Muhammad Faheem Ud Din Afzal

Dr. Muhammad Faheem Ud Din Afzal

Florida International University, Miami, Florida, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
AHAsif Hameed
Asif Hameed
ARAli Murtaza Rasool
Ali Murtaza Rasool
YIYasser Ibrahim
Yasser Ibrahim
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
AQAsad Ullah Qazi
Asad Ullah Qazi
IHIqra Hameed
Iqra Hameed
Sufficient deformability can be achieved in concrete while maintaining segregation resistance either by using a chemical viscosity-modifying admixture (VMA) or increasing the fine content in the concrete. Using VMA, the initial cost of self-compacting concrete (SCC) increases, making it unsuitable for general construction. As a result, alternative methods for lowering the cost of SCC must be investigated. In this study, we assess the effectiveness of fly ash (FA) as a viscosity-modifying agent in the production of cost-effective and durable SCC. We also forge new pathways for sustainable development. The percentage of FA, superplasticizer dose, and water/binder ratio were varied, whereas the amounts of cement and water, as well as fine/coarse aggregate content were kept constant. Fresh properties, such as flow, filling and passing abilities, viscosity, and segregation resistance, were measured. Compressive/flexural strength, density, water absorption, and rate of water absorption of hardened SCC were also determined. The test results showed that fly ash can be used as an alternative to a VMA to produce cost-effective, self-compacting concrete. The slump flow of the various fresh-state concrete mixes ranged from 200 to 770 mm, with an L-box ratio of 0 to 1 and a flow time of 2.18 to 88 s. At 28 and 56 days, the compressive strengths of the concrete mixes with fly ash were found to be comparable to those of the control concrete mixes with VMA. The cost of ingredients for a specific SCC mix is 26.8% lower than the price of control concrete, according to a cost comparison assessment.

10 May 2023 in Metals
Verified
Journal Article
Open access
PDF file
AHAsif Hameed
Asif Hameed
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
Ali JavedAli Javed
Ali Javed
ARAli Murtaza Rasool
Ali Murtaza Rasool
Mohsin QureshiMohsin Qureshi
Mohsin Qureshi
IAImran Ashraf
Imran Ashraf
Steel reinforcement corrosion in concrete structures such as bridges, industrial plants, marine structures, and coastal buildings is a growing concern due to its impact on cost, safety, and serviceability. Corrosion leads to spalling, cracking, and reduced reinforcement diameter, which can compromise structural integrity. This study examines the behavior of concrete columns with corroded reinforcement in two phases. In the first phase, 72 columns of 150 × 150 mm cross-sectional dimensions and 300 mm length were cast and subjected to an accelerated corrosion technique. The study examined variables such as concrete cover, concrete strength, and corrosion exposure. The second phase involved studying the axial behavior of corroded columns concerning the effect of column length. Column specimens of 150 × 150 mm cross-sectional dimensions and lengths of 500 mm, 700 mm, and 900 mm were cast, corroded, and tested under axial compressive load. The study revealed that a 30 mm concrete cover offers 10% more protection against corrosion than a 20 mm cover. Continuous exposure to a corrosive environment reduces the load-carrying capacity by 50%, while columns with 28 MPa concrete strength can carry 4% more load. Longer columns are more susceptible to corrosion, leading to a significant reduction in load-carrying capacity and concrete cover damage. Therefore, maintaining adequate concrete cover, strength, and regular inspections are essential to address steel reinforcement corrosion and preserve structural integrity.

