Wanyang Wang

Mr. Wanyang Wang

Huazhong University of Science and Technology, Wuhan, Hubei, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WWWanyang Wang
Wanyang Wang
RMRun Min
Run Min
DZdesheng zhang
desheng zhang
HZHuangpeng Zhang
Huangpeng Zhang
QTQiaoling Tong
Qiaoling Tong
XZXuecheng Zou
Xuecheng Zou
In discontinuous conduction mode boost converters, the switching-node voltage oscillates after the inductor current reaches zero, leading to fluctuating power loss. To investigate this, a circulating energy model is first proposed. Accurate power loss is analyzed with consideration of oscillation damping effect, reverse conduction of power switch, and nonlinear capacitance effect. Analysis shows that the loss can be minimized when the switch is turned on at specific switching-node voltage valleys. Therefore, to minimize the power loss, a grouped valley switching (GVS) control is proposed to count the valleys and turn on the switch at the optimal valley. However, dynamic changes in valleys will cause frequency hopping, resulting in degraded total harmonic distortion (THD) in input current. To address this issue, the GVS controller turns on the switch at constant valleys in a half-line cycle, while adaptively calculating the on -time with online tracked oscillation duration. For efficiency improvement, the optimal valleys are grouped and tuned based on a comprehensive power loss analysis. Experimental results validate the effectiveness of the proposed control. Compared with conventional variable on -time controls, the proposed control improves an average efficiency of 0.4% across the entire power range under 110/220 VAC input. The THD is below 3.1% at 250 W rated power.

30 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
XLXinjun Liu
Xinjun Liu
DZDonglai Zhang
Donglai Zhang
WWWanyang Wang
Wanyang Wang
FZFanwu Zhang
Fanwu Zhang
JYJun Yuan
Jun Yuan
NLNingyu Liu
Ningyu Liu
For boost power factor correction (PFC) converters operating in critical conduction mode (CRM), charge compensation strategies are utilized to improve input current distortion. However, since massive calculations are required under complex working conditions, it is difficult to achieve accurate charge compensation with limited real-time computing resources. To solve this issue, this paper proposes an adaptive charge-compensation-based variable on-time (ACVOT) control strategy. The ACVOT controller calculates the required switching on-time by adding a fundamental value and an extended on-time. The fundamental value is adjusted by the loop compensator in each half-line cycle to provide a basic bias. The extended on-time is calculated based on partial charge compensation equation in each switching cycle to reduce the distortion. Compared with conventional digital variable on-time (VOT) control, the proposed strategy improves the input current total harmonics distortion (THD) and reduces the LUT/register resources by 54%/43% in FPGA realization. To verify the effectiveness of the proposed strategy, a 200 W prototype is built using the GaN HEMT transistor, where the THD is reduced to 1.4% at full load.

11 December 2023
Verified
Conference Paper
Closed access
WWWanyang Wang
Wanyang Wang
LZLiving Zhu
Living Zhu
WZWeniia Zhang
Weniia Zhang
BHBaoqiang Huang
Baoqiang Huang
RMRun Min
Run Min
YWYinyu Wang
Yinyu Wang
This article proposes an optimized valley skipping strategy to improve efficiency and reduce total harmonic distortion (THD) for boost power factor correction (PFC) converters in discontinuous conduction mode (DCM). In DCM, the valley skipping strategy is used to reduce the switching ON loss of the power switch. However, conventional skipping strategy causes dynamic changing valleys in a half-line cycle, leading to frequency hopping and extra current distortion. To avoid this, a control strategy based on constant skipping valleys (CSV) is proposed. Firstly, the switching frequency variation with CSV is derived based on the analytical expression of parasitic resonance. Secondly, by employing CSV in control, not only is the switching frequency hopping eliminated, but also the switching cycle corresponds more accurately with the desired cycle. Therefore, an accurate average current control is derived to reduce the current distortion. Thirdly, the CSV is tuned according to a loss estimation, which further improves the efficiency under valley skipping operation. Finally, a 250W prototype is built to verify the proposed control strategy. Experimental results demonstrate that the proposed strategy improves the efficiency by an average level of 0.4% and reduces the input current THD to levels below 3.1% at rated power.

6 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CCChen Chen
Chen Chen
LWLiang Wang
Liang Wang
WWWanyang Wang
Wanyang Wang
RMRun Min
Run Min
QTQiaoling Tong
Qiaoling Tong
Inductor parameter variations often affect the control performance of digital current mode (CM)-controlled buck converters as their high performance relies on accurate converter modeling. However, recent studies have shown that reliably monitoring inductance with current sensors and high-frequency sampling greatly increases the overall cost of this process. To address this issue, an online inductance monitoring method without a current sensor is proposed in this study. First, an inductance calculation model is derived by applying the dynamic characteristics of a buck converter with inductor volt-second and capacitor charge balance principles. The model’s accuracy is guaranteed by considering inductor current switching ripple characteristics. Nevertheless, output capacitor equivalent series resistance (ESR) can degrade the accuracy of the proposed calculation model. Thus, to enhance the tolerance of the inductance calculation model to capacitor ESR, the ESR effect on inductance monitoring is investigated. With the proposed capacitor ESR estimation method, inductance monitoring achieves reliable accuracy, even for a buck converter with high capacitor ESR. The effectiveness of the proposed method is verified by simulations and experiments on a buck converter with digital sensorless current mode (SCM) control.