Alba Diaz-Martinez

Ms. Alba Diaz-Martinez

Polytechnic University of Valencia, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
RBRaja Beskhani
Raja Beskhani
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
GPGema Prats-Boluda
Gema Prats-Boluda
One of the remaining challenges for the scientific-technical community is predicting preterm births, for which electrohysterography (EHG) has emerged as a highly sensitive prediction technique. Sample and fuzzy entropy have been used to characterize EHG signals, although they require optimizing many internal parameters. Both bubble entropy, which only requires one internal parameter, and dispersion entropy, which can detect any changes in frequency and amplitude, have been proposed to characterize biomedical signals. In this work, we attempted to determine the clinical value of these entropy measures for predicting preterm birth by analyzing their discriminatory capacity as an individual feature and their complementarity to other EHG characteristics by developing six prediction models using obstetrical data, linear and non-linear EHG features, and linear discriminant analysis using a genetic algorithm to select the features. Both dispersion and bubble entropy better discriminated between the preterm and term groups than sample, spectral, and fuzzy entropy. Entropy metrics provided complementary information to linear features, and indeed, the improvement in model performance by including other non-linear features was negligible. The best model performance obtained an F1-score of 90.1 ± 2% for testing the dataset. This model can easily be adapted to real-time applications, thereby contributing to the transferability of the EHG technique to clinical practice.

7 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
GPGema Prats-Boluda
Gema Prats-Boluda
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
VAVicente José Diago Almela
Vicente José Diago Almela
YYYiyao Ye-Lin
Yiyao Ye-Lin
Due to its high sensitivity, electrohysterography (EHG) has emerged as an alternative technique for predicting preterm labor. The main obstacle in designing preterm labor prediction models is the inherent preterm/term imbalance ratio, which can give rise to relatively low performance. Numerous studies obtained promising preterm labor prediction results using the synthetic minority oversampling technique. However, these studies generally overestimate mathematical models’ real generalization capacity by generating synthetic data before splitting the dataset, leaking information between the training and testing partitions and thus reducing the complexity of the classification task. In this work, we analyzed the effect of combining feature selection and resampling methods to overcome the class imbalance problem for predicting preterm labor by EHG. We assessed undersampling, oversampling, and hybrid methods applied to the training and validation dataset during feature selection by genetic algorithm, and analyzed the resampling effect on training data after obtaining the optimized feature subset. The best strategy consisted of undersampling the majority class of the validation dataset to 1:1 during feature selection, without subsequent resampling of the training data, achieving an AUC of 94.5 ± 4.6%, average precision of 84.5 ± 11.7%, maximum F1-score of 79.6 ± 13.8%, and recall of 89.8 ± 12.1%. Our results outperformed the techniques currently used in clinical practice, suggesting the EHG could be used to predict preterm labor in clinics.

5 July 2020 in Entropy
Verified
Journal Article
Open access
PDF file
JMJavier Mas
Javier Mas
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
APAlfredo Perales-Marín
Alfredo Perales-Marín
GPGema Prats-Boluda
Gema Prats-Boluda
Electrohysterography (EHG) has been shown to provide relevant information on uterine activity and could be used for predicting preterm labor and identifying other maternal fetal risks. The extraction of high-quality robust features is a key factor in achieving satisfactory prediction systems from EHG. Temporal, spectral, and non-linear EHG parameters have been computed to characterize EHG signals, sometimes obtaining controversial results, especially for non-linear parameters. The goal of this work was to assess the performance of EHG parameters in identifying those robust enough for uterine electrophysiological characterization. EHG signals were picked up in different obstetric scenarios: antepartum, including women who delivered on term, labor, and post-partum. The results revealed that the 10th and 90th percentiles, for parameters with falling and rising trends as labor approaches, respectively, differentiate between these obstetric scenarios better than median analysis window values. Root-mean-square amplitude, spectral decile 3, and spectral moment ratio showed consistent tendencies for the different obstetric scenarios as well as non-linear parameters: Lempel–Ziv, sample entropy, spectral entropy, and SD1/SD2 when computed in the fast wave high bandwidth. These findings would make it possible to extract high quality and robust EHG features to improve computer-aided assessment tools for pregnancy, labor, and postpartum progress and identify maternal fetal risks.

