Paul Leblans

Dr. Paul Leblans

Central Innovation Office, Agfa-Gevaert (Belgium), Mortsel, Flanders, Belgium
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2011 in Materials
Verified
Journal Article
Open access
PDF file
PLPaul Leblans
Paul Leblans
DVDirk Vandenbroucke
Dirk Vandenbroucke
PWPeter Willems
Peter Willems
Computed radiography (CR) uses storage phosphor imaging plates for digital imaging. Absorbed X-ray energy is stored in crystal defects. In read-out the energy is set free as blue photons upon optical stimulation. In the 35 years of CR history, several storage phosphor families were investigated and developed. An explanation is given as to why some materials made it to the commercial stage, while others did not. The photo stimulated luminescence mechanism of the current commercial storage phosphors, BaFBr:Eu2+ and CsBr:Eu2+ is discussed. The relation between storage phosphor plate physical characteristics and image quality is explained. It is demonstrated that the morphology of the phosphor crystals in the CR imaging plate has a very significant impact on its performance.

24 October 2022 in Physica Medica
Verified
Journal Article
Closed access
VVVerdi Vanreusel
Verdi Vanreusel
AGAlessia Gasparini
Alessia Gasparini
FGFederica Galante
Federica Galante
GMGiulia Mariani
Giulia Mariani
MPMatteo Pacitti
Matteo Pacitti
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento

12 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
LBLily Bossin
Lily Bossin
IPIgor Plokhikh
Igor Plokhikh
JCJeppe Brage Christensen
Jeppe Brage Christensen
DGDariusz Jakub Gawryluk
Dariusz Jakub Gawryluk
YKYuuki Kitagawa
Yuuki Kitagawa
EYEduardo Gardenali Yukihara
Eduardo Gardenali Yukihara
The objective of this work is to review and assess the potential of MgB4O7:Ce,Li to fill in the gaps where the need for a new material for optically stimulated luminescence (OSL) dosimetry has been identified. We offer a critical assessment of the operational properties of MgB4O7:Ce,Li for OSL dosimetry, as reviewed in the literature and complemented by measurements of thermoluminescence spectroscopy, sensitivity, thermal stability, lifetime of the luminescence emission, dose response at high doses (>1000 Gy), fading and bleachability. Overall, compared with Al2O3:C, for example, MgB4O7:Ce,Li shows a comparable OSL signal intensity following exposure to ionizing radiation, a higher saturation limit (ca 7000 Gy) and a shorter luminescence lifetime (31.5 ns). MgB4O7:Ce,Li is, however, not yet an optimum material for OSL dosimetry, as it exhibits anomalous fading and shallow traps. Further optimization is therefore needed, and possible avenues of investigation encompass gaining a better understanding of the roles of the synthesis route and dopants and of the nature of defects.

28 June 2001
Verified
Conference Paper
Closed access
PDF file
PLPaul Leblans
Paul Leblans
LSLuc Struye
Luc Struye
PWPeter H G M Willems
Peter H G M Willems
The storage phosphor RbBr:Tl+ can be grown in needles via vacuum deposition. Thanks to reduced lateral light diffusion thick needle screens still offer acceptable resolution. Due to its low intrinsic X-ray absorption, however, a RbBr:Tl+ needle screen does not lead to a better absorption/resolution compromise than a BaFBr1-xIx:Eu2+ powder screen. CsBr:Eu2+ does combine high specific X-ray absorption and the possibility of needle growth. Its blue emission, peaking at 440 nm and near IR stimulation band, with maximum at 685 nm, make it well suited for use in CR systems. Sensitivity and sharpness of a 500 (mu) thick CsBr:Eu2+ needle screen were measured in a flying-spot scanner. The number of photostimulated light quanta per absorbed X-ray quantum is higher than for BaFBr1-xIx:Eu2+. At 70 kVp and 0.5 mm Cu filtration, equal sharpness is obtained for 85% vs. 46% X-ray absorption in BaFBr1-xIx:Eu2+ screens. DQE was measured at 2.5 (mu) Gy, 70 kVp, and 0.5 mm Cu filtration for a CsBr:Eu2+ needle screen in a flying-spot scanner. Up to 3 lp/mm, DQE was 2 times higher than for state-of-the-art CR systems and equal to the DQE claimed for flat panel DR systems, based on a-Si photodiodes combined with a CsI:Tl scintillator layer.

5 October 2023 in Physica Medica
Verified
Journal Article
Closed access
VVVerdi Vanreusel
Verdi Vanreusel
AGAlessia Gasparini
Alessia Gasparini
FGFederica Galante
Federica Galante
GMGiulia Mariani
Giulia Mariani
MPMatteo Pacitti
Matteo Pacitti
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento

25 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
PLPaul Leblans
Paul Leblans
BHBrent van der Heyden
Brent van der Heyden
MAMark Akselrod
Mark Akselrod
JGJo Goossens
Jo Goossens
DVDirk Verellen
Dirk Verellen
Real time radioluminescence fibre-based detectors were investigated for application in proton, helium, and carbon therapy dosimetry. The Al2O3:C probes are made of one single crystal (1 mm) and two droplets of micro powder in two sizes (38 μm and 4 μm) mixed with a water-equivalent binder. The fibres were irradiated behind different thicknesses of solid slabs, and the Bragg curves presented a quenching effect attributed to the nonlinear response of the radioluminescence (RL) signal as a function of linear energy transfer (LET). Experimental data and Monte Carlo simulations were utilised to acquire a quenching correction method, adapted from Birks’ formulation, to restore the linear dose–response for particle therapy beams. The method for quenching correction was applied and yielded the best results for the ‘4 μm’ optical fibre probe, with an agreement at the Bragg peak of 1.4% (160 MeV), and 1.5% (230 MeV) for proton-charged particles; 2.4% (150 MeV/u) for helium-charged particles and of 4.8% (290 MeV/u) and 2.9% (400 MeV/u) for the carbon-charged particles. The most substantial deviations for the ‘4 μm’ optical fibre probe were found at the falloff regions, with ~3% (protons), ~5% (helium) and 6% (carbon).