Philipp Lazen

Mr. Philipp Lazen

Medical University of Vienna, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Analytical Biochemistry
Verified
Journal Article
Open access
GHGilbert Hangel
Gilbert Hangel
ENEva Niess
Eva Niess
PLPhilipp Lazen
Philipp Lazen
PBPetr Bednarik
Petr Bednarik
WBWolfgang Bogner
Wolfgang Bogner
BSBernhard Strasser
Bernhard Strasser
Magnetic Resonance Spectroscopic Imaging (MRSI) of the brain enables insights into the metabolic changes and fluxes in diseases such as tumors, multiple sclerosis, epilepsy, or hepatic encephalopathy, as well as insights into general brain functionality. However, the routine application of MRSI is mostly hampered by very low signal-to-noise ratios (SNR) due to the low concentrations of metabolites, about 10000 times lower than water. Furthermore, MRSI spectra have a dense information content with many overlapping metabolite resonances, especially for proton MRSI. MRI scanners at ultra-high field strengths, like 7 T or above, offer the opportunity to increase SNR, as well as the separation between resonances, thus promising to solve both challenges. Yet, MRSI at ultra-high field strengths is challenged by decreased B0- and B1-homogeneity, shorter T2 relaxation times, stronger chemical shift displacement errors, and aggravated lipid contamination. Therefore, to capitalize on the advantages of ultra-high field strengths, these challenges must be overcome. This review focuses on the challenges MRSI of the human brain faces at ultra-high field strength, as well as the possible applications to this date.

7 October 2023 in Journal of Neurology
Verified
Journal Article
Open access
PDF file
GHGilbert Hangel
Gilbert Hangel
GKGregor Kasprian
Gregor Kasprian
SCStefanie Chambers
Stefanie Chambers
LHLukas Haider
Lukas Haider
PLPhilipp Lazen
Philipp Lazen
Karl RoesslerKarl Roessler
Karl Roessler
Objective: Recently, the 7 Tesla (7 T) Epilepsy Task Force published recommendations for 7 T magnetic resonance imaging (MRI) in patients with pharmaco-resistant focal epilepsy in pre-surgical evaluation. The objective of this study was to implement and evaluate this consensus protocol with respect to both its practicability and its diagnostic value/potential lesion delineation surplus effect over 3 T MRI in the pre-surgical work-up of patients with pharmaco-resistant focal onset epilepsy. Methods: The 7 T MRI protocol consisted of T1-weighted, T2-weighted, high-resolution-coronal T2-weighted, fluid-suppressed, fluid-and-white-matter-suppressed, and susceptibility-weighted imaging, with an overall duration of 50 min. Two neuroradiologists independently evaluated the ability of lesion identification, the detection confidence for these identified lesions, and the lesion border delineation at 7 T compared to 3 T MRI. Results: Of 41 recruited patients > 12 years of age, 38 were successfully measured and analyzed. Mean detection confidence scores were non-significantly higher at 7 T (1.95 ± 0.84 out of 3 versus 1.64 ± 1.19 out of 3 at 3 T, p = 0.050). In 50% of epilepsy patients measured at 7 T, additional findings compared to 3 T MRI were observed. Furthermore, we found improved border delineation at 7 T in 88% of patients with 3 T-visible lesions. In 19% of 3 T MR-negative cases a new potential epileptogenic lesion was detected at 7 T. Conclusions: The diagnostic yield was beneficial, but with 19% new 7 T over 3 T findings, not major. Our evaluation revealed epilepsy outcomes worse than ILAE Class 1 in two out of the four operated cases with new 7 T findings.

26 April 2022 in Cancers
Verified
Journal Article
Open access
PDF file
GHGilbert Hangel
Gilbert Hangel
PLPhilipp Lazen
Philipp Lazen
SSSukrit Sharma
Sukrit Sharma
BHBarbara Hristoska
Barbara Hristoska
CCCornelius Cadrien
Cornelius Cadrien
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
(1) Background: Recent developments in 7T magnetic resonance spectroscopic imaging (MRSI) made the acquisition of high-resolution metabolic images in clinically feasible measurement times possible. The amino acids glutamine (Gln) and glycine (Gly) were identified as potential neuro-oncological markers of importance. For the first time, we compared 7T MRSI to amino acid PET in a cohort of glioma patients. (2) Methods: In 24 patients, we co-registered 7T MRSI and routine PET and compared hotspot volumes of interest (VOI). We evaluated dice similarity coefficients (DSC), volume, center of intensity distance (CoI), median and threshold values for VOIs of PET and ratios of total choline (tCho), Gln, Gly, myo-inositol (Ins) to total N-acetylaspartate (tNAA) or total creatine (tCr). (3) Results: We found that Gln and Gly ratios generally resulted in a higher correspondence to PET than tCho. Using cutoffs of 1.6-times median values of a control region, DSCs to PET were 0.53 ± 0.36 for tCho/tNAA, 0.66 ± 0.40 for Gln/tNAA, 0.57 ± 0.36 for Gly/tNAA, and 0.38 ± 0.31 for Ins/tNAA. (4) Conclusions: Our 7T MRSI data corresponded better to PET than previous studies at lower fields. Our results for Gln and Gly highlight the importance of future research (e.g., using Gln PET tracers) into the role of both amino acids.

