A microwave microfluidic sensor for detecting binary liquid mixtures with a dielectric method at RF/microwave frequencies is presented in this article. The sensor is based on a split-ring resonator (SRR) that is implemented in a microstrip transmission line, with interdigitated electrodes (IDEs) being integrated into the ring for liquid detection. Based on the equivalent circuit of the IDE-SRR device and with a series of finite element simulations, the detection theory is developed, and the device design optimization is investigated. The validation measurements on water-isopropanol liquid mixtures with various concentrations show that the proposed IDE-SRR sensor has higher sensitivity than the previous standard SRR sensor. The IDE-SRR sensor is then used to detect two binary liquids, i.e., water-methanol mixtures and water-tetrahydrofuran mixtures. The measured effective permittivity results of the binary mixtures at RF/microwave frequency range are compared with the existing mixing models for binary dielectric mixtures at zero frequency.
15 July 2021 in IEEE Transactions on Microwave Theory and Techniques
Uncertainty analysis is performed on a coaxial probe-based dielectric spectroscopy measurement platform, and its impact on the modeling of dielectric relaxation in an aqueous solution is further analyzed. Based on the characterization theory and calibration principle of the platform, uncertainty due to the different available expressions and parameters of the calibration liquid is calculated. Then, repeatability uncertainty related to drift of the measurement platform, environment change, position variation of the probe immersed in the liquid under test (LUT), and so on is analyzed. Next, three types of water–alcohol mixtures and one group of glucose solutions are measured using the platform. Based on the measurement results, the best model is chosen to analyze the frequency dependence of the solutions’ relaxation properties. In addition, based on the uncertainty analysis, appropriate mathematical formulas are provided to model the composition dependence of the solutions’ relaxation parameters, which can be used as a liquid detection technique for chemical and biological applications.
1 November 2021 in IEEE Transactions on Microwave Theory and Techniques
A fully automated electrically controlled tunable interference-based microwave sensor is demonstrated with broadband complex permittivity measurements of aqueous solutions within the frequency range of 12–18 GHz. To construct deep destructive interference over the above-mentioned bandwidth, two quadrature hybrids (QHs or 90° coupler) split and combine the signals of material-under-test (MUT) channel and reference liquid (REF) channel with 180° phase shift. Together with voltage variable phase shifters (PSs) and attenuators in both channels, the destructive interference nulls of the desired frequency can be easily tuned having a $Q$ -factor of $2.67\times {10}^{3}$ . A coplanar waveguide (CPW) sensor design was used as the microwave sensing structure and closed microfluidic channel was designed and manufactured with polydimethylsiloxane (PDMS) to facilitate the alteration of MUT, REF, and calibration liquids. Benefiting from electrically controlled PS and attenuator, the measurement system is fully automated for accurate and fast broadband microwave liquid characterization. Measurement of 2-propanol-water solutions (isopropyl alcohol (IPA) solutions) with volume concentration of 1% is performed to illustrate automation processes and its high sensitivity. A mathematical model improved from those in the literature by taking conductor loss and mismatch effects into consideration was applied to extract MUT permittivity, generalizing the calibration procedure with the air and deionized (DI) water as calibration materials, which results in improvements in accuracy, sensitivity, and effective MUT volume. Comparing to state-of-the-art sensors, the proposed setup has an average relative error (ARE) of 1.443% for the effective volume of 5.18 $\mu \text{L}$ . The complex permittivity of 2-propanol-water solutions with different mole fractions were obtained and confirmed with current literature data.
Accurate permittivity characterization has attracted a lot of attention in various areas. Resonant characterization methods are well-known for their accuracy, but they are restricted in very narrow frequency ranges, and thus, they are normally not recommended to be used for dispersive or high-loss materials. Transmission line characterization techniques are outstanding for being inexpensive, accurate, and broadband, but the algorithms are often complex to perform. This paper proposes a fast, simple, and accurate broadband permittivity characterization algorithm, which is mainly suitable for millimeter-wave applications. It combines a general line–line method and a closed-form algorithm, extracting the complex permittivity of the material under test (MUT) without the need for calculating any intermediate parameters. Validation measurements on de-ionized water in the frequency range from 140 to 220 GHz are in very good agreement with the literature data, which successfully indicates that the proposed algorithm is reliable and accurate for millimeter wave permittivity characterization.
A highly sensitive, large throughput and wide dynamic range (in the aspect of size and material type) broadband tunable microwave interferometer based rectangular waveguide wear debris detection system is presented. Passing of (non)ferrous and (non)conductive particles through the sensor, which causes inductance and/or capacitance changes, are detected as transmission signal variations of the system. We first demonstrate the sensing principle with the aluminum particle of $800~\mu \text{m}$ and epoxy resin particle of 1 mm 3 at 6 GHz. Then, the effects of particle size and flow speed are tested with aluminum particles ranging from $200~\mu \text{m}$ to 1.8 mm. The measurement results show that the system is able to measure particle sizes with known material and differentiate nonconductive particles from conductive ones. With the proposed data processing techniques, this system is capable of detecting as small as $76~\mu \text{m}$ particles within an 8 mm outer diameter tube. And with future improvements on sensitivity and particle material characterization, the proposed system has the potential to differentiate (non)ferrous and (non)conductive particles and measure their sizes as a real-time wear debris sensing devices for rotating and reciprocating machines.
Microwave dielectric sensing offers a rapid, label-free, and non-invasive way of characterization and sensing of biological materials at the microfluidic scale. In this work, a dielectric sensing is achieved with a microwave interferometric setup that is applied to cytometric applications. A fast way to analyze and design an interferometric system at microwave frequencies in software tools is proposed together with a novel manufacturing and assembly process, which enables a short recovery time and avoids extensive microwave-microfluidic chip fabrication. The simulation and measurement results of the interferometric setup are in agreement with an excellent match at levels below S21 = −60 dB. The sensitive microwave setup is evaluated on measurements of 3 µm polystyrene spheres and finally applied for characterization of a widely used laboratory Saccharomyces cerevisiae strain, the S288C, in a frequency range from 4 to 18 GHz.