number of PDMS showed a similar pattern with human kidney tissue at the intermediate energy level of 1.50 × 10−1 to 1 MeV. Therefore, PDMS can potentially be used to mimic the human kidney in terms of tensile strength, flexibility, the acceptable real part of the complex dielectric constant ε′r, and conductivity, which allows it to be used as a stable kidney phantom for medical imaging purposes.

28 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
IKIzdihar Kamal
Izdihar Kamal
HRHAIRIL RASHMIZAL ABDUL RAZAK
HAIRIL RASHMIZAL ABDUL RAZAK
Muhammad Khalis Abdul KarimMuhammad Khalis Abdul Karim
Muhammad Khalis Abdul Karim
SMSyamsiah Mashohor
Syamsiah Mashohor
JLJosephine Ying Chyi Liew
Josephine Ying Chyi Liew
NRNur Athirah Syima Mohd Rafi
Nur Athirah Syima Mohd Rafi
Medical imaging phantoms are considered critical in mimicking the properties of human tissue for calibration, training, surgical planning, and simulation purposes. Hence, the stability and accuracy of the imaging phantom play a significant role in diagnostic imaging. This study aimed to evaluate the influence of hydrogen silicone (HS) and water (H2O) on the compression strength, radiation attenuation properties, and computed tomography (CT) number of the blended Polydimethylsiloxane (PDMS) samples, and to verify the best material to simulate kidney tissue. Four samples with different compositions were studied, including samples S1, S2, S3, and S4, which consisted of PDMS 100%, HS/PDMS 20:80, H2O/PDMS 20:80, and HS/H2O/PDMS 20:40:40, respectively. The stability of the samples was assessed using compression testing, and the attenuation properties of sample S2 were evaluated. The effective atomic number of S2 showed a similar pattern to the human kidney tissue at 1.50 × 10−1 to 1 MeV. With the use of a 120 kVp X-ray beam, the CT number quantified for S2, as well measured 40 HU, and had the highest contrast-to-noise ratio (CNR) value. Therefore, the S2 sample formulation exhibited the potential to mimic the human kidney, as it has a similar dynamic and is higher in terms of stability as a medical phantom.

7 March 2019 in Asian Pacific Journal of Cancer Care
Verified
Journal Article
Open access
PDF file
NMNur Anis Izzati Che Mut
Nur Anis Izzati Che Mut
NBNoor Hidayah Abu Bakar
Noor Hidayah Abu Bakar
IKIzdihar Kamal
Izdihar Kamal
SSSiti Aisyah Abdullah Suhaimi
Siti Aisyah Abdullah Suhaimi
NMNurul Mawaddah Mohammad
Nurul Mawaddah Mohammad
NZNorhayati Mohd Zain
Norhayati Mohd Zain
Objective: Breast Self-Examination (BSE) is an early detection method of breast cancer. It is able to develop responsibility for breast health among women to always aware of any changes in the breast. Thus, secondary school girls age is the perfect age to start practice the BSE. The purpose of this study is to determine the level of knowledge and awareness on BSE among secondary school girls in Seremban, Negeri Sembilan. Methods: A cross-sectional study was conducted among 502 secondary school girls using self-administered questionnaire covering socio-demographic data, knowledge and awareness of breast cancer and knowledge and awareness of BSE. Results: The mean age of the participants is 14.9 ± 0.06 years. The majority of the participants were Malays (86.5%). A total of 6.1% of the participants had a family history of breast cancer. Nine percent of participants had a good knowledge and 91.0% had poor knowledge regarding BSE. There is a significant difference between the age of participants with the level of knowledge and awareness (p = 0.014). Conclusion: The knowledge and awareness of BSE were poor among secondary school girls in Seremban, Negeri Sembilan.

22 April 2015
Verified
Journal Article
Closed access
IKIzdihar Kamal
Izdihar Kamal
KKKumari Chelliah Kanaga
Kumari Chelliah Kanaga
VKVijayalakshimi Krishnapillai
Vijayalakshimi Krishnapillai
TSTamanang Sulaiman
Tamanang Sulaiman

28 May 2015 in Sultan Qaboos University Medical Journal
Verified
Journal Article
Open access
PDF file
IKIzdihar Kamal
Izdihar Kamal
KCKanaga K. Chelliah
Kanaga K. Chelliah
NMNawal Mustafa
Nawal Mustafa
Objectives: The aim of this research was to examine the average glandular dose (AGD) of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50) and 20% glandular and 80% adipose tissue (20/80) commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA) with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy) for two dimension (2D) and 2.48 mGy for three dimensional (3D) images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.