6 November 2023 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
AJAli Javed
Ali Javed

15 March 2023 in Infrastructures
Verified
Journal Article
Open access
PDF file
Ali JavedAli Javed
Ali Javed
CGChaitanya Krishna Gadagamma
Chaitanya Krishna Gadagamma
KAKhawaja Ali
Khawaja Ali
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
Armin MehrabiArmin Mehrabi
Armin Mehrabi
KMKimiro MEGURO
Kimiro MEGURO
Reinforced concrete (RC) frames are an integral part of modern construction as they resist both gravity and lateral loads in beams and columns. However, the construction methodologies of RC frames are vulnerable to non-engineering defects, particularly in developing countries. The most common non-engineering defect occurs due to improper lap splice, which can compromise the structural integrity. This research demonstrates an easy, low-cost, and verifiable experimental technique incorporating micro-concrete to evaluate the seismic performance of a completely engineered RC frame with the defect of improper lap splice. The micro-concrete was prepared by using the locally available material for a target compressive strength and then two scaled-down RC frames (1/16 scale) were prepared, including one proper frame and another with improper lap splice. Finally, these frames were tested on a shake table to study their behavior under various seismic loading conditions. This study quantifies the severity of high-risk structural systems due to non-engineering defects. The experimental results demonstrate that improper lap splice can alter the frame’s damage points, triggering the failure of the whole structure.

22 February 2024 in Eng
Verified
Journal Article
Open access
PDF file
ARAli Murtaza Rasool
Ali Murtaza Rasool
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
MRMuhammad Usman Rashid
Muhammad Usman Rashid
Structures are recommended to be designed and constructed with the integration of structural health monitoring techniques to ensure that they can dissipate a large amount of energy without considerable damage when subjected to earthquakes. Hysteretic (H), friction (F), viscous (V), and viscoelastic (VE) dampers were employed in this study to observe the response of buildings using the commercially available software ETABS. The effect of different dampers along with configurations on three prototype concrete buildings (3, 5, and 10-storey) was studied by performing a time history analysis. Initially, the response of the buildings was observed in terms of storey drifts, base shear, and displacement without using dampers, while gradually increasing the damping ratio from 0 to 40%. Subsequently, the response of the buildings was evaluated in terms of displacements and base shear using various types of dampers with different configurations. The analysis results demonstrated that the effectiveness of viscous and viscoelastic dampers is higher for 3 and 5-storey buildings, while friction and hysteresis dampers are more suitable for 10-storey buildings. This information enables informed decisions regarding the performance and maintenance of dampers, contributing to the overall resilience and durability of structures in seismic events.

7 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMuhammad Saqlain Awan
Muhammad Saqlain Awan
Ali JavedAli Javed
Ali Javed
Muhammad Faheem Ud Din AfzalMuhammad Faheem Ud Din Afzal
Muhammad Faheem Ud Din Afzal
LVLuis Federico Navarro Vilchez
Luis Federico Navarro Vilchez
Armin MehrabiArmin Mehrabi
Armin Mehrabi
The significance of long-span bridges being susceptible to wind-induced vibrations and the need for evaluating their aerodynamic performance is the focus of this study. The main emphasis is on experimental methods for assessing the bridges’ aerodynamic stability, using sectional model tests with the free vibration technique. The dynamic properties of the model are determined from the measured response, using various system identification methods, including the modified Ibrahim time domain (MITD) and iterative least squares (ILS) for two-degree-of-freedom systems and the logarithmic decrement method (LDM) and the Hilbert transform method (HTM) for single-degree-of-freedom (SDOF) systems. A new dynamic testing setup was designed to facilitate single-degree-of-freedom (heave and pitch) and coupled two-degree-of-freedom (2DOF) motion in a wind tunnel section model. The vertical and torsional stiffnesses of the model were adjusted with elastic springs. A Great Belt Bridge section model was selected for testing due to its streamlined aerodynamic shape. The direct and crossflow derivatives were extracted from the measured response using the system identification methods mentioned. Additionally, analytical studies and numerical computational fluid dynamics simulations were conducted to validate the experimental results. The study found that HTM is most effective in SDOF due to its ability to extract both damping and frequency from the nonlinear response, whereas the MITD method is faster in converging system parameters in 2DOF system tests. The experimental and numerical results are comparable to the flat plate, which confirms the streamlined behavior of the Great Belt section from an aerodynamic perspective.