Serena Concetta Rita Reina

Dr. Serena Concetta Rita Reina

Department of Medical, Surgical Sciences and Advanced Technologies "GF Ingrassia" (DGFI),, University of Catania, Catania, Sicilia, Italy
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2024 in ACS Medicinal Chemistry Letters
Verified
Journal Article
Closed access
SSSilvia Salerno
Silvia Salerno
EBelisabetta barresi
elisabetta barresi
MRMichele Roggia
Michele Roggia
BNBenito Natale
Benito Natale
SMSimona Marzano
Simona Marzano
STSabrina Taliani
Sabrina Taliani

16 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Roberta FarinaRoberta Farina
Roberta Farina
Silvia ScaleseSilvia Scalese
Silvia Scalese
Alessandra AlbertiAlessandra Alberti
Alessandra Alberti
SPStefania M. S. Privitera
Stefania M. S. Privitera
GCGiuseppe Emanuele Capuano
Giuseppe Emanuele Capuano
Sebania LibertinoSebania Libertino
Sebania Libertino
Nitrite (NO2−) has long been recognized as a contaminant of concern due to its detrimental effects on both human health and the environment. As a result, there is a continuing need to develop sensitive, real-time, low-cost, and portable systems for the accurate detection of trace levels of NO2− in drinking water. We present a novel, low-cost, and easy-to-fabricate amperometric sensor designed for detecting low concentrations of NO2− in drinking water. The fabrication technique involves the electrodeposition of manganese and copper oxides onto a carbon working electrode. CuO and MnO2 act synergistically as efficient catalysts for the electrooxidation of nitrite to nitrate (NO3−) thanks to their complementary redox properties. The resulting sensor exhibits high catalytic activity toward the electrooxidation of NO2−, with a sensitivity of 10.83 μA/µM, a limit of detection (LOD) of 0.071 µM, and a good linear dynamic concentration range (0.2–60 µM). The sensor’s performance was evaluated against potential interfering analytes (NO3−, Cl−, NH4+, and NH2Cl), all of which showed negligible interference. Reproducibility (maximum standard deviation 2.91%) and repeatability (usable up to three times) were also evaluated.

14 September 2024 in Journal of Chemical Information and Modeling
Verified
Journal Article
Closed access
MRMichele Roggia
Michele Roggia
BNBenito Natale
Benito Natale
GAGiorgio Amendola
Giorgio Amendola
NGNicola Grasso
Nicola Grasso
SMSalvatore Di Maro
Salvatore Di Maro
SCSandro Cosconati
Sandro Cosconati

24 September 2025
Verified
Conference Paper
Closed access
Domenico CorsoDomenico Corso
Domenico Corso
GSGiuseppe Andrea Screpis
Giuseppe Andrea Screpis
GCGiuseppe Emanuele Capuano
Giuseppe Emanuele Capuano
Roberta FarinaRoberta Farina
Roberta Farina
SRSerena Concetta Rita Reina
Serena Concetta Rita Reina
Sebania LibertinoSebania Libertino
Sebania Libertino
This study presents a compact and highly sensitive optoelectronic biosensing system that integrates genetically engineered Escherichia coli bacteria with a Silicon Photomultiplier-based detection module for monitoring mercury in aquatic environments. The engineered bacteria produce bioluminescent signals in response to mercury exposure, with light intensity directly proportional to the concentration of bioavailable metal ions. By combining the high photon detection efficiency and low-noise performance of Silicon Photomultipliers with a custom-built acquisition interface, our system enables real-time monitoring of pollutants at trace levels. Additionally, the multi-chamber configuration supports simultaneous measurements under different conditions, facilitating direct biosensor calibration and enhancing the reliability of statistical analysis. Measurements demonstrate a Limit of Detection of 0.12 μg/L, eight times below current environmental regulatory thresholds, and a dynamic range spanning about two orders of magnitude. Compared to a conventional laboratory-grade luminometer, our system achieves equivalent sensitivity while offering significant advantages in terms of portability, cost, and remote control. These features highlight its strong potential for environmental monitoring and risk assessment.

24 September 2025
Verified
Conference Paper
Closed access
GCGiuseppe Emanuele Capuano
Giuseppe Emanuele Capuano
GSGiuseppe Andrea Screpis
Giuseppe Andrea Screpis
Domenico CorsoDomenico Corso
Domenico Corso
FMFabio Matera
Fabio Matera
Roberta FarinaRoberta Farina
Roberta Farina
Sebania LibertinoSebania Libertino
Sebania Libertino
This work presents the design and optimization of a miniaturizable, high-sensitivity system for real-time detection of adenosine triphosphate (ATP)-the primary energy carrier in biological systems-in water samples. Detection was based on the chemiluminescent ATP-luciferin driven reaction, monitored using a silicon photomultiplier (SiPM). Three different set-up configurations were investigated, focusing on the effects of reaction chamber size and total solution volume. The system achieved a minimum detectable ATP concentration of 0.05 nM, with a limit of detection (LoD) of 0.03 nM and a sensitivity of 11.9 A/M.

24 September 2025
Verified
Conference Paper
Closed access
GSGiuseppe Andrea Screpis
Giuseppe Andrea Screpis
GCGiuseppe Emanuele Capuano
Giuseppe Emanuele Capuano
Domenico CorsoDomenico Corso
Domenico Corso
Roberta FarinaRoberta Farina
Roberta Farina
SRSerena Concetta Rita Reina
Serena Concetta Rita Reina
Sebania LibertinoSebania Libertino
Sebania Libertino
In this work, we present an innovative system for the rapid detection of bacterial contamination in water samples, exploiting chemiluminescence reaction in the presence of bacterial adenosine triphosphate (ATP). It is formed by a closed box in which reagents and ATP from water samples are put in a spectrophotometric-grade quartz cuvette on a silicon photomultiplier (SiPM) that converts the photons revealed into electrical signals. A commercial kit for bacterial load detection in water samples employing ATP chemiluminescent reaction was tested, and its filtration and lysis efficiencies were assessed. A comparison between the new system and the luminometer, the standard device for chemiluminescence detection, was then conducted. Firstly, calibration curves for both systems were obtained using different ATP concentrations, resulting in a Limit of Detection (LoD) of 0.03 nM for the SiPM-based system and 0.01 nM for the luminometer. Afterwards, water samples artificially contaminated with E. coli were prepared to compare the detection efficiency of both systems using the commercial kit for sample processing. A cultural method analysis was also conducted to validate the obtained results. ATP concentrations derived from the three detection strategies showed great consistency, underlying the high sensitivity of the new low-cost, miniaturizable and potentially remotely controlled system developed.