Maciej Gawlikowski

Dr. Maciej Gawlikowski

Silesian University of Technology, Faculty of Biomedical Engineering
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
MGMaciej Gawlikowski
Maciej Gawlikowski
Miroslawa El FrayMiroslawa El Fray
Miroslawa El Fray
KJKarolina Janiczak
Karolina Janiczak
BZBarbara Katarzyna Zawidlak-Węgrzyńska
Barbara Katarzyna Zawidlak-Węgrzyńska
RKRoman Kustosz
Roman Kustosz
(1) Background: The evaluation of ventricular assist devices requires the usage of biocompatible and chemically stable materials. The commonly used polyurethanes are characterized by versatile properties making them well suited for heart prostheses applications, but simultaneously they show low stability in biological environments. (2) Methods: An innovative material-copolymer of poly(ethylene-terephthalate) and dimer linoleic acid—with controlled and reproducible physico-mechanical and biological properties was developed for medical applications. Biocompatibility (cytotoxicity, surface thrombogenicity, hemolysis, and biodegradation) were evaluated. All results were compared to medical grade polyurethane currently used in the extracorporeal heart prostheses. (3) Results: No cytotoxicity was observed and no significant decrease of cells density as well as no cells growth reduction was noticed. Thrombogenicity analysis showed that the investigated copolymers have the thrombogenicity potential similar to medical grade polyurethane. No hemolysis was observed (the hemolytic index was under 2% according to ASTM 756-00 standard). These new materials revealed excellent chemical stability in simulated body fluid during 180 days aging. (4) Conclusions: The biodegradation analysis showed no changes in chemical structure, molecular weight distribution, good thermal stability, and no changes in surface morphology. Investigated copolymers revealed excellent biocompatibility and great potential as materials for blood contacting devices.

1 October 2017 in Materials Characterization
Verified
Journal Article
Closed access
ASAgnieszka Stróż
Agnieszka Stróż
BŁBożena Łosiewicz
Bożena Łosiewicz
MZMaciej Zubko
Maciej Zubko
BCB. Chmiela
B. Chmiela
KBKatarzyna Balin
Katarzyna Balin
Tomasz GoryczkaTomasz Goryczka
Tomasz Goryczka

16 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
BŁBożena Łosiewicz
Bożena Łosiewicz
ASAgnieszka Stróż
Agnieszka Stróż
POPatrycja Osak
Patrycja Osak
JMJoanna Maszybrocka
Joanna Maszybrocka
AGAnna Gerle
Anna Gerle
SBSylwia Bogunia
Sylwia Bogunia
This work concerns the development of a method of functionalization of the surface of the biomedical Ti–6Al–7Nb alloy by producing oxide nanotubes (ONTs) with drug-eluting properties. Shaping of the morphology, microstructure, and thickness of the oxide layer was carried out by anodization in an aqueous solution of 1 M ethylene glycol with the addition of 0.2 M NH4F in the voltage range 5–100 V for 15–60 min at room temperature. The characterization of the physicochemical properties of the obtained ONTs was performed using SEM, XPS, and EDAX methods. ONTs have been shown to be composed mainly of TiO2, Al2O3, and Nb2O5. Single-walled ONTs with the largest specific surface area of 600 cm2 cm−2 can be obtained by anodization at 50 V for 60 min. The mechanism of ONT formation on the Ti–6Al–7Nb alloy was studied in detail. Gentamicin sulfate loaded into ONTs was studied using FTIR, TG, DTA, and DTG methods. Drug release kinetics was determined by UV–Vis spectrophotometry. The obtained ONTs can be proposed for use in modern implantology as carriers for drugs delivered locally in inflammatory conditions.

1 November 2006 in Journal de Physique IV
Verified
Journal Article
Closed access
PDF file
MGMaciej Gawlikowski
Maciej Gawlikowski
TPT. Pustelny
T. Pustelny
RKR. Kustosz
R. Kustosz

2 November 2020 in Preprints.org
Verified
Preprint
Open access
MGMaciej Gawlikowski
Maciej Gawlikowski
MFMiroslawa El Fray
Miroslawa El Fray
KJKarolina Janiczak
Karolina Janiczak
BZBarbara Zawidlak-Wegrzynska
Barbara Zawidlak-Wegrzynska
RKRoman Kustosz
Roman Kustosz
(1) Background: The evaluation of ventricular assist devices requires the usage of biocompatible and chemically stable materials. The commonly used polyurethanes are characterized by versatile properties making them well suited for heart prostheses applications but simultaneously they show low stability in biological environment. (2) Methods: An innovative material - copolymer of poly(ethylene-terephthalate) and dimer linoleic acid - with controlled and reproducible physico-mechanical and biological properties was developed for medical applications. Biocompatibility (cytotoxicity, surface thrombogenicity, hemolysis and biodegradation) were evaluated. All results were compared to medical grade polyurethane currently used in the extracorporeal heart prostheses. (3) Results: No cytotoxicity was observed and no significant decrease of cells density as well as no cells growth reduction was noticed. Thrombogenicity analysis showed that the investigated copolymers have the thrombogenicity potential similar to medical grade polyurethane. No hemolysis was observed (the hemolytic index was under 2% according to ASTM 756-00 standard). These new materials revealed excellent chemical stability in simulated body fluid during 180 days ageing. (4) Conclusions: The biodegradation analysis showed no changes in chemical structure, molecular weight distribution, good thermal stability and no changes in surface morphology. Investigated copolymers revealed excellent biocompatibility and great potential as materials for blood contacting devices.

Verified
Journal Article
Open access
PDF file
ASAgnieszka Stróż
Agnieszka Stróż
MGMaciej Gawlikowski
Maciej Gawlikowski
KBKatarzyna Balin
Katarzyna Balin
POPatrycja Osak
Patrycja Osak
JKJulian Kubisztal
Julian Kubisztal
BŁBożena Łosiewicz
Bożena Łosiewicz
The success of implant treatment is dependent on the osseointegration of the implant. The main goal of this work was to improve the biofunctionality of the Ti-13Nb-13Zr implant alloy by the production of oxide nanotubes (ONTs) layers for better anchoring in the bone and use as an intelligent carrier in drug delivery systems. Anodization of the Ti-13Nb-13Zr alloy was carried out in 0.5% HF, 1 M (NH4)2SO4 + 2% NH4F, and 1 M ethylene glycol + 4 wt.% NH4F electrolytes. Physicochemical characteristics of ONTs were performed by high-resolution electron microscopy (HREM), X-ray photoelectron spectroscopy (XPS), and scanning Kelvin probe (SKP). Water contact angle studies were conducted using the sitting airdrop method. In vitro biological properties and release kinetics of ibuprofen were investigated. The results of TEM and XPS studies confirmed the formation of the single-walled ONTs of three generations on the bi-phase (α + β) Ti-13Nb-13Zr alloy. The ONTs were composed of oxides of the alloying elements. The proposed surface modification method ensured good hemolytic properties, no cytotoxity for L-929 mouse cells, good adhesion, increased surface wettability, and improved athrombogenic properties of the Ti-13Nb-13Zr alloy. Nanotubular surfaces allowed ibuprofen to be released from the polymer matrix according to the Gallagher–Corrigan model.