26 February 2024 in Cancers
Verified
Journal Article
Open access
PDF file
PLPhilipp Lazen
Philipp Lazen
PCPedro De Lima Cardoso
Pedro De Lima Cardoso
SSSukrit Sharma
Sukrit Sharma
CCCornelius Cadrien
Cornelius Cadrien
TRThomas Roetzer-Pejrimovsky
Thomas Roetzer-Pejrimovsky
GHGilbert Hangel
Gilbert Hangel
This paper investigated the correlation between magnetic resonance spectroscopic imaging (MRSI) and magnetic resonance fingerprinting (MRF) in glioma patients by comparing neuro-oncological markers obtained from MRSI to T1/T2 maps from MRF. Data from 12 consenting patients with gliomas were analyzed by defining hotspots for T1, T2, and various metabolic ratios, and comparing them using Sørensen–Dice similarity coefficients (DSCs) and the distances between their centers of intensity (COIDs). The median DSCs between MRF and the tumor segmentation were 0.73 (T1) and 0.79 (T2). The DSCs between MRSI and MRF were the highest for Gln/tNAA (T1: 0.75, T2: 0.80, tumor: 0.78), followed by Gly/tNAA (T1: 0.57, T2: 0.62, tumor: 0.54) and tCho/tNAA (T1: 0.61, T2: 0.58, tumor: 0.45). The median values in the tumor hotspot were T1 = 1724 ms, T2 = 86 ms, Gln/tNAA = 0.61, Gly/tNAA = 0.28, Ins/tNAA = 1.15, and tCho/tNAA = 0.48, and, in the peritumoral region, were T1 = 1756 ms, T2 = 102 ms, Gln/tNAA = 0.38, Gly/tNAA = 0.20, Ins/tNAA = 1.06, and tCho/tNAA = 0.38, and, in the NAWM, were T1 = 950 ms, T2 = 43 ms, Gln/tNAA = 0.16, Gly/tNAA = 0.07, Ins/tNAA = 0.54, and tCho/tNAA = 0.20. The results of this study constitute the first comparison of 7T MRSI and 3T MRF, showing a good correspondence between these methods.

8 January 2025 in NeuroImage
Verified
Journal Article
Open access
LHLukas Hingerl
Lukas Hingerl
BSBernhard Strasser
Bernhard Strasser
SSSimon Schmidt
Simon Schmidt
KEKorbinian Eckstein
Korbinian Eckstein
GGGuglielmo Genovese
Guglielmo Genovese
MMMałgorzata Marjańska
Małgorzata Marjańska
Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.5 T whole-body MR system. Employing a custom-built 16-channel transmit and 80-channel receive MR coil at 10.5 T, we conducted MRSI acquisitions in six healthy volunteers to map metabolic compounds in the human cerebrum in vivo. Three MRSI protocols with different matrix sizes and scan times (4.4 × 4.4 × 4.4 mm³: 10 min, 3.4 × 3.4 × 3.4 mm³: 15 min, and 2.75×2.75×2.75 mm³: 25 min) were tested. Concentric ring trajectories were utilized for time-efficient encoding of a spherical 3D k-space with ∼4 kHz spectral bandwidth. B0/B1 shimming was performed based on respective field mapping sequences and anatomical T1-weighted MRI were obtained. By combining the benefits of an ultra-high-field system with the advantages of free-induction-decay (FID-)MRSI, we present the first metabolic maps acquired at 10.5 T in the healthy human brain at both high (voxel size of 4.4³ mm³) and ultra-high (voxel size of 2.75³ mm³) isotropic spatial resolutions. Maps of 13 metabolic compounds (aspartate, choline compounds and creatine + phosphocreatine, γ-aminobutyric acid (GABA), glucose, glutamine, glutamate, glutathione, myo-inositol, scyllo-inositol, N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), taurine) and macromolecules were obtained individually. The spectral quality was outstanding in the parietal and occipital lobes, but lower in other brain regions such as the temporal and frontal lobes. The average total NAA (tNAA = NAA + NAAG) signal-to-noise ratio over the whole volume of interest was 12.1± 8.9 and the full width at half maximum of tNAA was 24.7± 9.6 Hz for the 2.75 × 2.75 × 2.75 mm³ resolution. The need for an increased spectral bandwidth in combination with spatio-spectral encoding imposed significant challenges on the gradient system, but the FID approach proved very robust to field inhomogeneities of ∆B0 = 45 ± 38 Hz (frequency offset ± spatial STD) and B1+ = 65 ± 11° within the MRSI volume of interest. These preliminary findings highlight the potential of 10.5 T MRSI as a powerful imaging tool for probing cerebral metabolism. By providing unprecedented spatial and spectral resolution, this technology could offer a unique view into the metabolic intricacies of the human brain, but further technical developments will be necessary to optimize data quality and fully leverage the capabilities of 10.5 T MRSI.