8 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
GPGennadiy Pivnyak
Gennadiy Pivnyak
YSYuri Stepanenko
Yuri Stepanenko
Kinga StecułaKinga Stecuła
Kinga Stecuła
MKMaryna Kyrychenko
Maryna Kyrychenko
OLOleksandra Lysenko
Oleksandra Lysenko
Roman DychkovskyiRoman Dychkovskyi
Roman Dychkovskyi
This study examines the behavior and control of zero-sequence parameters in IT-type electrical networks under conditions of capacitive insulation asymmetry and complex asymmetric faults on the power receiver side. Existing methods of zero-sequence analysis typically address either symmetrical network conditions or single-phase earth faults in isolation, and they often neglect the combined effects of conductor breakage, transient fault resistance, and capacitive unbalance. To overcome these limitations, this work develops an analytical model based on the general theory of electrical engineering and symmetrical components, enabling a unified description of zero-sequence voltages and currents that incorporates both insulation asymmetry and compound fault scenarios. The model establishes closed-form relationships linking zero-sequence quantities to network parameters, power receiver characteristics, and transient resistances at the fault point. The results demonstrate several previously unreported effects, including a 180° vector shift and nearly 50% reduction in zero-sequence voltage and current magnitudes during simultaneous conductor breakage and earth faults compared with conventional single-phase faults—phenomena that critically influence the correct setting of protection devices. The study further shows that capacitive insulation asymmetry alone may generate zero-sequence voltages sufficient to trigger earth-fault protection regardless of the neutral grounding mode. These findings reveal increased risks of fault escalation, misoperation of existing protection systems, and prolonged unsafe touch voltages. Overall, the derived dependencies provide a new analytical basis for improving the design and coordination of protection systems in IT-type networks.

1 November 2017 in Advanced Engineering Forum
Verified
Journal Article
Closed access
PDF file
RARuslan Agaiev
Ruslan Agaiev
VVVasyl Vlasenko
Vasyl Vlasenko
KDKateryna Dudlia
Kateryna Dudlia
MKMaryna Kyrychenko
Maryna Kyrychenko
DPDmytro Prytula
Dmytro Prytula
In this article the possibility of methane gas extraction in coal deposits exploitation is considered. Experimental data on the application of hydrodynamic impact on a gas-saturated outburst coal seam prior to its baring in order to reduce gasdynamic activity due to an intensification of methane emission are presented. Also a structural and technological scheme of degassing pipelines that includes emergency protection and monitoring of coal mine methane parameters in real-time mode to ensure a safe, trouble-free process of its transportation to the cogeneration plant for further utilization is proposed.

28 February 2023 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
ILI Lutsenko
I Lutsenko
NRN Rukhlova
N Rukhlova
MKMaryna Kyrychenko
Maryna Kyrychenko
RTR Tsyhan
R Tsyhan
VPV Panchenko
V Panchenko
Purpose. Establishing the regularities of changes in influence of power quality indicators caused by the operating modes of photovoltaic (PV) station inverters on the operating modes of distribution networks’ equipment to improve their energy efficiency by reducing power losses. Methodology. To solve the scientific problems, the following methods are used such as: the method of harmonic analysis (Fourier integral); decomposition of the current spectrum by amplitude-frequency component using Mdaq-14 hardware and software platforms and LabVIEW software; the method of data correlation analysis to determine the higher harmonic current dependence on the load of an on-grid inverter; mathematical and physical modeling in the development of a way to improve the energy efficiency of on-grid inverters of PV stations. Findings. The conducted studies on electromagnetic compatibility indicators of grid photovoltaic station inverters in stationary and dynamic operation modes made it possible to establish the characteristic regularities of changes in the spectrum and amplitudes of higher harmonic components depending on the level of inverter loading. Hyperbolic dependences of the change in the sinusoidal signal distortion coefficients of the harmonic component on the level of inverter loading were experimentally established. A method has been developed for reducing the electromagnetic interference levels caused by photovoltaic station converters by implementing a circuit solution and algorithm for loading on-grid inverters in non-stationary modes in order to improve their electromagnetic compatibility and increase the energy efficiency of distribution networks with appropriate decentralized sources. Originality. The regularities are established of influence of the operating mode’s parameters of photovoltaic station inverters on the indicators of electromagnetic compatibility in their power supply system, including taking into account special circuit solutions, which allows increasing the energy efficiency of distribution network modes. Practical value. The method for reducing the electromagnetic interference levels generated by photovoltaic station inverters by implementing the proposed circuit solution and algorithm for loading the on-grid inverters in non-stationary modes is universal and can be applied to any photovoltaic station. This will help to reduce the power losses and electromagnetic damage to equipment from the action of higher harmonic components. Granting the established regularities of higher harmonics influence will allow one to take into account the impact of the relevant indicators on the additional insulation heating of power supply system elements and to assess the corresponding electromagnetic damage, to provide recommendations for consideration of the modes in calculating methods and PV equipment selection.

1 January 2024 in Geo-Technical Mechanics
Verified
Journal Article
Closed access
MUM.S. Poliakov Institute of Geotechnical Mechanics of the National Academy of Sciences of Ukraine
M.S. Poliakov Institute of Geotechnical Mechanics of the National Academy of Sciences of Ukraine
VZVasyl Zberovskyi
Vasyl Zberovskyi
VVVasyl Vlasenko
Vasyl Vlasenko
OPOleksandr Petukh
Oleksandr Petukh
MKMaryna Kyrychenko
Maryna Kyrychenko
Arkadiusz KustraArkadiusz Kustra
Arkadiusz Kustra

1 April 2019 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
OBO.V. Bobrov
O.V. Bobrov
DTD.V. Tsyplenkov
D.V. Tsyplenkov
AGA.M. Grebeniuk
A.M. Grebeniuk
MKMaryna Kyrychenko
Maryna Kyrychenko
Justification of the optimum operation of electromechanical system for production and distribution of pressurized air

12 March 2016 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
VPV. I. Panchenko
V. I. Panchenko
DTD. V. Tsyplenkov
D. V. Tsyplenkov
AGA. M. Grebeniuk
A. M. Grebeniuk
MKMaryna Kyrychenko
Maryna Kyrychenko
OBO. V. Bobrov
O. V. Bobrov
МАШИННО-ТРАНСФОРМАТОРНИЙ АГРЕГАТ ДЛЯ ВІТРОЕНЕРГЕТИЧНИХ УСТАНОВОК