Oleksandra Lysenko

Dr. Oleksandra Lysenko

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
YPYu.A Papaika
Yu.A Papaika
OLOleksandra Lysenko
Oleksandra Lysenko
YKYe.V Koshelenko
Ye.V Koshelenko
IOI.H Olishevskyi
I.H Olishevskyi
New+Power Supply Technologies +https://doi.org/10.33271/nvngu/2021-2 +/jdownloads/pdf/2021/2/02_2021_Contents-en-GB.pdf

8 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
GPGennadiy Pivnyak
Gennadiy Pivnyak
YSYuri Stepanenko
Yuri Stepanenko
Kinga StecułaKinga Stecuła
Kinga Stecuła
MKMaryna Kyrychenko
Maryna Kyrychenko
OLOleksandra Lysenko
Oleksandra Lysenko
Roman DychkovskyiRoman Dychkovskyi
Roman Dychkovskyi
This study examines the behavior and control of zero-sequence parameters in IT-type electrical networks under conditions of capacitive insulation asymmetry and complex asymmetric faults on the power receiver side. Existing methods of zero-sequence analysis typically address either symmetrical network conditions or single-phase earth faults in isolation, and they often neglect the combined effects of conductor breakage, transient fault resistance, and capacitive unbalance. To overcome these limitations, this work develops an analytical model based on the general theory of electrical engineering and symmetrical components, enabling a unified description of zero-sequence voltages and currents that incorporates both insulation asymmetry and compound fault scenarios. The model establishes closed-form relationships linking zero-sequence quantities to network parameters, power receiver characteristics, and transient resistances at the fault point. The results demonstrate several previously unreported effects, including a 180° vector shift and nearly 50% reduction in zero-sequence voltage and current magnitudes during simultaneous conductor breakage and earth faults compared with conventional single-phase faults—phenomena that critically influence the correct setting of protection devices. The study further shows that capacitive insulation asymmetry alone may generate zero-sequence voltages sufficient to trigger earth-fault protection regardless of the neutral grounding mode. These findings reveal increased risks of fault escalation, misoperation of existing protection systems, and prolonged unsafe touch voltages. Overall, the derived dependencies provide a new analytical basis for improving the design and coordination of protection systems in IT-type networks.

1 November 2018
Verified
Conference Paper
Closed access
GKGrzegorz Kosobudzki
Grzegorz Kosobudzki
MRMyhajlo Rogoza
Myhajlo Rogoza
OLOleksandra Lysenko
Oleksandra Lysenko
YPYurii Papaika
Yurii Papaika
Dependences of the level of receiving circuit current pulsation of a contactless electric locomotive while using direct current pulse-width converter in the circuit to control traction drive upon the parameters of π-shaped filter components and commutation frequency of a converter have been obtained basing upon the use of topological method of directed graphs. The proposed method has made it possible to calculate filter parameters and give certain recommendations as for the converter commutation frequency according to the condition of providing minimum level of current pulsation of the electric locomotive receiving circuit.

31 March 2021 in Electrical Engineering and Power Engineering
Verified
Journal Article
Open access
PDF file
YPYu.A. Papaika
Yu.A. Papaika
OLOleksandra Lysenko
Oleksandra Lysenko
ABA.V. Bublikov
A.V. Bublikov
IOI.G. Olishevskiy
I.G. Olishevskiy
Purpose. Analysis of the problem of energy efficiency and electromagnetic compatibility of powerful energy associations with nonlinear loads and renewable energy sources. Finding promising ways to increase energy efficiency of power supply systems. Methodology. Mathematical modeling of electromagnetic compatibility. Findings. The analysis of the problem of energy efficiency and electromagnetic compatibility of powerful energy associations with nonlinear loads and renewable energy sources allows us to formulate the following provisions that determine the objectives of this study. A promising way to increase the energy efficiency of power supply systems is the introduction of refined methods of analysis and forecasting of electrical modes of industrial enterprises, as well as indicators of voltage quality and reliability of electrical equipment. Originality. Although the problem of electromagnetic compatibility has been the subject of numerous domestic and foreign studies, it should be noted that most of these works consider the processes of generating electromagnetic interference in the electrical network without reference to the technological schedules of electrical equipment. Practical value. One of the electromagnetic effects, which is manifested in the operation of frequency converters, are significant levels of interharmonics and higher harmonics, which are generated in the electrical network and contribute to the growth of electricity losses and reduce the service life of electrical equipment. However, the regularities connecting the parameters of the power system and the modes of powerful industrial converters have not been studied, and the substantiation of the parameters of a rational energy efficient mode of the power supply system, taking into account individual graphs of higher harmonics, has not been carried out until today.

3 May 2024 in Електротехнічні та інформаційні системи
Verified
Journal Article
Open access
PDF file
ЮПЮрій Анатолійович Папаїка
Юрій Анатолійович Папаїка
OLOleksandra Lysenko
Oleksandra Lysenko
ДБДмитро Іванович Буртний
Дмитро Іванович Буртний
У статті проведено аналіз впливу перетоків надлишкової реактивної потужності (РП) на режими роботи підземних електричних мереж вугільних шахт. Розглянуто характерні особливостей графіків електричних навантажень та енергобалансів гірничих підприємств. Досліджено сучасні способи компенсації РП в підземних електричних мережах і наведено основні залежності для оцінки економічної ефективності оптимізації перетоків РП. Метою роботи є обґрунтування необхідності дослідження та вирішення питання оптимізації перетоків РП в системі електропостачання гірничого підприємства. Для розв’язання поставлених завдань було проаналізовано сучасний стан підземних електричних мереж вугільних шахт на предмет завантаження підземних електричних мереж надлишковою РП. На підставі проведеного аналізу обґрунтовано необхідність вирішення питання оптимізації перетоків РП в підземних електричних мережах. Запропоновані в роботі залежності оцінки економічної ефективності оптимізації перетоків РП дають змогу проводити вибір найбільш економічно доцільних точок підключення компенсаційного устаткування РП в шахтній мережі. Проведений аналіз дає змогу розглянути проблему перетоків РП з погляду впливу перетоку надлишкового рівня РП на ефективність режимів роботи електричних мереж і вибір основного обладнання.

17 March 2026 in Science, Technology and Innovation
Verified
Journal Article
Open access
PDF file
YPYurii Papaika
Yurii Papaika
OLOleksandra Lysenko
Oleksandra Lysenko
MMMaksim Malyshko
Maksim Malyshko
The article examines the possibilities of using renewable energy sources for distributed generation in the Ukrainian power system. Potential risks and possible scenarios for the occurrence of resonance phenomena in the circuits of large-scale grid-connected solar power plants are discussed. The results of amplitude–frequency characteristic modeling identify the limiting ranges of resonance frequencies under varying numbers of STATCOM devices and different power supply system parameters. The issue of electromagnetic compatibility between solar inverters and a centralized power system with limited capacity is investigated. The effect of higher-order current harmonic absorption resulting from changes in the power of industrial load nodes is described. Studies of the electromagnetic interactions between solar power plants and industrial loads are essential for the further development of electromagnetic compatibility theory.