Nadzhratul Husna

Mrs. Nadzhratul Husna

Institute of Autonomous System for Autonomous Facilities, Universiti Teknologi PETRONAS
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2014 in Computers in Railways XIV
Verified
Conference Paper
Closed access
PDF file
MKM. F. Khamidi
M. F. Khamidi
CGC. Glover
C. Glover
SFS. A. Farhan
S. A. Farhan
Nadzhratul HusnaNadzhratul Husna
Nadzhratul Husna
MNM. F. Nuruddin
M. F. Nuruddin
The objective of this paper is to evaluate the effect of silica aerogel on the thermal conductivity of cement paste for the construction of concrete...

30 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Fouad Ismail IsmailFouad Ismail Ismail
Fouad Ismail Ismail
Syed Ahmad FarhanSyed Ahmad Farhan
Syed Ahmad Farhan
Nasir ShafiqNasir Shafiq
Nasir Shafiq
Nadzhratul HusnaNadzhratul Husna
Nadzhratul Husna
MSMuhammad Taufiq Sharif
Muhammad Taufiq Sharif
AVArul Kamal Veerasenan
Arul Kamal Veerasenan
Silica aerogel possesses an ultra-low thermal conductivity by virtue of its nano-structure. Owing to the fragility of monolithic aerogel, the development and production of aerogel-based insulation materials involve the incorporation of granular aerogel with other materials to form composite materials. In the present study, the application of silica-aerogel-incorporated composite cement paste as render on the roof-top surface is coupled with the installation of a novel silica-aerogel-incorporated composite insulation board below the roof tiles. Control and silica-aerogel-incorporated samples of the composite cement paste and insulation were prepared. Thermal conductivity and strength tests were performed on the samples. A simulation study was performed on a Building Information Model subjected to a tropical climate to project the resultant impact of the cement render coupled with the insulation board on the thermal-energy-efficiency of the roof. For optimization of thermal and strength performances, silica aerogel contents of 4 wt.% and 3 wt.% were selected for the cement render and insulation board, respectively. The projected annual cooling load and energy savings revealed that the application of a 20-mm cement render, coupled with the installation of a 100-mm thick insulation board, is recommended as the optimum roof configuration.

22 April 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Syed Ahmad FarhanSyed Ahmad Farhan
Syed Ahmad Farhan
Fouad Ismail IsmailFouad Ismail Ismail
Fouad Ismail Ismail
OKOsamah Kiwan
Osamah Kiwan
Nasir ShafiqNasir Shafiq
Nasir Shafiq
AZAzni Zain-Ahmed
Azni Zain-Ahmed
AHAfif Izwan Abd Hamid
Afif Izwan Abd Hamid
Modern residential roofs in Malaysia mainly employ red and brown roof tiles due to aesthetic factors and the ability of the roof surface to reflect or retard heat transfer is typically not considered the main priority. The present article reveals the findings of a study on the effect of roof tile colour on heat conduction transfer through roof tiles and ceiling boards, roof-top surface temperature and cooling load. Findings suggest that the selection of white roof tiles significantly reduces the peaks of heat conduction transfer and roof-top surface temperature as well as the values of heat conduction transfer and roof-top surface temperature throughout diurnal profiles, which consequently reduces hours of indoor thermal discomfort and use of air-conditioners in indoor spaces. A decline in peak roof-top surface temperature of up to 16.00 °C that results in annual energy savings of up to 13.14% can be achieved when the roof tile colour is changed from red to white. Further research on the development of solar-reflective paint or coating products that can significantly increase the solar reflectance values of non-white roof tiles are essential to overcome issues related to maintenance difficulties and lack of preference among house buyers towards white roof tiles.

31 March 2012 in Arabian Journal of Geosciences
Verified
Journal Article
Closed access
PDF file
NSNur Aliaa Shafie
Nur Aliaa Shafie
AAAhmad Zaharin Aris
Ahmad Zaharin Aris
Nadzhratul HusnaNadzhratul Husna
Nadzhratul Husna

11 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SRSiti Humairah Abd Rahman
Siti Humairah Abd Rahman
Syed Ahmad FarhanSyed Ahmad Farhan
Syed Ahmad Farhan
YSYon Azwa Sazali
Yon Azwa Sazali
LSLuqmanul Hakim Shafiee
Luqmanul Hakim Shafiee
Nadzhratul HusnaNadzhratul Husna
Nadzhratul Husna
MHMohd Firdaus Habarudin
Mohd Firdaus Habarudin
The present study aimed to investigate the effect of an expandable additive on the compressive strength and linear expansion of geopolymer cement, which is an alternative to ordinary Portland cement, for oil-well cementing. Fly-ash-based geopolymer cement samples, with the addition of slag cement as a strength enhancer, were prepared by using an elastomeric expandable additive (R-additive), which consists of styrene–butadiene rubber with a specific gravity of 0.945, at concentrations of 10%, 15%, 20% and 25% by weight of the solid blend, and cured in a water bath at 60 °C and atmospheric pressure, and a curing chamber at 90 °C and 3000 psi, or approximately 20.68 MPa. Mixability, amount of free water and slurry density were studied, and the effects of the concentration of R-additive on the compressive strength (F) and linear expansion (∆l/l0) of the samples were analyzed. When cured at 60 °C and atmospheric pressure, the highest F of 15.01 MPa was obtained when the concentration of R-additive was 10%, while the highest ∆l/l0 of 0.9985% was obtained when the concentration of R-additive was 25%. An increase in the curing temperature and pressure to 90 °C and 3000 psi (≈20.68 MPa) resulted in the reduction of F from 15.01 to 14.62 MPa and from 10.33 to 9.61 MPa, and the increase in ∆l/l0 from 0.52% to 0.63%, and from 0.99% to 1.32%, when the concentrations of R-additive were 10% and 25%, respectively. The findings suggest that the formulations adopted, which contain R-additive at concentrations ranging from 10% to 25%, fulfilled the requirements of the oil and gas industry.

26 November 2014 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
Nadzhratul HusnaNadzhratul Husna
Nadzhratul Husna
MKMohd Faris Khamidi
Mohd Faris Khamidi
KAKhairun Azizi Azizli
Khairun Azizi Azizli
Syed Ahmad FarhanSyed Ahmad Farhan
Syed Ahmad Farhan
Installation of insulation materials in buildings can reduce the usage of air conditioners by retarding heat flow into the building. Aerogel is one of the best insulation materials with distinctive properties that can replace existing building insulation materials such as fibre glass and polyurethane. However, brittleness of Aerogel makes it difficult to handle and disqualifies its viability as a building insulation material. Reinforcement of Aerogel with binding materials can improve its mechanical and thermal properties to overcome its brittleness. However, only a few studies have been carried out on this area. Furthermore, from the few existing studies, vital information such as thermal conductivity and specific application of the reinforced Aerogel studied were not considered. As an initiative to fill in this research gap, a review on reinforcement of Aerogel is presented.