12 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
GPGema Prats-Boluda
Gema Prats-Boluda
JMJose L. Martinez-de-Juan
Jose L. Martinez-de-Juan
ADAlba Díaz
Alba Díaz
IMIsauro Rogelio Monfort-Ortiz
Isauro Rogelio Monfort-Ortiz
YYYiyao Ye-Lin
Yiyao Ye-Lin
Electrohysterography (EHG) has emerged as an alternative technique to predict preterm labor, which still remains a challenge for the scientific-technical community. Based on EHG parameters, complex classification algorithms involving non-linear transformation of the input features, which clinicians found difficult to interpret, were generally used to predict preterm labor. We proposed to use genetic algorithm to identify the optimum feature subset to predict preterm labor using simple classification algorithms. A total of 203 parameters from 326 multichannel EHG recordings and obstetric data were used as input features. We designed and validated 3 base classifiers based on k-nearest neighbors, linear discriminant analysis and logistic regression, achieving F1-score of 84.63 ± 2.76%, 89.34 ± 3.5% and 86.87 ± 4.53%, respectively, for incoming new data. The results reveal that temporal, spectral and non-linear EHG parameters computed in different bandwidths from multichannel recordings provide complementary information on preterm labor prediction. We also developed an ensemble classifier that not only outperformed base classifiers but also reduced their variability, achieving an F1-score of 92.04 ± 2.97%, which is comparable with those obtained using complex classifiers. Our results suggest the feasibility of developing a preterm labor prediction system with high generalization capacity using simple easy-to-interpret classification algorithms to assist in transferring the EHG technique to clinical practice.

26 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ADAlba Díaz
Alba Díaz
JMJavier Mas
Javier Mas
GPGema Prats-Boluda
Gema Prats-Boluda
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
KCKaren Cardona-Urrego
Karen Cardona-Urrego
YYYiyao Ye-Lin
Yiyao Ye-Lin
Postpartum hemorrhage (PPH) is one of the major causes of maternal mortality and morbidity worldwide, with uterine atony being the most common origin. Currently there are no obstetrical techniques available for monitoring postpartum uterine dynamics, as tocodynamometry is not able to detect weak uterine contractions. In this study, we explored the feasibility of monitoring postpartum uterine activity by non-invasive electrohysterography (EHG), which has been proven to outperform tocodynamometry in detecting uterine contractions during pregnancy. A comparison was made of the temporal, spectral, and non-linear parameters of postpartum EHG characteristics of vaginal deliveries and elective cesareans. In the vaginal delivery group, EHG obtained a significantly higher amplitude and lower kurtosis of the Hilbert envelope, and spectral content was shifted toward higher frequencies than in the cesarean group. In the non-linear parameters, higher values were found for the fractal dimension and lower values for Lempel-Ziv, sample entropy and spectral entropy in vaginal deliveries suggesting that the postpartum EHG signal is extremely non-linear but more regular and predictable than in a cesarean. The results obtained indicate that postpartum EHG recording could be a helpful tool for earlier detection of uterine atony and contribute to better management of prophylactic uterotonic treatment for PPH prevention.

21 February 2021 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
MAMaría de Arriba-García
María de Arriba-García
ADAlba Díaz
Alba Díaz
IMIsauro Rogelio Monfort-Ortiz
Isauro Rogelio Monfort-Ortiz
ARAlba Roca-Prats
Alba Roca-Prats
SMSara Monfort-Beltrán
Sara Monfort-Beltrán
APAlfredo Perales-Marín
Alfredo Perales-Marín
COVID-19 was declared a pandemic and confinement with movement restriction measures were applied in Spain. Postnatal mental disorders are common but frequently undiagnosed, being a risk period to d...